Skladem

Bitmain

Bitmain Antminer L11 Hyd 2U (35GH)

Model: Antminer L11 Hyd 2U

Nový

35 GH/s hydro cooled Scrypt miner in a 2U rack mount chassis for Litecoin (LTC) and Dogecoin (DOGE) merged mining. Bitmain's highest density Scrypt product, packing 21 units per 42U rack to produce 735 GH/s aggregate hashrate, over three times the per rack output of the 3U L11 HU6 variant. 5,775W at 0.165 J/MH efficiency. Water cooling reduces noise to 50 dB, a 25 dB reduction from air cooled Scrypt miners that matters significantly in multi tenant data centers or facilities where staff work near hardware. 380 to 480V three phase industrial power. Shares 2U format with the older L9 Hyd 2U, allowing mixed rack deployment on shared water manifolds for facilities upgrading gradually. Released December 2025. Mines Scrypt coins including LTC, DOGE, BEL, PEP, DGB. 445 x 88 x 670 mm at 20.5 kg. Ships with PSU, Bitmain factory warranty, and free DDP worldwide from MillionMiner. Price: $10,989.

35 GH/s 5775W Scrypt 165 J/TH

Vyberte dostupnost

Množství

Celková cena

$10,989.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bankovní převod | BTC | ETH | USDT

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

35 GH/s

Výkon

5775 W

Účinnost

165.00 J/GH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$19.05 $133.35 $571.50
Elektrická energie
-$11.09 -$77.63 -$332.70
Zisk
$7.96 $55.72 $238.80

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 09, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 35 GH/s
Spotřeba energie 5775 W
Účinnost 165.00 J/GH
Algoritmus Scrypt
Model Antminer L11 Hyd 2U
Rok vydání Prosince 2025
Hladina hluku 50 dB
Rozměry 445 x 88 x 670mm
Váha 20 g
Napětí 380 - 480v
Rozhraní Ethernet
Provozní teplota 5 - 45 °C
vlhkost 5 - 95 %
Typ chlazení Hydro
Formát stojanu 2U

Co je v krabici

Antminer L11 Hyd 2U
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Detaily produktu

Bitmain Antminer L11 Hyd 2U 35 GH/s Hydro Cooled Rack Mount Scrypt Miner for Litecoin and Dogecoin: Specifications, Density Economics, and Deployment Guide

