540 TH/s hydro cooled SHA-256 Bitcoin miner at 7,200W and 13.33 J/TH efficiency, the top bin of MicroBT's M73 rack mount hydro tier in the M70 generation. Manufacturer headline specs per Blockspace Media and Hashrate Index document the broader binning range at 540 to 600 TH/s with 12.5 J/TH leading efficiency rating, tying the M73S+ with the M76S+ for best efficiency across the entire M70 generation. Overclock mode scales to 10,000W for higher output. Closed loop water cooling in a 4U rack mount chassis for standard 19 inch server racks, avoiding the specialized dielectric fluid and custom tank infrastructure of immersion approaches. 10 M73S+ units per 42U rack produce 5.4 PH/s at 72 kW. 483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase industrial power. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

540 TH/s 7200W SHA-256 13.33 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

حقيقي

الأجهزة المُختبرة

في جميع أنحاء العالم

الشحن العالمي

دعم

خبراء التعدين

معدل التجزئة

540 TH/s

قوة

7200 W

الكفاءة

13.33 J/TH

ضوضاء

75 dB

عوائد التعدين المقدرة

استنادًا إلى سعر البيتكوين الحالي وصعوبة الشبكة. للاشارة فقط.

نقطة زمنية يوميًا أسبوعي شهريًا
الدخل
$52.61 $368.27 $1,578.30
الكهرباء
-$13.82 -$96.74 -$414.60
ربح
$38.78 $271.46 $1,163.40

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 10, 2026. Estimates at $0.08/kWh.

المواصفات الكاملة

معدل التجزئة 540 TH/s
استهلاك الطاقة 7200 W
الكفاءة 13.33 J/TH
الخوارزمية SHA-256
نموذج Whatsminer M73S+
سنة الإصدار ديسمبر 2025
مستوى الضوضاء 75 dB
الأبعاد 483 x 663 x 86mm
وزن 29.5 kg
الجهد AC 380-480V
واجهات Ethernet
درجة حرارة التشغيل 5 - 45 °C
الرطوبة 5 - 95 %
نوع التبريد Hydro
صيغة الحامل 4U

ماذا يوجد في الصندوق

Whatsminer M73S+
وحدة تزويد الطاقة (PSU)
كابلات الطاقة
دليل البدء السريع

قد تختلف المحتويات حسب الدفعة. العناصر الدقيقة مذكورة في تأكيد الطلب.

إعداد سريع

1

Connect PSU to miner and plug into the outlet

2

اتصل بكابل الإثيرنت إلى الموجّه أو المفتاح

3

ابحث عن عنوان IP للمنجم عبر إدارة الموجه أو أداة مسح IP

4

افتح واجهة الويب، أدخل عنوان المسبح والمحفظة — ابدأ التعدين

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

تفاصيل المنتج

MicroBT Whatsminer M73S+ 540 TH/s Hydro Cooled 4U Rack Mount Bitcoin Miner: Efficiency Leader Specifications and Deployment Guide

