غير متوفر في المخزون

MicroBT

MicroBT Whatsminer M73 470TH

نموذج: Whatsminer M73

جديد

470 TH/s hydro cooled SHA-256 Bitcoin miner at 7,200W and 15.32 J/TH efficiency, the base bin of MicroBT's M73 rack mount hydro tier in the M70 generation. Manufacturer headline spec runs 14.5 J/TH across the broader 470 to 500 TH/s binning range per Apexto and Zeus Mining. Lowest per unit acquisition cost in the M73 lineup. Positioned below the mid bin M73S (500 to 540 TH/s at 13.5 J/TH) and top bin M73S+ (540 to 600 TH/s at 12.5 J/TH) across an identical 4U rack mount chassis and water cooling architecture. 10 M73 units per 42U rack produce 4.7 PH/s at 72 kW. Same 483 x 663 x 86 mm chassis at 29.5 kg. 380 to 480V three phase industrial power. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

470 TH/s 7200W SHA-256 15.32 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

حقيقي

الأجهزة المُختبرة

في جميع أنحاء العالم

الشحن العالمي

دعم

خبراء التعدين

معدل التجزئة

470 TH/s

قوة

7200 W

الكفاءة

15.32 J/TH

ضوضاء

75 dB

عوائد التعدين المقدرة

استنادًا إلى سعر البيتكوين الحالي وصعوبة الشبكة. للاشارة فقط.

نقطة زمنية يوميًا أسبوعي شهريًا
الدخل
$47.42 $331.94 $1,422.60
الكهرباء
-$13.82 -$96.74 -$414.60
ربح
$33.59 $235.13 $1,007.70

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 10, 2026. Estimates at $0.08/kWh.

المواصفات الكاملة

معدل التجزئة 470 TH/s
استهلاك الطاقة 7200 W
الكفاءة 15.32 J/TH
الخوارزمية SHA-256
نموذج Whatsminer M73
سنة الإصدار ديسمبر 2025
مستوى الضوضاء 75 dB
الأبعاد 483 x 663 x 86mm
وزن 29.5 kg
الجهد AC 380-480V
واجهات Ethernet
درجة حرارة التشغيل 5 - 45 °C
الرطوبة 5 - 95 %
نوع التبريد Hydro
صيغة الحامل 4U

ماذا يوجد في الصندوق

Whatsminer M73
وحدة تزويد الطاقة (PSU)
كابلات الطاقة
دليل البدء السريع

قد تختلف المحتويات حسب الدفعة. العناصر الدقيقة مذكورة في تأكيد الطلب.

إعداد سريع

1

Connect PSU to miner and plug into the outlet

2

اتصل بكابل الإثيرنت إلى الموجّه أو المفتاح

3

ابحث عن عنوان IP للمنجم عبر إدارة الموجه أو أداة مسح IP

4

افتح واجهة الويب، أدخل عنوان المسبح والمحفظة — ابدأ التعدين

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

تفاصيل المنتج

MicroBT Whatsminer M73 470 TH/s Hydro Cooled 4U Rack Mount Bitcoin Miner: Base Bin Economics, Specifications, and Deployment Guide