The Bitmain Antminer L11 Hyd 2U is the density leader of Scrypt mining hardware. 35 GH/s of Scrypt hashrate at 5,775W in a 2U rack mount chassis with closed loop water cooling packs more Scrypt hashrate per rack unit than any alternative on the market in early 2026. Released December 2025, this represents Bitmain's latest generation Scrypt silicon at 0.165 J/MH efficiency (equivalently 165 J/GH). Rack density math: a standard 42U rack holds 21 L11 Hyd 2U units, producing 735 GH/s aggregate Scrypt hashrate at approximately 121 kW per rack. Compare against the larger 3U L11 HU6 variant: only 7 units fit per 42U rack, producing 231 GH/s aggregate. The 2U hydro variant delivers more than three times the Scrypt hashrate per rack of floor space. For facilities where physical floor space is the binding constraint rather than electrical capacity, this density advantage is decisive. The trade off is operational complexity. 21 units per rack means three times more water quick disconnect fittings to inspect and maintain, three times more power cords to manage, three times more individual chassis to monitor, and three times more firmware update cycles to coordinate. For operations optimizing purely for per unit maintenance simplicity, the 3U L11 HU6 with fewer units per rack presents a different optimization target. Water cooling enables two distinct advantages beyond just thermal management. First: the 2U form factor would be thermally impossible with air cooling at 5,775W per unit continuous draw. Air cooling requires more surface area and airflow path than a 2U chassis can provide at this power density. Hydro cooling makes the density class physically possible. Second: noise drops to 50 dB, compared to 75 dB typical for air cooled Scrypt miners like the L11 Pro or L9 series. The 25 dB gap represents roughly half the perceived sound intensity and opens deployment options unavailable to air cooled hardware. Multi tenant colocation facilities, data centers with mixed workloads, research facilities, and operations where staff work near hardware regularly all benefit meaningfully from the noise reduction. Water cooling infrastructure requirements: closed loop water circulation using off the shelf pumps, standard plumbing fittings, and common water glycol coolant. Dry coolers, heat exchangers, and chillers size to the facility's total thermal load. The 5,775W per unit thermal output (approximately 19,715 BTU per hour per unit) scales proportionally. A fully loaded 42U rack producing 121 kW thermal output requires approximately 413,300 BTU per hour heat rejection capacity. The L11 Hyd 2U shares its 2U form factor exactly with the previous generation L9 Hyd 2U (27 GH/s Scrypt). This allows mixed rack deployment on shared water manifolds for facilities upgrading gradually from L9 to L11 generation hardware. Existing L9 installations can introduce L11 units incrementally without tearing out the water cooling infrastructure, replacing individual units as capital becomes available or as L9 warranty periods expire. Scrypt merged mining protocol is a key economic feature. One fleet simultaneously mines multiple Scrypt compatible cryptocurrencies through supporting pools without splitting hashrate across algorithms. Primary targets: Litecoin (LTC) with the largest Scrypt network, Dogecoin (DOGE) with strong retail interest and merged mining support. Secondary targets included in the mining reward stream: Bellscoin (BEL), PepeCoin (PEP), DigiByte Scrypt chain (DGB), Luckycoin (LKY), Catcoin (CAT), DingoCoin (DINGO), Auroracoin (AUR), and smaller Scrypt chains. Major pools supporting merged mining include F2Pool (26.7 percent Scrypt network share), ViaBTC (29.0 percent), AntPool (17.8 percent), EMCD (6.3 percent). Profitability economics depend heavily on electricity rate. ASIC Miner Value data at AED 0.53 per kWh (approximately $0.144 per kWh residential rates) shows negative daily margins reflecting current Scrypt market conditions. MillionMiner's $0.08 per kWh onsite calculator shows $22.79 daily revenue, $11.09 electricity, $11.70 net daily profit per unit. At $0.04 per kWh negotiated industrial rates: $5.54 daily electricity, netting $17 daily profit per unit. Economic viability requires industrial electricity below $0.10 per kWh for reliably positive returns. ROI timelines vary significantly based on LTC and DOGE price trajectory. Model conservatively against current network difficulty rather than assuming favorable coin price movements. 380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 13.5 amps per phase continuous draw. At 480V three phase: approximately 11.7 amps per phase. Fits within standard 20 amp commercial breakers. Bitmain APW series hydro PSU included. 445 x 88 x 670 mm at 20.5 kg per unit. Weight planning matters for fully loaded racks: 21 units totals approximately 430 kg plus water and infrastructure weight. Verify rack weight capacity and facility floor loading before deployment. 5 to 45 degrees Celsius operating range at 5 to 95 percent humidity. Ethernet 10/100M management through Antminer firmware. Price at MillionMiner: $10,989. Ships with PSU, Bitmain factory warranty, and free DDP delivery worldwide.

Bitmain Antminer L11 Hyd 2U 35 GH/s: The Density Leader in Scrypt Mining

The L11 Hyd 2U redefines Scrypt mining density. 35 GH/s of Scrypt
hashrate in a 2U rack mount chassis allows 21 units per 42U rack, producing 735 GH/s
aggregate. Compare against the larger 3U L11 HU6 which fits only 7 units per 42U rack at 231
GH/s aggregate. The 2U variant delivers more than three times the Scrypt hashrate per rack of
floor space. The trade off is three times more water connections, power connections, and
individual units to manage per rack.
Water cooling enables two specific advantages. First: the 2U form factor would be thermally
impossible with air cooling at 5,775W per unit, so density at this level requires hydro. Second:
noise drops to 50 dB, compared to 75 dB typical for air cooled Scrypt hardware. The 25 dB gap
represents roughly half the perceived sound intensity, which matters in multi tenant colocation
facilities, data centers with mixed workloads, and operations where staff work near mining
hardware regularly.
Released December 2025, the L11 Hyd 2U is the latest generation Bitmain Scrypt silicon at
0.165 J/MH efficiency (165 J/GH). Scrypt merged mining protocol means one fleet
simultaneously mines Litecoin (LTC), Dogecoin (DOGE), and other Scrypt compatible coins
through supporting pools without splitting hashrate across algorithms. Current ASIC Miner Value
profitability data at AED 0.53 per kWh (approximately $0.144 per kWh) shows negative daily
margins, reflecting Scrypt market conditions in early 2026 at consumer residential electricity
rates. At MillionMiner's $0.08 per kWh onsite calculator: $22.79 daily revenue, $11.09 electricity,
$11.70 net daily profit. Economic viability requires industrial electricity below $0.10 per kWh for
positive returns.
380 to 480V three phase. 445 x 88 x 670 mm at 20.5 kg. Price at MillionMiner: $10,989.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Antminer L11 Hyd 2U 35 GH/s Scrypt Miner LTC DOGE