The Whatsminer M73S+ is the top bin of MicroBT's M73 rack mount hydro tier and co leader on efficiency across the entire M70 generation. MillionMiner rated spec: 540 TH/s at 7,200W and 13.33 J/TH. Manufacturer headline per Blockspace Media and Hashrate Index documents the broader binning range at 540 to 600 TH/s with 12.5 J/TH leading efficiency rating, tying the M73S+ with the M76S+ immersion variant for best efficiency across the entire generation. Overclock mode scales to 10,000W for approximately 600 TH/s peak output. The cooling architecture distinguishes the M73 series from MicroBT's other hydro options. Unlike immersion variants that submerge chips in dielectric fluid, the M73S+ uses closed loop water cooling. Water flows through internal channels in a sealed 4U rack mount chassis and carries heat to an external cooling loop. Units install in standard 19 inch server racks alongside any other data center equipment. No immersion tanks. No dielectric fluid. No custom tank infrastructure. Just water lines and standard server racking. Rack density works out to 10 M73S+ units per 42U rack (factoring space for cooling manifolds and cable management) producing 5.4 PH/s at 72 kW per rack. Compare this against immersion alternatives: a 100 kW panel with M76S+ units produces 7,410 TH/s in tanks requiring specialized infrastructure, versus a 42U rack with M73S+ units producing 5,400 TH/s in standard server racks requiring only water lines and off the shelf cooling equipment. The infrastructure tradeoff favors hydro for facilities already operating water cooled data center equipment, and favors immersion for dedicated mining facilities purpose built around tanks. Water cooling infrastructure requirements: closed loop water circulation using off the shelf pumps, standard plumbing fittings, and common water glycol coolant. Dry coolers, heat exchangers, and chillers size to the facility's total thermal load. The 7.2 kW per unit thermal output (24,570 BTU per hour) scales proportionally to fleet size. No specialized dielectric fluid at $5+ per liter. No custom tank fabrication. Standard industrial cooling equipment available from any data center supplier. Power infrastructure requires 380 to 480V three phase commercial or industrial service. At 415V three phase the M73S+ draws approximately 17 amps per phase in rated mode, or 24 amps per phase in overclock mode. Fits within standard 20 amp commercial breakers in rated mode. Overclock mode requires upgraded 32 amp breakers for reliable operation. The M73 series lineup covers three bins at different hashrate and efficiency grades. M73 base: 470 TH/s at 14.5 J/TH. M73S mid: 500 TH/s at 13.5 J/TH. M73S+ top: 540 to 600 TH/s at 12.5 J/TH. All three share the 4U chassis, 7,200W rated power envelope, and water cooling architecture. Mix bins in the same rack based on acquisition cost optimization. Bitcoin mining economics: MillionMiner's $0.08 per kWh onsite calculator shows $17.64 daily revenue, $13.82 electricity, $3.81 net profit per day. At $0.04 per kWh industrial rates: $6.91 daily electricity, netting $10 to $11 daily per unit. At upper bin output of 600 TH/s in overclock mode, daily revenue improves meaningfully at the cost of higher electricity draw. Run overclock calculations carefully against your specific electricity rate because the additional 2.8 kW draw must recover through proportional hashrate gains to justify the efficiency tradeoff. 483 x 663 x 86 mm at 29.5 kg. Ethernet 10/100M management through standard Whatsminer firmware with Foreman, Awesome Miner, Hive OS compatibility. 5 to 45 degrees Celsius operating range at 5 to 95 percent humidity. PSU ships included. 360 day MicroBT manufacturer warranty. Free DDP delivery worldwide from MillionMiner.

MicroBT Whatsminer M73S+ 540 TH/s: Rack Mount Hydro at M70 Leading

The M73S+ sits at the efficiency peak of MicroBT's M70 generation
alongside the M76S+ immersion variant. Both share the 12.5 J/TH leading efficiency rating
documented by Blockspace Media and Hashrate Index at the Bitcoin MENA 2025 launch. The
M73S+ achieves this efficiency through rack mount hydro cooling rather than immersion, which
changes the infrastructure story meaningfully.
MillionMiner rated spec: 540 TH/s at 7,200W and 13.33 J/TH. Manufacturer headline per launch
coverage: 540 to 600 TH/s binning range at 12.5 J/TH with overclock mode scaling to 10,000W
for higher output. Operators run rated mode for stable 24/7 operation or push into overclock
when electricity and cooling capacity support higher draw.
Hydro differs from immersion. The M73S+ does not submerge in fluid. Water flows through
internal channels in a sealed 4U chassis and carries heat to an external cooling loop. Units
mount in standard 19 inch server racks alongside other data center equipment. 10 M73S+ units
per 42U rack produce 5.4 PH/s at 72 kW. Water cooling uses off the shelf pumps, standard
plumbing, and water glycol coolant. Immersion requires specialized dielectric fluid at higher cost
and custom tank infrastructure. For data center operators experienced with liquid cooled
compute servers, the M73 series integrates into familiar infrastructure.
483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase. Ships with 360 day MicroBT warranty
and free DDP worldwide.