The Whatsminer M73 is the base bin entry of MicroBT's M73 rack mount hydro tier in the M70 generation, positioned below the M73S mid bin (500 to 540 TH/s at 13.5 J/TH) and M73S+ top bin (540 to 600 TH/s at 12.5 J/TH). MillionMiner rated spec: 470 TH/s and 15.32 J/TH. Manufacturer headline per Apexto, Zeus Mining, and X ON Mining documents the broader binning range at 470 to 500 TH/s and 14.5 J/TH efficiency across the platform. Base bin exists to serve volume buyers whose binding constraint is hardware budget rather than operating efficiency. When a facility has fixed capital allocation for hardware and the goal is to fill available rack capacity with maximum unit count, the M73 at the lowest per unit acquisition cost fits more machines in the rack than either higher bin. Whether this strategy wins total fleet economics depends on the arithmetic between acquisition cost savings and lifetime efficiency penalty. The efficiency comparison is quantifiable. M73 at 15.32 J/TH versus M73S+ at 13.33 J/TH (or manufacturer headline 12.5 J/TH). At $0.04 per kWh industrial rates, the per unit daily electricity difference runs roughly $0.30. At $0.08 per kWh: approximately $0.55 daily per unit. Across a 10 unit rack, those differences compound to $3 to $5.50 daily. Over a 3 year deployment horizon at $0.06 per kWh, accumulated efficiency gap totals approximately $5,500 per rack between M73 and M73S+. Whether this justifies the top bin acquisition premium depends on the specific price differential at your supplier. Base bin chips also run at lower clock frequencies than top grade, which reduces per chip thermal stress over extended operational life. Some fleet operators deliberately choose base bin specifically for multi year deployments where longevity trumps peak efficiency. All M73 variants use physically identical silicon from the same production run, so structural differences are nonexistent. Only the tested performance grade differs. The M73 series rack mount hydro approach avoids immersion tank infrastructure while capturing liquid cooling advantages. Water flows through internal channels in a sealed 4U rack mount chassis and carries heat to an external cooling loop. Units install in standard 19 inch server racks alongside any other data center equipment. Closed loop water cooling uses off the shelf pumps, standard plumbing fittings, and water glycol coolant. Compared to air cooled Bitcoin miners at similar hashrate class, the M73 delivers lower noise, higher sustained output under load, and typically longer component life because chips operate at consistent temperatures. Rack density works out to 10 M73 units per 42U rack (factoring cooling manifold space and cable management) producing 4.7 PH/s at 72 kW per rack. Same rack power as M73S+ (5.4 PH/s) and M73S (5 PH/s). Mix bins within racks based on acquisition cost optimization. Power infrastructure: 380 to 480V three phase commercial or industrial service. At 415V three phase the M73 draws approximately 17 amps per phase. At 480V: approximately 15 amps per phase. Fits within standard 20 amp commercial breakers. Same three phase requirements as the entire M73 series. Bitcoin mining economics at 470 TH/s: MillionMiner's $0.08 per kWh onsite calculator shows $15.32 daily revenue, $13.82 electricity, $1.50 net profit per day. Tight margins at standard rates. At $0.04 per kWh industrial rates: $6.91 daily electricity, netting $8 to $9 daily profit per unit. A 10 unit M73 rack produces $80 to $90 daily net profit at $0.04 per kWh. Economic viability requires industrial electricity below $0.05 per kWh. 483 x 663 x 86 mm at 29.5 kg. Ethernet 10/100M management through standard Whatsminer firmware. 5 to 45 degrees Celsius operating range at 5 to 95 percent humidity. PSU ships included. 360 day MicroBT manufacturer warranty. Free DDP delivery worldwide from MillionMiner.

MicroBT Whatsminer M73 470 TH/s: Base Bin Entry to the M73 Rack Mount

The M73 is the volume fleet pick in MicroBT's M73 rack mount hydro tier.
Same 7,200W power draw as the M73S and M73S+, same 4U rack mount chassis, same water
cooling architecture, same 380 to 480V three phase requirements. Chip binning grade and
correspondingly lower per unit acquisition cost differentiate the variants.
MillionMiner rated spec: 470 TH/s at 15.32 J/TH. Manufacturer headline per Apexto and Zeus
Mining: 470 to 500 TH/s across the binning range at 14.5 J/TH efficiency. Base bin exists for
operators whose binding constraint is hardware budget rather than operating efficiency. A 10
unit M73 rack produces 4.7 PH/s at 72 kW versus 5.4 PH/s from an equivalent M73S+ rack, at
meaningfully lower acquisition cost per unit.
Base bin silicon also runs at lower clock frequencies than top grade, which reduces per chip
thermal stress over extended operational life. Some fleet operators deliberately choose base bin
for multi year deployments where longevity matters alongside peak efficiency. Combined with
lower acquisition cost, this makes the M73 a defensible fleet strategy rather than just a budget
compromise.
Rack mount hydro approach avoids immersion tank infrastructure while capturing liquid cooling
advantages: lower noise than air cooled equivalents, higher sustained hashrate, longer
component life. Standard 19 inch server racks, off the shelf pumps, water glycol coolant.