Nejvyšší hustota Scrypt těžaře od Bitmainu. 35 GH/s v 2U skřínce na rack, pojme 21 jednotek na 42U racku, což produkuje celkový výkon 735 GH/s, více než třikrát větší než výkon na rack u varianty 3U L11 HU6 (231 GH/s na rack). Vodou chlazený při 50 dB, což je o 25 dB méně než vzduchem chlazené Scrypt zařízení, což je důležité v multi-tenant datových centrech. 5775 W při efektivitě 0,165 J/MH (165 J/GH) na třífázové napětí 380 až 480 V. Těží Scrypt mince prostřednictvím protokolu spojovaného těžení: Litecoin (LTC) a Dogecoin (DOGE) současně na jednom plavidle, s podporou Bellscoin, PepeCoin, DigiByte Scrypt řetězce a dalších Scrypt mincí. Stejný formát 2U jako L9 Hyd 2U, vhodný pro smíšené nasazení v racku při postupném vylepšování plavidla. Rozměry 445 x 88 x 670 mm, váha 20,5 kg. Provozní rozsah 5 až 45 stupňů Celsia.

35 GH/s Scrypt Density Leader

21 units per 42U rack produce 735 GH/s aggregate, over three times the per rack output of the 3U L11 HU6 variant. Highest Scrypt density available.

50 dB Hydro Noise Výhoda

25 dB quieter than air cooled Scrypt miners. Opens deployment in multi tenant data centers and facilities where staff work near hardware.

Sloučené těžení LTC a DOGE

Scrypt protocol mines Litecoin and Dogecoin simultaneously on one fleet plus BEL, PEP, DGB, and other Scrypt chains through supporting pools.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

The L11 Hyd 2U produces 35 GH/s of Scrypt hashrate at 5,775W continuous power draw and 0.165 J/MH efficiency (equivalently 165 J/GH). Released December 2025 as Bitmain's latest generation hydro cooled Scrypt silicon in the compact 2U form factor. The 35 GH/s figure represents the highest Scrypt hashrate per rack unit currently available from any manufacturer, making the L11 Hyd 2U the density leader for Scrypt mining in early 2026.

Same generation silicon, different chassis form factor. L11 Hyd 2U: 35 GH/s per unit at 5,775W in 2U. L11 HU6 (3U): similar per unit performance but in 3U rack mount. Critical difference is rack density. A 42U rack holds 21 L11 Hyd 2U units producing 735 GH/s aggregate, versus 7 L11 HU6 units producing roughly 231 GH/s aggregate. The 2U variant delivers more than three times the Scrypt hashrate per rack of floor space. Trade off: three times more water connections, power cords, and individual units to maintain per rack. Optimize for density with 2U, or for per unit simplicity with 3U.

Two scenarios favor high density hardware. First: facilities with limited physical floor space where every square meter of real estate carries meaningful cost, common in urban colocation facilities or data centers operating under space constraints. Second: facilities scaling Scrypt operations within existing electrical capacity ceilings where adding more racks means repurposing existing space rather than building new facility. The L11 Hyd 2U extracts maximum Scrypt hashrate from available floor space. For operations with unlimited floor space and unlimited electrical capacity, density advantages matter less.

All Scrypt proof of work cryptocurrencies. Primary targets through merged mining: Litecoin (LTC) with the largest Scrypt network, and Dogecoin (DOGE) with strong retail interest. Merged mining means one fleet simultaneously contributes hashrate to both networks without splitting output. Secondary Scrypt coins supported through major pools: Bellscoin (BEL), PepeCoin (PEP), DigiByte Scrypt chain (DGB), Luckycoin (LKY), Catcoin (CAT), DingoCoin (DINGO), Auroracoin (AUR), GoldCoin (GLC), Junkcoin (JKC), and smaller forks. Revenue from all simultaneously mined chains streams into the same wallet addresses. Quai (QUAI) at 722 QUAI daily per current ASIC Miner Value data represents emerging Scrypt compatible chain activity.

