Skladem

Bitmain

Bitmain Antminer L9 Hyd 2U (27GH)

Model: Antminer L9 Hyd 2U

Nový

Bitmain's hydro cooled rack mount Scrypt ASIC miner (Bitmain SKU U2L9H) for Litecoin (LTC), Dogecoin (DOGE), and Bellscoin (BELLS) merged mining. 27 GH/s Scrypt at 5,670W and 0.21 J/MH efficiency in a 2U rack chassis. Previous generation to the L11 Hyd 2U (35 GH/s) at lower acquisition cost, same 2U format for mixed rack deployment during fleet transitions. 50 dB liquid to chip cooling versus 75 dB air cooled L9. 380 to 415V three phase industrial input. 445 x 88 x 670 mm chassis. Merged mining delivers LTC, DOGE, and BELLS simultaneously from 27 GH/s, typically 20 to 40 percent higher combined revenue than solo LTC. Ships with PSU, cables, 6 month Bitmain warranty, and free DDP worldwide from MillionMiner.

27 GH/s 5670W Scrypt 210 J/TH

Vyberte dostupnost

Množství

Celková cena

$6,900.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bankovní převod | BTC | ETH | USDT

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

27 GH/s

Výkon

5670 W

Účinnost

210.00 J/GH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$16.49 $115.43 $494.70
Elektrická energie
-$10.89 -$76.23 -$326.70
Zisk
$5.60 $39.20 $168.00

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 27 GH/s
Spotřeba energie 5670 W
Účinnost 210.00 J/GH
Algoritmus Scrypt
Model Antminer L9 Hyd 2U
Rok vydání Nov 2025
Hladina hluku 50 dB
Rozměry 445 x 88 x 670mm
Váha 20 kg
Napětí 100-240V
Rozhraní Ethernet
Provozní teplota 5 - 45 °C
vlhkost 5-95%
Typ chlazení Hydro
Formát stojanu 2U

Co je v krabici

Antminer L9 Hyd 2U
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Detaily produktu

Bitmain Antminer L9 Hyd 2U 27 GH/s Hydro Cooled Rack Mount Scrypt ASIC Miner for Litecoin and Dogecoin Merged Mining

The Bitmain Antminer L9 Hyd 2U (Bitmain SKU U2L9H) is a hydro cooled rack mount Scrypt ASIC miner for Litecoin and Dogecoin merged mining. 27 GH/s Scrypt at 5,670W continuous draw and 0.21 J/MH (210 J/GH) efficiency. ±3 percent hashrate tolerance and ±5 percent power tolerance. 2U rack mount chassis at 445 x 88 x 670 mm. 380 to 415V three phase input with approximately 12A maximum current per phase and 50 to 60Hz frequency range. 50 dB liquid to chip cooling. 5 to 45 degrees Celsius operating range. Ethernet 10/100M management through standard Bitmain firmware. Scrypt generational context: L3+ at 504 MH/s, L7 at 9.5 GH/s, L9 at 17 GH/s air cooled, L9 Hyd 2U at 27 GH/s, L11 at 20 to 21 GH/s air cooled, L11 Hyd 2U at 35 GH/s, L11 HU6 at 33 GH/s. The L9 Hyd 2U sits as the hydro cooled variant of the L9 platform, delivering approximately 59 percent more hashrate than the air cooled L9 through hydro cooling's ability to sustain higher chip power density without thermal throttling. Efficiency remains at the L9 family 0.21 J/MH baseline, approximately 18 percent worse per megahash than the newer L11 family at 0.172 to 0.184 J/MH. Fleet transition value distinguishes the L9 Hyd 2U at current generation pricing. The 2U rack mount format matches the newer L11 Hyd 2U exactly, allowing mixed rack deployment during gradual L9 to L11 fleet transitions. Similar water cooling plumbing connections simplify infrastructure conversions. Operations can deploy L9 Hyd 2U units at lower capital cost for immediate hashrate expansion, then migrate selected slots to L11 Hyd 2U as budget cycles and fleet refresh permit. This transition flexibility is specific to rack mount hydro fleet operators and does not apply to operators choosing between air cooled and hydro deployment tiers. Rack density analysis. 21 L9 Hyd 2U units fit per standard 42U rack, producing 567 GH/s total Scrypt hashrate at approximately 119 kW continuous power per rack. The newer L11 Hyd 2U at 35 GH/s per unit produces 735 GH/s per rack at similar power density. The L9 Hyd 2U delivers 23 percent less per rack hashrate than the L11 Hyd 2U at lower acquisition cost per unit. For facilities planning staged deployment or operators preferring deeper amortization on mature hardware, the L9 Hyd 2U delivers the rack mount hydro entry tier. Scrypt merged mining produces Litecoin, Dogecoin, and Bellscoin simultaneously from the same 27 GH/s hashrate through configured merged mining pools. Combined revenue typically runs 20 to 40 percent above solo LTC at the same hashrate. Luckycoin, Junkcoin, and Pepecoin also merge mine at varying pool support. Three to six coin simultaneous output from one device is a structural Scrypt advantage that SHA-256 Bitcoin mining and most other algorithms cannot match. Acoustic characteristics: 50 dB liquid to chip cooling versus 75 dB on air cooled L9 units, roughly 75 percent less perceived loudness. In shared data center environments or facilities with on site staff, the 50 dB level means staff can work around deployed hardware without hearing protection. Air cooled 75 dB deployment typically requires hearing protection for extended exposure and creates tenant complaints in multi tenant facilities. Hydro infrastructure requirements. Unlike the L11 HU6 with integrated all in one cooling, the L9 Hyd 2U requires external facility hydro infrastructure: coolant distribution unit (CDU), dry cooler or chiller, heat exchanger, pumps, and plumbing connecting miner cold plates to facility cooling loops. Deployment requires existing hydro infrastructure or facility CapEx to build it. For facilities without existing hydro capacity, the integrated L11 HU6 or air cooled L11 Pro represent alternatives that avoid the facility infrastructure requirement. Power infrastructure. 380 to 415V three phase industrial input at approximately 12A maximum current per phase. Not available in residential or most light commercial settings. Purpose built for professional mining facilities with three phase power distribution, water cooling loops, and 2U rack infrastructure. Ships with PSU, power cables, quick start guide, 6 month Bitmain factory warranty, and free DDP worldwide delivery from MillionMiner.

