Bitmain
Model: Antminer S21 XP+ Hyd
Bitmain's premium S21 generation three phase hydro Bitcoin miner at 500 TH/s, 5,500W, and 11 J/TH efficiency. Positioned as the efficiency bridge between the 13 J/TH S21e series and the newer 9.5 J/TH S23 Hydro series. 380 to 415V three phase industrial power required (not compatible with standard single phase commercial or residential service). Compact 339 x 173 x 207 mm chassis at 13.8 kg allows dense rack deployment. 50 dB chassis operation with external closed loop hydro cooling infrastructure. Launch window late 2024 to early 2025 with ongoing batch shipments through 2026. ±3% hashrate tolerance (485 to 515 TH/s real world output) and ±5% power tolerance (peak draw 5,775W). MillionMiner at $9,500 acquisition cost positions this unit competitively against the newer S23 Hydro 580TH at $14,299 and against the 3U petahash class S21e XP Hyd 3U 860TH at $11,649. 20 to 50 degrees Celsius operating range. Ethernet 10/100M management. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.
Vyberte dostupnost
Množství
$9,500.00
Buying 10 or more? Get custom bulk pricing
Opravdový
Otestovaný hardware
Celosvětově
Celosvětová doprava
Podpora
Odborníci na těžbu
Těžební výkon
500 TH/s
Výkon
5500 W
Účinnost
11.00 J/TH
Hluk
50 dB
Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.
| Období | Denně | Týdenní | Měsíční |
|---|---|---|---|
|
Příjmy
|
$18.75 | $131.25 | $562.50 |
|
Elektrická energie
|
-$10.56 | -$73.92 | -$316.80 |
|
Zisk
|
$8.19 | $57.33 | $245.70 |
Using 0.080 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: May 09, 2026. Estimates at $0.08/kWh.
Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.
Connect PSU to miner and plug into the outlet
Připojte ethernetový kabel k vašemu routeru nebo switchi
Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP
Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit
Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.
Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.
Bridge efficiency between legacy S21e (13 J/TH) and flagship S23 Hydro (9.5 J/TH). Strong economic fit for operators balancing efficiency and acquisition cost.
339 x 173 x 207 mm at 13.8 kg. No 3U rack hardware required. 18 units per 100 kW panel produce 9.0 PH/s aggregate.
Between the S23 Hydro 580TH ($14,299) and the S21e XP Hyd 3U 860TH ($11,649). $9,500 acquisition cost with strong efficiency.
Tell us what you need and our team will send you a customized ASIC miner hosting quote
Tell us your miner model (or quantity), your target electricity rate, and we will send a hosting cost breakdown within 24 hours.
500 TH/s of SHA-256 hashrate at 5,500W continuous power draw and 11 J/TH efficiency. Bitmain's ±3% hashrate tolerance means real world output ranges 485 to 515 TH/s. ±5% power tolerance means wall draw can reach 5,775W at peak. This is Bitmain's premium S21 generation three phase hydro option, positioned between the legacy S21e series (13 J/TH) and the newer S23 Hydro flagship (9.5 J/TH). For operators balancing efficiency and acquisition cost on 2 to 3 year deployment horizons, the 11 J/TH efficiency delivers strong economic fit without the premium pricing of S23 generation hardware.
Ne, ale představuje vysokou účinnost v prémiové střední třídě. Aktuální nejvyšší účinnostní třída (9,5 J/TH): S23 Hydro 580TH a S23 Hyd 3U 1,16 PH/s. Prémiová střední třída (11 J/TH): S21 XP+ Hyd 500TH (tento produkt). Silná střední třída (12 J/TH): S21 XP Hydro 473TH. Oprávněná třída (13 až 15 J/TH): S21e XP Hyd 3U 860TH, S21+ Hydro 395TH, vzduchem chlazené S23. Pro operátory, kteří upřednostňují absolutní účinnost bez ohledu na cenu pořízení, vítězí S23 Hydro 580TH. Pro operátory, kteří musí vyvažovat účinnost s rozpočtem na hardware, je model S21 XP+ Hyd 500TH konkurenceschopnou volbou.
380 to 415V three phase industrial power service. At 415V three phase: approximately 13 amps per phase continuous, 23 amps per phase at peak draw. At 380V three phase: approximately 14 amps per phase continuous. Requires dedicated 20 amp three phase breakers minimum. Connector specification: OneMiners batch documentation references P33 connector 6 pin with notation "1-3 phases like S21 miner" suggesting possible single phase compatibility in certain batch configurations. BT-Miners explicitly requires three phase only deployment. Recommend verifying connector and phase requirements with MillionMiner before ordering for single phase deployment scenarios.
S23 Hydro 580TH delivers the flagship position at $14,299 with 16 percent more hashrate and 14 percent better efficiency (9.5 versus 11 J/TH). S21 XP+ Hyd 500TH at $9,500 represents the value position at 50 percent lower acquisition cost per unit. Economic breakeven calculation: at $0.07 per kWh industrial rates, the efficiency gap translates to approximately $0.75 daily electricity difference per equivalent output unit. Across a 10 unit deployment over 3 years, the S23 Hydro savings total approximately $8,200 versus S21 XP+ Hyd 500TH. The $4,799 price differential per unit ($47,990 across 10 units) would take approximately 6 years to recover through pure efficiency savings. Accounting for the additional hashrate revenue on the S23 Hydro, break even compresses to 24 to 36 months depending on BTC price scenarios. Deployment horizons beyond 3 years favor S23 Hydro. Below 24 months or at meaningful price differentials beyond the illustrative $4,800 gap, the S21 XP+ Hyd value play strengthens.