Sloučené těžení umožňuje, aby stejná hashingová práce kvalifikovala pro odměny za bloky na více kompatibilních sítích současně. U Scrypt to znamená, že jedna skupina odesílající hash hodnoty do sloučeného těžebního poolu získává LTC, DOGE, BEL a další Scrypt odměny bez rozdělení výpočetního úsilí. Ekonomický efekt: odměny Dogecoin jsou v podstatě volným dodatečným příjmem navíc k těžbě Litecoin, protože stejná práce kvalifikuje pro obě měny. Většina provozovatelů používajících hardware Scrypt považuje odměny DOGE za bonusový výnos nad primární těžbou LTC. Konfigurace poolu automaticky zajišťuje protokol sloučeného těžení prostřednictvím podporovaných poolů jako jsou F2Pool, ViaBTC, AntPool a EMCD.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 13.5 amps per phase continuous draw at 5,775W. At 480V three phase: approximately 11.7 amps per phase. Fits within standard 20 amp commercial breakers with headroom. Not suitable for standard residential or small commercial electrical systems. European, Middle Eastern, and industrial Asian facilities at 380 to 415V three phase have direct deployment paths. North American industrial facilities at 480V three phase also deploy directly.

Closed loop water circulation with standard industrial components. Required: circulation pumps sized for total fleet flow rate, standard plumbing fittings, water glycol coolant mixture, external heat rejection through dry coolers or water to water heat exchangers, and inline filtration. Coolant volume scales roughly 2 to 4 liters per unit plus system reservoir capacity. Each L11 Hyd 2U adds approximately 19,715 BTU per hour of thermal load. A fully loaded 42U rack producing 121 kW thermal output requires roughly 413,300 BTU per hour heat rejection capacity. Uses standard data center cooling equipment from any industrial supplier.

Yes. The 2U form factor is identical between generations, with same water connector geometry, same chassis dimensions, same rack mounting hardware, and same water manifold compatibility. Mixed rack deployment allows facilities to upgrade gradually from L9 (27 GH/s) to L11 (35 GH/s) generation hardware as capital becomes available or as L9 warranty periods expire. No infrastructure changes required when introducing L11 units into existing L9 hydro installations. Fleet management through standard Antminer firmware handles mixed generation deployment transparently.

Highly electricity rate dependent. MillionMiner's $0.08 per kWh onsite calculator shows $22.79 daily revenue, $11.09 electricity, $11.70 net daily profit per unit. ASIC Miner Value data at AED 0.53 per kWh (approximately $0.144 per kWh residential rates) shows negative daily margins reflecting current Scrypt market conditions at consumer electricity pricing. At $0.04 per kWh negotiated industrial rates: $5.54 daily electricity, netting roughly $17 daily profit per unit. At $0.07 per kWh typical industrial rates: $9.71 daily electricity, netting roughly $13 daily. Economic viability requires industrial electricity below $0.10 per kWh for reliably positive returns. Scrypt profitability varies significantly with LTC and DOGE price movements.

50 dB for the L11 Hyd 2U versus 75 dB typical for air cooled Scrypt miners. The 25 dB gap represents roughly half the perceived sound intensity to human ears. Practical implications: multi tenant colocation facilities can deploy L11 Hyd 2U hardware without disrupting neighboring tenant operations, data centers with mixed workloads avoid acoustic interference with staff areas, research facilities and test environments can operate mining hardware alongside sensitive equipment, and operations where staff work near hardware for extended periods reduce occupational noise exposure significantly.

Not practically. Despite the quieter 50 dB acoustic profile, the L11 Hyd 2U requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure with pumps and heat rejection capacity, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V single phase circuits. For residential Scrypt mining, air cooled models like smaller Antminer L series units or the L9 are more appropriate product matches. The L11 Hyd 2U is strictly industrial hardware for professional mining facilities.

Industrial deployment with three phase power and water cooling infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission water cooling loop including pumps, plumbing, dry coolers, and initial coolant fill. Step three: rack mount L11 Hyd 2U units in standard 19 inch racks and connect water inlet/outlet fittings to your manifold system. Verify zero leaks before energizing. Step four: connect PSU power and Ethernet management. Step five: power on, allow coolant flow to stabilize, find each miner IP through DHCP, configure Scrypt merged mining pool URL and LTC/DOGE wallet addresses through Antminer web interface, verify hashrate reaches 34 to 35 GH/s within 10 to 15 minutes per unit.