Antminer L9 Hyd 2U 27 GH/s: Hydrochlazený rackový těžič scrypt od Bitmainu

The Antminer L9 Hyd 2U (Bitmain SKU U2L9H) is Bitmain's hydro cooled
rack mount Scrypt ASIC miner. 27 GH/s Scrypt at 5,670W and 0.21 J/MH efficiency in a 2U rack
chassis. The previous generation to the L11 Hyd 2U (35 GH/s), offering lower acquisition cost at
reduced performance per unit.
Fleet transition value sets the L9 Hyd 2U apart. The 2U rack mount format matches the newer
L11 Hyd 2U, allowing mixed rack deployment during gradual L9 to L11 fleet transitions. Similar
water cooling connections simplify plumbing conversions. Operations can deploy L9 Hyd 2U
units today at lower capital cost, then migrate selected slots to L11 Hyd 2U as budget and fleet
refresh cycles permit.
21 units per 42U standard rack at 567 GH/s total per rack. L11 Hyd 2U produces 735 GH/s per
rack at 23 percent higher density. The L9 Hyd 2U delivers the lower capital entry point into rack
mount hydro Scrypt deployment.
Scrypt merged mining delivers LTC, DOGE, and BELLS simultaneously from 27 GH/s, typically
20 to 40 percent higher combined revenue than solo LTC. 50 dB liquid to chip cooling versus 75
dB air cooled L9. 380 to 415V three phase industrial input with approximately 12A maximum
current per phase. 445 x 88 x 670 mm chassis.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Bitmain Antminer L9 Hyd 2U 27 GH/s Hydro Scrypt LTC DOGE Rack Miner

Hydro chladicí rackový Scrypt ASIC od Bitmainu (SKU Bitmain U2L9H). 27 GH/s při příkonu 5 670 W a efektivitě 0,21 J/MH v rackovém skříňovém systému 2U. Předchozí generace k L11 Hyd 2U (35 GH/s) s nižší pořizovací cenou, stejný formát 2U pro smíšené nasazení v racku během přechodu fleetů L9 na L11. 21 jednotek v 42U racku s celkovým výkonem 567 GH/s. Chlazení kapalinou k čipu s hlučností 50 dB versus 75 dB u vzduchového chlazení L9. Třífázový průmyslový vstup 380 až 415 V. Skříň rozměrů 445 x 88 x 670 mm. Merged mining umožňuje současně těžit LTC, DOGE a BELLS, s celkovým výkonem 27 GH/s, což přináší obvykle o 20 až 40 procent vyšší kombinované příjmy než solo těžení LTC. Dodáváno s PSU, kabely, 6měsíční zárukou Bitmain a zdarma DDP po celém světě.