هل تحتاج إلى مساعدة في الاختيار؟

يمكن لخبرائنا في التعدين مساعدتك في العثور على الأجهزة المثالية لمعدنك الخاص وميزانيتك.

Whatsminer M73 470 TH/s Hydro 4U Bitcoin Miner

Base bin entry to MicroBT's M73 rack mount hydro tier. MillionMiner rated
spec: 470 TH/s at 7,200W and 15.32 J/TH. Manufacturer headline at 14.5 J/TH across the 470
to 500 TH/s binning range per Apexto and Zeus Mining. Lowest per unit acquisition cost in the
M73 lineup for volume fleet buyers whose binding constraint is hardware budget rather than
operating efficiency. 10 units per 42U rack produce 4.7 PH/s at 72 kW. Base bin chips run at
lower frequencies than top grade, potentially extending component life over multi year
deployments. Same 4U chassis, water cooling architecture, and 380 to 480V three phase
requirements as the M73S and M73S+. 483 x 663 x 86 mm at 29.5 kg. Water glycol closed loop
cooling in standard 19 inch server racks.

470 TH/s Volume Fleet Hydro Entry

Base bin of the M73 rack mount hydro tier at lowest per unit acquisition cost. Maximum units per hardware budget.

Same Chassis and Silicon as Higher Bins

Identical 4U chassis, water cooling, and production silicon as M73S and M73S+. Only testing grade differs. Mix bins freely within racks.

Lower Frequencies, Potentially Longer Life

Base grade chips run at lower clock speeds, reducing per chip thermal stress. Defensible choice for multi year deployments prioritizing longevity.

Request a Bitcoin Miner Hosting Quote

4.7
نجمة نجمة نجمة نجمة نجمة

4.7/5 Verified on Trustpilot

  • ظرف 30,000+ miners hosted since 2020
  • مؤقت Trusted by 1,200+ customers globally
آيزو صُنع في ألمانيا تراستبيول
تقييم جوجل

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

عمال المناجم

عامل منجم

استضافة

استضافة

الأسئلة الشائعة

الأسئلة الشائعة

The M73 produces 470 TH/s of SHA-256 hashrate at 7,200W and 15.32 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Apexto, Zeus Mining, and X ON Mining document the broader binning range at 470 to 500 TH/s and 14.5 J/TH efficiency. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output depends on batch binning, coolant temperature, and operating conditions.

Same 7,200W rated power draw across all three variants. Same 4U chassis, water cooling architecture, and 380 to 480V three phase requirements. Hashrate and efficiency differences come from chip binning. M73 base (this product): 470 to 500 TH/s at 14.5 J/TH. M73S mid: 500 to 540 TH/s at 13.5 J/TH. M73S+ top: 540 to 600 TH/s at 12.5 J/TH. The M73 trades 13 percent hashrate versus the M73S+ for correspondingly lower acquisition cost. For operators whose binding constraint is hardware budget rather than operating efficiency, the M73 puts more units in the rack per dollar of capital spent.

Three scenarios favor the M73. First: hardware budget is the binding constraint rather than electricity cost, common in early stage facility buildouts. Second: deployment horizon is short enough (under 2 years) that acquisition cost savings outweigh lifetime efficiency penalty. Third: electricity rate is cheap enough (below $0.04 per kWh) that the daily efficiency gap between bins is small in absolute dollar terms. If none of these apply, higher bin options typically win on total lifetime fleet economics.

لا. رقاقات قاعدة العلبة ليست من تصنيع أدنى جودة. فهي تأتي من نفس شرائح السيليكون، ونفس خط الإنتاج، ونفس تصميم الشريحة مثل العلبة العليا. فقط درجة الأداء المختبرة تختلف أثناء تصنيف الجودة بعد التصنيع. قد تدوم رقاقات العلبة الأساسية فعليًا لفترة أطول من العلبة العليا في حالات التDeployment الممتدة، لأن تردد الساعة المنخفض يقلل من الإجهاد الحراري لكل شريحة. بالنسبة لنDeployات لعدة سنوات حيث تهم مدة عمر الأجهزة بجانب تكلفة الشراء، يختار بعض مشغلي الأساطيل عمدًا سيليكون العلبة الأساسية.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 17 amps per phase at 7,200W continuous draw. At 480V three phase: approximately 15 amps per phase. Fits within standard 20 amp commercial breakers with headroom. Same three phase requirements as the entire M73 series.