Hlavní těžební bazény pro sloučené Scrypt zahrnují F2Pool (26,7 procenta podíl na Scrypt síti), ViaBTC (29,0 procenta s podporou sloučené těžby), AntPool (17,8 procenta) a EMCD (6,3 procenta). Všechny podporují současné těžení LTC a DOGE plus odměny za sekundární Scrypt řetězec. Porovnání poplatků za bazén: F2Pool PPLNS se 4 procenty nebo PPS se 4 procenty, ViaBTC PPLNS s 2 procenty, AntPool PPS s 3 procenty, EMCD PPLNS s 1,5 procenta (s 10procentní slevou přes kód AMV10 při označení ASIC Miner Value). U nasazení flotily nad 1 PH/s Scrypt (equivalent k více než 28 jednotkám L11 Hyd 2U) mohou být k dispozici dohodnuté poplatky za bazén nižší než standardní sazby.

Water cooling maintenance. Weekly visual inspection of all fittings for leaks or corrosion. Monthly coolant quality testing (pH within spec, particulate levels minimal). Every 12 to 24 months full coolant replacement depending on fluid chemistry. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Higher unit count per rack (21 units versus 7 in the 3U variant) increases cumulative maintenance cycles per rack but individual unit failures have smaller fleet impact. Budget 3 to 5 percent of acquisition cost annually per unit for coolant, filtration, and spare parts.

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 5.775 kW: electricity at $4,047 at $0.08 per kWh, $3,540 at $0.07 per kWh industrial rates, or $2,023 at $0.04 per kWh negotiated industrial rates. Coolant maintenance: $100 to $300 per unit annually. Spare parts: $200 to $400 annually per unit. 3 year TCO per unit at $0.07 per kWh: approximately $13,000 hardware and infrastructure plus $10,620 electricity.

Yes. MillionMiner operates managed hosting facilities with three phase industrial power and water cooling infrastructure capable of supporting L11 Hyd 2U deployments. Hosted deployment eliminates facility infrastructure CapEx. Professional hosting at negotiated industrial rates often beats self hosting for Scrypt miners without access to industrial electricity below $0.08 per kWh, because Scrypt profitability margins are tight at standard commercial rates. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

Bitmain's factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document coolant testing schedule and maintenance logs to protect warranty coverage. MillionMiner routes claims through direct Bitmain channels for faster resolution than secondary market purchases provide.

Standard Antminer firmware provides the same web interface, pool configuration format, and management API as other Bitmain miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover L11 Hyd 2U units automatically through network scanning. Additional monitoring metrics for hydro operation (coolant flow rate, inlet/outlet temperatures) appear in hydro specific dashboards. Mixed brand and cooling type fleets handle through unified dashboards, with Scrypt specific metrics tracked alongside SHA-256 or Equihash operations if running multi algorithm mining facilities.

Depends on electricity rate and LTC/DOGE price outlook. Current economics per MillionMiner onsite calculator show $11.70 net daily profit at $0.08 per kWh, so industrial facilities with rates below $0.10 per kWh maintain healthy margins. ASIC Miner Value data at consumer residential rates shows negative margins, indicating Scrypt mining at residential electricity is not economically viable at current LTC/DOGE prices. Dogecoin retail interest and Litecoin network effects continue to support Scrypt mining economics but margins have compressed over multiple years as network difficulty has grown faster than coin prices. Model conservatively against current network conditions rather than assuming favorable future price movements.

Within Scrypt: the previous generation L9 Hyd 2U at 27 GH/s (same 2U chassis, compatible with shared water manifolds), air cooled L11 Pro for facilities without hydro infrastructure, and older L7 series hardware at budget tier pricing. Cross algorithm diversification options: Antminer S21 XP at 270 TH/s or Whatsminer M70S+ at 244 TH/s for SHA-256 Bitcoin mining, Antminer KS7 at 45 TH/s for KHeavyHash Kaspa mining, Antminer Z15 at 420 kSol/s for Equihash Zcash mining, Goldshell HS5 series for Handshake (HNS) mining. For multi algorithm fleet diversification, the L11 Hyd 2U represents the Scrypt component of a balanced portfolio. MillionMiner's ASIC hosting service accepts L11 Hyd 2U units at negotiated industrial electricity rates.

Get a Quote