27 GH/s Hydro Cooled Rack Mount

59 percent more hashrate than the air cooled L9 through hydro cooling. 0.21 J/MH efficiency on 5,670W in a 2U rack chassis.

Fleet Transition Format Match

Same 2U rack mount format as the L11 Hyd 2U. Mixed rack deployment during L9 to L11 fleet transitions with similar plumbing connections.

50 dB Vodouchlazený tichý

Liquid to chip cooling drops noise to 50 dB versus 75 dB air cooled L9. Staff can work around deployed hardware without hearing protection.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

27 GH/s Scrypt at 5,670W continuous draw and 0.21 J/MH (210 J/GH) efficiency. Bitmain's ±3 percent tolerance produces real world output between 26.2 and 27.8 GH/s. 59 percent more hashrate than the air cooled L9 at 17 GH/s through hydro cooling's ability to sustain higher chip power density.

2U rack mount chassis at 445 x 88 x 670 mm per MillionMiner's specification. The 88 mm chassis height corresponds to 2U in standard 19 inch rack measurement. Fits standard server racks without custom mounting hardware. 21 units per 42U rack produces 567 GH/s total.

50 dB from the liquid to chip cooling design, roughly 75 percent less perceived loudness than the 75 dB air cooled L9. Staff can work around deployed hardware without hearing protection. Air cooled L9 deployment typically requires hearing protection for extended exposure.

External facility hydro infrastructure required. Unlike the L11 HU6 with integrated all in one cooling, the L9 Hyd 2U connects to external coolant distribution unit (CDU), dry cooler or chiller, heat exchanger, pumps, and plumbing. Deployment requires existing hydro capacity or facility CapEx to build it. For facilities without existing hydro infrastructure, the L11 HU6 (integrated cooling) or air cooled L11 Pro are alternatives.

380 to 415V three phase industrial input with approximately 12A maximum current per phase and 50 to 60Hz frequency range. Not available in residential or most light commercial settings. Purpose built for professional mining facilities with three phase power distribution.

All Scrypt algorithm cryptocurrencies through merged mining. Primary coins: Litecoin (LTC), Dogecoin (DOGE), Bellscoin (BELLS). Additional Scrypt coins: Luckycoin (LKY), Junkcoin (JKC), Pepecoin (PEP). Combined revenue typically runs 20 to 40 percent above solo LTC at the same hashrate.

21 units per 42U standard rack at 567 GH/s total Scrypt hashrate and approximately 119 kW continuous power per rack. Compared to the newer L11 Hyd 2U at 35 GH/s per unit (735 GH/s per rack, 23 percent higher density), the L9 Hyd 2U delivers the lower capital entry tier into rack mount hydro Scrypt deployment.

Yes. MillionMiner hosting services accept L9 Hyd 2U units at managed facilities with three phase power and existing hydro cooling infrastructure. The 380 to 415V input and 5,670W draw align with industrial hosting standards. Contact MillionMiner for hosting rate tiers and availability.

6 month Bitmain factory warranty on new units. Box contents: Antminer L9 Hyd 2U, PSU, power cables, and quick start guide. Ships from MillionMiner with free DDP worldwide delivery covering all customs clearance, import duties, and taxes.

L9 Hyd 2U při 27 GH/s, 5670W a 0,21 J/MH. L11 Hyd 2U při 35 GH/s, 5676W a 0,162 J/MH. L11 Hyd 2U nabízí o 30 procent více hashrate při téměř stejné spotřebě (o 23 procent lepší efektivita na megahash) ve stejném formátu 2U rámu. Stejné vodní chladicí připojení umožňuje smíšené nasazení racků během přechodů flotily z L9 na L11. L9 Hyd 2U vyměňuje hashrate a efektivitu za nižší pořizovací náklady na jednotku.

Air cooled L9 at 17 GH/s, 3,570W, and 0.21 J/MH. L9 Hyd 2U at 27 GH/s, 5,670W, and 0.21 J/MH. Same BM1485 chip architecture and same efficiency per megahash. Hydro cooling enables 59 percent more hashrate per unit through sustained higher chip power density without thermal throttling. Power draw increases proportionally to hashrate gain. The hydro variant trades air cooled deployment simplicity for rack mount density and 50 dB acoustic advantage.