Closed loop water circulation with off the shelf components. Required: circulation pumps sized for total fleet flow rate, standard plumbing fittings, water glycol coolant mixture, external heat rejection through dry coolers or water to water heat exchangers, and inline filtration. Coolant volume scales roughly 2 to 4 liters per unit plus system reservoir capacity. Each M73 adds approximately 24,570 BTU per hour of thermal load. Uses standard data center cooling equipment from any industrial supplier.

A standard 42U rack holds 10 M73 units producing 4.7 PH/s at 72 kW per rack. The M73S rack produces 5 PH/s at the same 72 kW. The M73S+ rack produces 5.4 PH/s. Mix bins within racks based on acquisition cost optimization. Compare against immersion alternatives or air cooled options before committing to facility architecture.

At MillionMiner's $0.08 per kWh onsite calculator: $15.32 daily revenue, $13.82 electricity, $1.50 net profit per day. Margins are tight at standard rates. At $0.07 per kWh industrial rates: approximately $12.10 daily electricity against similar revenue. At $0.04 per kWh negotiated industrial rates: $6.91 daily electricity, netting $8 to $9 daily profit per unit. A 10 unit M73 rack produces $80 to $90 daily net profit at $0.04 per kWh. Economic viability requires industrial electricity below $0.05 per kWh.

أي عملة مشفرة باستخدام إثبات العمل SHA-256. البيتكوين (BTC) هو الهدف الأساسي. تشمل العملات المتوافقة الأخرى بيتكوين كاش (BCH)، بيتكوين إس في (BSV)، فركتال بيتكوين (FB)، وDigiByte (DGB سلسلة SHA-256). التعدين المدمج للبيتكوين إلى جانب BCH وBSV من خلال تجمعات الدعم مثل ViaBTC وF2Pool يضيف دخلًا ثانويًا هامشيًا دون تقليل مساهمة معدل تجزئة البيتكوين.

شغل حساب تكلفة الاستحواذ مقابل التوفير اليومي في الكهرباء باستخدام تسعير المورد الخاص بك. نموذج الفجوة في سعر الوحدة بين الصناديق مقابل التوفير اليومي في الكفاءة عند معدل الكهرباء الخاص بك عبر فترة النشر المتوقعة لديك. إذا كانت الفجوة في سعر الوحدة بين M73 و M73S+ أقل من $600 لدى موردك، فإن الترقية إلى الصندوق الأعلى عادةً ما تكون الخيار الأفضل عند $0.06 لكل كيلوواط ساعة بأسعار صناعية على مدى ثلاث سنوات من النشر. عند وجود فجوات سعرية أصغر، فإن الصناديق الأعلى دائمًا ما تربح. عند وجود فجوات أكبر، يقوى دور الـ M73. بدلاً من ذلك، امزج بين الصناديق داخل نفس الحامل: الغالبية من M73 لتحقيق الكفاءة الرأسمالية، وبعض وحدات M73S+ حيث تكون الكفاءة أكثر أهمية.

Yes. All three M73 variants share identical 4U chassis, water cooling connector design, power requirements, and Whatsminer firmware. Mix bins freely within racks based on fleet deployment strategy. Common pattern: majority M73 units for capital efficiency with some higher bin units in specific slots. Fleet management handles mixed bin deployments transparently through unified Whatsminer firmware dashboards.