هل تحتاج إلى مساعدة في الاختيار؟

يمكن لخبرائنا في التعدين مساعدتك في العثور على الأجهزة المثالية لمعدنك الخاص وميزانيتك.

Whatsminer M73S+ 540 TH/s Hydro 4U Bitcoin Miner

Top bin of MicroBT's rack mount hydro tier and efficiency co leader across
the entire M70 generation at 12.5 J/TH headline rating (tied with M76S+). MillionMiner rated
spec: 540 TH/s at 7,200W and 13.33 J/TH. Manufacturer headline: 540 to 600 TH/s binning
range with overclock mode reaching 10,000W. Closed loop water cooling in a 4U rack mount
chassis for standard 19 inch server racks. Avoids the specialized dielectric fluid and custom tank
infrastructure of immersion approaches. 10 units per 42U rack produce 5.4 PH/s at 72 kW.
Water cooling uses off the shelf pumps, standard plumbing, and common water glycol coolant.
483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase. Ships from MillionMiner with 360 day
warranty and free DDP worldwide.

540 TH/ث عند كفاءة رائدة M70

12.5 J/TH manufacturer headline per Blockspace and Hashrate Index. Ties the M76S+ for best efficiency across the entire M70 generation.

Standard 4U Rack Mount, Water Cooled

صندوق مغلق 4U لرفوف الخوادم ذات قياس 19 إنش. خطوط المياه، وليس خزانات الغمر. يتكامل مع البنية التحتية لمركز البيانات المبرّد بالسائل القائمة.

Rated 7,200W, Overclock to 10,000W

Rated mode at 540 TH/s and 7,200W. Overclock mode scales to 10,000W for approximately 600 TH/s peak hashrate at higher power draw.

Request a Bitcoin Miner Hosting Quote

4.7
نجمة نجمة نجمة نجمة نجمة

4.7/5 Verified on Trustpilot

  • ظرف 30,000+ miners hosted since 2020
  • مؤقت Trusted by 1,200+ customers globally
آيزو صُنع في ألمانيا تراستبيول
تقييم جوجل

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

عمال المناجم

عامل منجم

استضافة

استضافة

الأسئلة الشائعة

الأسئلة الشائعة

The M73S+ produces 540 TH/s of SHA-256 hashrate at 7,200W and 13.33 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Blockspace Media and Hashrate Index document the broader binning range at 540 to 600 TH/s with 12.5 J/TH leading efficiency rating. Overclock mode scales to 10,000W for approximately 600 TH/s peak output. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. The 12.5 J/TH rating ties the M73S+ with the M76S+ immersion variant as the efficiency leaders across the entire M70 generation.

Hydro cooling uses closed loop water circulation through internal channels in a sealed 4U chassis. The M73S+ does not submerge in fluid. Water absorbs heat inside the chassis and carries it to an external cooling loop through standard plumbing. Units install in 19 inch server racks alongside other data center equipment. Immersion cooling submerges the entire miner in dielectric fluid held in specialized tanks. The M73S+ hydro approach uses off the shelf pumps, standard plumbing, and common water glycol coolant. Immersion requires specialized dielectric fluid at higher cost per liter, custom tank infrastructure, and more complex fluid quality management.

Infrastructure familiarity and integration. Facilities already operating liquid cooled compute servers (data centers, colocation facilities, enterprise IT environments) have water cooling expertise and equipment. Adding M73S+ units extends existing infrastructure rather than building dedicated immersion tank systems. Standard 19 inch server racks and water lines fit into existing facility architecture. Immersion makes more sense for dedicated mining facilities purpose built around tanks, or operations where the density advantage of 19 M76S+ units per 100 kW panel outweighs the custom infrastructure cost.