L9 Hyd 2U při 27 GH/s, 5 670 W, 0,21 J/MH v 2U skříni vyžadující externí hydroelektrárnu. L11 HU6 při 33 GH/s, 5 676 W, 0,172 J/MH s integrovaným all-in-one chlazením eliminujícím infrastrukturu externí zařízení. L11 HU6 poskytuje o 22 procent vyšší hash rate při o 18 procent lepší účinnosti a odstraňuje bariéru kapitálových výdajů na hydroelektrárnu. L9 Hyd 2U nabízí výhodu hustoty 2U skříně (21 jednotek na 42U rack vs 7 jednotek) pro zařízení s již existující kapacitou hydro.

445 x 88 x 670 mm chassis at 20 kg per MillionMiner's specification. Alternative distributor documentation (Mining Now, CryptoMinerBros) lists 509 x 481 x 87 mm at 19.1 kg. The slight dimensional and weight discrepancy may reflect shipping packaging versus bare chassis. Verify with MillionMiner for logistics planning.

No. The 380 to 415V three phase input is not available in residential settings. 5,670W continuous draw requires industrial electrical service with three phase distribution. The 2U rack mount chassis requires 19 inch rack infrastructure. External hydro cooling loop requires facility infrastructure. For quiet home Scrypt mining, Fluminer L3 at 9.5 GH/s and 45 dB or Fluminer L1 Pro at 6 GH/s and 45 dB are appropriate options.

5 až 45 stupňů Celsia při vlhkosti 5 až 95 procent podle specifikace MillionMiner. Alternativní dokumentace distributora (CryptoMinerBros) uvádí 20 až 50 stupňů Celsia, což odráží potřebu hydrochlazení udržovat chladicí kapalinu nad bodem rosného bodu kondenzace. Pro nasazení v chladném klimatu s teplotami zařízení pod 20 stupňů Celsia ověřte specifikaci chladicí kapaliny s dokumentací Bitmain.

Four step setup. Verify 380 to 415V three phase service capable of 5,670W continuous. Connect PSU to miner. Connect water cooling inlet and outlet to facility CDU or cooling loop. Connect Ethernet. Find miner IP, open Bitmain web interface, configure Scrypt merged mining pool URL and LTC/DOGE/BELLS wallet addresses, change default credentials. Verify hashrate reaches 26+ GH/s within 10 minutes.

Major Scrypt merged mining pools accept L9 Hyd 2U hashrate including F2Pool, Poolin, ViaBTC, Prohashing, Litecoinpool. Pool fees typically 0.5 to 2 percent. Verify Bellscoin support before deployment since not all Scrypt pools have added BELLS.

Third party Scrypt firmware support is less mature than SHA-256. Most L9 Hyd 2U operators run stock Bitmain firmware. Some BraiinsOS style tuning has targeted earlier Scrypt hardware but L9 Hyd 2U specific deployment is limited. Plan for stock Bitmain firmware operation.

Pro factors: lower acquisition cost than current generation L11 hydro, 2U rack format matches L11 Hyd 2U for fleet transition flexibility, 50 dB acoustic advantage over air cooled, mature Bitmain firmware ecosystem, 21 units per 42U rack density. Con factors: L11 family delivers 18 to 23 percent better efficiency per megahash, requires external facility hydro infrastructure (L11 HU6 eliminates this), 380 to 415V three phase excludes non industrial facilities. For facilities with existing rack mount hydro infrastructure prioritizing capital efficiency over latest generation performance, the L9 Hyd 2U delivers competitive fleet expansion economics.

For Scrypt family upgrades: L11 Hyd 2U (35 GH/s) drops into the same rack slots with better efficiency, L11 HU6 (33 GH/s) offers integrated all in one cooling eliminating facility hydro infrastructure, air cooled L11 Pro (21 GH/s) and L11 base (20 GH/s) for facility zones without hydro. For algorithm diversification: Antminer S21 XP (270 TH/s), S23 (318 TH/s), or S23E Hyd 2U (865 TH/s) cover SHA-256 Bitcoin with similar three phase hydro deployment. Antminer KS7 (45 TH/s) covers Kaspa KHeavyHash. For quiet Scrypt on separate infrastructure: Fluminer L3 (9.5 GH/s, 45 dB) or Fluminer L1 Pro (6 GH/s, 45 dB). Bitdeer SEALMINER DL1 Air (25 GH/s) provides air cooled vendor diversification. MillionMiner's ASIC hosting service covers turnkey L9 Hyd 2U deployment without facility CapEx.

Get a Quote