نشر صناعي مع بنية تحتية للطاقة ثلاثية الطور وتبريد بالماء. الخطوة الأولى: تثبيت خدمة كهربائية ثلاثية الطور بجهد 380 إلى 480 فولت. الخطوة الثانية: تثبيت وتشغيل حلقة تبريد بالماء تشمل المضخات والسباكة والمبردات الجافة. الخطوة الثالثة: تركيب وحدات M73 على رفوف قياسية بمقاس 19 إنش وربط وصلات الإدخال / الإخراج للمياه. التحقق من عدم وجود تسربات قبل التشغيل. الخطوة الرابعة: توصيل طاقة مزود الطاقة وإدارة الإيثرنت. الخطوة الخامسة: التشغيل، والسماح بتثبيت تدفق المبرد، العثور على عنوان IP لكل جهاز تعدين عبر DHCP، تكوين عنوان تجمع التعدين الرابط عبر واجهة ويب Whatsminer، والتحقق من أن معدل التجزئة يصل إلى أكثر من 456 تيراهاش في الثانية خلال 15 إلى 20 دقيقة لكل وحدة.

Water cooling maintenance. Weekly visual inspection of fittings for leaks or corrosion. Monthly coolant quality testing. Every 12 to 24 months full coolant replacement. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Hashboard failure rates on hydro units run lower than air cooled because chips operate at consistent temperatures. Water cooling maintenance is simpler than immersion fluid management because water glycol is cheaper and more widely available than dielectric fluid.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts. For fleet deployments above 4.7 PH/s (equivalent to 10+ M73 units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

No. The M73 requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V 20A circuits. For high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage, and operation outside the 5 to 45 degree Celsius range. Warranty coverage is identical across all M73 bin variants.

نعم. تدير شركة مليونMiner مرافق استضافة مُدارة مزودة بطاقة صناعية ثلاثية المرحلة وبنية تبريد مائي قادرة على دعم عمليات نشر M73. يُلغي الاستضافة المُدارة من خلال عمليات النشر الموجودة فيها تكاليف رأس مال للبنية التحتية للمرفق. غالبًا ما تتفوق الاستضافة الاحترافية بأسعار صناعية متفاوض عليها على الاستضافة الذاتية عندما يتم حساب جميع تكاليف البنية التحتية. تواصل مع قسم المبيعات في مليونMiner عبر زر "احصل على عرض سعر" للحصول على أسعار الاستضافة، وتوافر السعة، والجداول الزمنية للنشر.

بشكل عام لا، وربما بشكل إيجابي. تعتمد شرائح التصنيف الأساسي على ترددات ساعة أقل من تلك المستخدمة في السيليكون عالي التصنيف، مما يقلل الضغط الحراري على كل شريحة خلال عمر التشغيل الممتد. يختار بعض مشغلي الأسطول عمدًا التصنيف الأساسي لنشرات متعددة السنوات حيث يكون متانة الأجهزة مهمة إلى جانب الكفاءة القصوى. الحجّة المضادة: جميع نسخ M73 تستخدم سيليكونًا متطابقًا من نفس الدفعة الإنتاجية، لذلك غالبًا ما تكون فروق متانة الأجهزة الأساسية طفيفة عمليًا. الفروق في الاعتمادية بين التصنيفات صغيرة مقارنة بالفروق بين طرق التبريد (الهيدروليكي مقابل الغمر مقابل الهواء).

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 7.2 kW: electricity at $5,045 at $0.08 per kWh, $2,522 at $0.04 per kWh industrial rates, water glycol coolant maintenance ($100 to $300 per unit annually), spare parts. Water cooling infrastructure CapEx runs meaningfully lower than immersion tank systems.

Within the M73 rack mount hydro tier: the Whatsminer M73S at 500 to 540 TH/s is the mid bin upgrade path, and M73S+ at 540 to 600 TH/s is the top bin option for operators prioritizing efficiency. Cross cooling at MicroBT: immersion variants M76 and M78 series cover alternative liquid cooling for facilities with tank infrastructure, M79 and M79S cover high power hydro tier. Cross brand hydro: the Bitmain Antminer S23 Hyd 3U at 1.16 PH/s provides vendor diversification at higher power tier. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining. MillionMiner's ASIC hosting service accepts M73 units at negotiated industrial electricity rates.

Get a Quote