Three bins across the M73 rack mount hydro tier. M73 base: 470 TH/s at 14.5 J/TH. M73S mid: 500 TH/s at 13.5 J/TH. M73S+ top (this product): 540 to 600 TH/s at 12.5 J/TH. All three share the identical 4U chassis, 7,200W rated power envelope, 380 to 480V three phase requirements, and water cooling architecture. Chip binning grade differentiates them. The M73S+ delivers 15 percent more hashrate than the base M73 at 14 percent better efficiency, at the acquisition price premium that top bin silicon commands.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 17 amps per phase in rated 7,200W mode, or 24 amps per phase in overclock 10,000W mode. At 480V three phase: approximately 15 amps in rated mode, 21 amps in overclock mode. Rated mode fits standard 20 amp commercial breakers. Overclock mode requires 32 amp breakers for reliable operation. Not suitable for standard residential or small commercial electrical systems. European, Middle Eastern, and industrial Asian facilities at 380 to 415V three phase have direct deployment paths.

Closed loop water circulation with off the shelf components. Required: circulation pumps sized for total fleet flow rate, standard plumbing fittings (no specialized immersion connectors), water glycol coolant mixture, external heat rejection through dry coolers or water to water heat exchangers, and inline filtration. Coolant volume scales roughly 2 to 4 liters per unit plus system reservoir capacity. Each M73S+ adds approximately 24,570 BTU per hour of thermal load. For rack scale deployment with multiple units, thermal rejection scales proportionally and uses standard data center cooling equipment available from any industrial supplier.

A standard 42U rack holds 10 M73S+ units (factoring space for cooling manifolds and cable management) producing 5.4 PH/s at 72 kW per rack. Compare against the M76S+ immersion option (19 units in tanks per 100 kW producing 7,410 TH/s) or M79S hydro 3U option (7 units per 100 kW producing 6,510 TH/s). The M73S+ rack mount approach wins on infrastructure familiarity and standard server rack integration. Immersion wins on aggregate hashrate per kilowatt of electrical capacity.

At MillionMiner's $0.08 per kWh onsite calculator: $17.64 daily revenue, $13.82 electricity, $3.81 net profit per day. At $0.07 per kWh industrial rates: approximately $12.10 daily electricity against similar revenue, netting $5 to $6 daily. At $0.04 per kWh negotiated industrial rates: $6.91 daily electricity, netting $10 to $11 daily profit per unit. At upper bin 600 TH/s output, daily revenue improves 11 percent over the 540 TH/s floor. Run overclock mode calculations against your electricity rate because the 2.8 kW additional draw must recover through proportional revenue gains.

أي عملة مشفرة تعتمد على إثبات العمل باستخدام SHA-256. البيتكوين (BTC) هي الهدف الأساسي. العملات المتوافقة الأخرى تشمل بيتكوين كاش (BCH)، بيتكوين ساوى (BSV)، فركتال بيتكوين (FB)، وDigiByte (DGB ستراك SHA-256). التعدين المشترك لـ BTC جنبًا إلى جنب مع BCH و BSV من خلال تجمعات دعم مثل ViaBTC وF2Pool يضيف إيرادات ثانوية هامشية.

نشر صناعي مع بنية تحتية للطاقة ثلاثية الطور وتبريد مائي. الخطوة الأولى: تثبيت خدمة كهربائية ثلاثية الطور من 380 إلى 480 فولت. الخطوة الثانية: تركيب وتشغيل دائرة التبريد المائي بما في ذلك المضخات، والسباكة، والمبردات الجافة، والملء الأول للسائل المبرد. الخطوة الثالثة: تثبيت وحدات M73S+ في حوامل قياس 19 إنش القياسية وربط وصلات مدخل/مخرج الماء بنظام المنفذ الخاص بك. التحقق من عدم وجود تسريبات قبل التشغيل. الخطوة الرابعة: توصيل مزود الطاقة PSU وإدارة Ethernet. الخطوة الخامسة: تشغيل الجهاز، السماح بتثبيت تدفق المبرد، العثور على عنوان IP الخاص بكل معدن من خلال DHCP، تكوين عنوان URL للمجمع ومحفظة البيتكوين عبر واجهة الويب الخاصة بـ Whatsminer، والتحقق من أن معدل التجزئة يصل إلى 524+ TH/s خلال 15 إلى 20 دقيقة لكل وحدة.

Yes, with appropriate infrastructure provisioning. Overclock mode scales the M73S+ to 10,000W and approximately 600 TH/s output. Requirements for stable overclock operation: electrical circuits sized for 32 amp per phase draw rather than 20 amp, water cooling loop with additional thermal margin (25 to 30 percent above rated mode capacity), and electricity pricing that makes the additional draw economically worthwhile. The 2.8 kW additional power in overclock mode must generate proportional hashrate gains to justify the electricity cost. At $0.04 per kWh industrial rates, overclock typically wins daily margin. At $0.08 per kWh or above, rated mode often delivers better net profit.

Water cooling maintenance. Weekly visual inspection of all fittings for leaks or corrosion. Monthly coolant quality testing (pH within spec, particulate levels minimal). Every 12 to 24 months full coolant replacement depending on fluid chemistry. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Hashboard failure rates on hydro units run lower than air cooled because chips operate at consistent temperatures. Water cooling maintenance is simpler than immersion fluid management because water glycol is cheaper and more widely available than dielectric fluid.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts. For fleet deployments above 5 PH/s (equivalent to 10+ M73S+ units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

Different deployment scales. M73S+: 540 to 600 TH/s at 7,200 to 10,000W and 12.5 J/TH headline in 4U chassis. Antminer S23 Hyd 3U: 1,160 TH/s at 11,020W and 9.5 J/TH in 3U chassis. Bitmain's S23 Hyd 3U leads on absolute hashrate per unit and efficiency per terahash. The M73S+ fits facilities wanting hydro mining at mid power tier with broader bin flexibility. For operations building dedicated petahash class deployment, the S23 Hyd 3U is the more aggressive choice. For operations integrating hydro mining into existing data center infrastructure at comfortable per unit scale, the M73S+ fits better.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document coolant testing schedule and maintenance logs to protect warranty coverage.

نعم. تدير شركة مليون miner مرافق استضافة مُدارة مزودة بنظام طاقة صناعية ثلاثي الطور وبنية تبريد بالمياه قادرة على دعم نشرات M73S+. يُلغي الاستضافة المُدارة نفقات رأس المال للبنية التحتية للمرفق. غالبًا ما تتفوق الاستضافة الاحترافية بأسعار صناعية تم التفاوض عليها على الاستضافة الذاتية عند احتساب جميع تكاليف البنية التحتية. تواصل مع فريق مبيعات مليون miner من خلال زر "احصل على عرض سعر" لمعرفة أسعار الاستضافة، وتوافر القدرات، والجداول الزمنية للنشر.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M73S+ units automatically through network scanning. Additional monitoring metrics for hydro operation (coolant flow rate, inlet/outlet temperatures) appear in hydro specific dashboards. Mixed brand and cooling type fleets handle through unified dashboards.

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack depending on capacity), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 7.2 kW rated: electricity at $5,045 at $0.08 per kWh, $2,522 at $0.04 per kWh industrial rates, water glycol coolant maintenance ($100 to $300 per unit annually), spare parts and maintenance. Water cooling infrastructure CapEx runs meaningfully lower than immersion tank systems, which is the primary economic argument for rack mount hydro over immersion deployment.

No. The M73S+ requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V 20A circuits. For high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling. The M73S+ is strictly industrial hardware for professional mining facilities and data centers.

Within the M73 rack mount hydro tier: the Whatsminer M73S at 500 TH/s and M73 at 470 TH/s provide lower bin alternatives in the same chassis. Cross cooling at MicroBT: immersion variants M76 and M78 series cover alternative liquid cooling for facilities with tank infrastructure, M79 and M79S cover high power hydro tier (14 kW and 20 kW per unit). Cross brand hydro: the Bitmain Antminer S23 Hyd 3U at 1.16 PH/s provides vendor diversification at higher power tier. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining. MillionMiner's ASIC hosting service accepts M73S+ units at negotiated industrial electricity rates.