Different form factors and efficiency tiers. S21 XP+ Hyd 500TH (this product): 500 TH/s at 5,500W and 11 J/TH in compact standalone chassis ($9,500). S21e XP Hyd 3U: 860 TH/s at 11,180W and 13 J/TH in 3U rack format ($11,649). Per dollar of hashrate: $19 per TH for S21 XP+ Hyd versus $13.54 per TH for S21e XP Hyd 3U (legacy 3U wins on acquisition cost per TH). Per watt efficiency: S21 XP+ Hyd 500TH wins at 11 versus 13 J/TH. For operators optimizing hashrate per dollar spent and willing to accept 18 percent worse efficiency, the 3U unit provides more hashrate per dollar. For operators optimizing long term electricity efficiency, the S21 XP+ Hyd 500TH wins. For operators needing compact chassis rather than 3U rack format, the S21 XP+ Hyd 500TH is the only choice.
External closed loop water cooling system with standard industrial components. Each unit generates approximately 5.5 kW thermal load (18,760 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for aggregate thermal load, inline particulate filtration, automated flow monitoring, and temperature management at inlet and outlet. Same cooling infrastructure requirements as the S23 Hydro 580TH standalone. Multi unit deployments scale cooling proportionally through manifold distribution with individual unit isolation valves.
339 x 173 x 207 mm chassis at 13.8 kg. Compact standalone format identical to the S21 XP Hydro 473TH and S21 XP+ Hydro 395TH universal voltage siblings (different cooling and power inlet configurations across variants). Fits on standard shelves, in compact rack configurations, or in dedicated 19 inch server racks depending on facility design. Does not require specialized 3U rack mount hardware of the S21e XP Hyd 3U or S23 Hyd 3U flagships. For operators with limited rack infrastructure or preferring flexible mounting options, the compact chassis is a deployment advantage.
Mining Now April 2026 at $0.07 per kWh: $16.30 daily revenue, $9.24 electricity, $7.23 daily net profit. MillionMiner $0.08 per kWh onsite calculator: $16.30 daily revenue, $10.56 electricity, $5.74 daily net. OneMiners April to August 2025 data at $0.04 per kWh industrial hosting: $19 to $22 daily earnings, averaging $19.28. ROI estimates: 1,045 to 1,983 days at $0.07 per kWh per Mining Now, compressed to 7 to 14 months at $0.04 per kWh industrial hosting per OneMiners. At BTC prices above $160,000, daily profit projections exceed $12 per unit at commercial electricity rates.
Generally no. The 380 to 415V three phase power requirement excludes most residential electrical service in most regions. Some advanced home deployments with three phase service (rare residential configurations or converted commercial buildings) and dedicated mechanical spaces can support S21 XP+ Hyd 500TH operation. The 5.5 kW thermal load requires meaningful home cooling infrastructure. For standard residential mining on single phase voltage, the Antminer S21 XP 270TH air cooled or S21+ Hydro 395TH universal voltage options represent the practical residential ceiling. Note: some OneMiners batch documentation references P33 connector supporting 1 to 3 phases which may enable single phase deployment of specific S21 XP+ Hyd 500TH batches. Verify connector and phase compatibility with MillionMiner before committing to single phase deployment.
50 dB chassis noise, effectively silent due to the absence of cooling fans. External cooling infrastructure generates acoustic signature separately. Pumps typically run 45 to 55 dB. Dry coolers typically run 55 to 70 dB depending on airflow requirements. Professional hydro cooled mining facilities isolate miner deployment space from cooling plant locations to manage total acoustic signature. Total deployment noise depends substantially on cooling infrastructure design rather than miner chassis.
Industrial deployment with three phase power and hydro cooling infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with appropriate breaker capacity (20 amp three phase minimum). Step two: install and commission external hydro cooling loop with pumps, plumbing, coolant fill, dry cooler infrastructure, and temperature monitoring. Step three: rack or shelf mount the S21 XP+ Hyd units and connect water inlet/outlet fittings to manifold system. Verify zero leaks before energizing. Step four: connect three phase power cables (verify connector type against MillionMiner documentation) and Ethernet management cable. Step five: power on, allow coolant flow to stabilize, find miner IP through router DHCP, open Bitmain web interface, configure pool URL and Bitcoin wallet, verify hashrate reaches 485+ TH/s within 10 to 15 minutes.
Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.
20 to 50 degrees Celsius ambient operating range at 10 to 90 percent humidity. Inlet water temperature constraints typical of Bitmain hydro hardware apply (consult Bitmain's user manual for specific constraints on this unit). External dry cooler specifications tie maximum facility ambient temperature to outlet water temperature. Cooling loop design must account for these constraints across seasonal temperature variation.
Standardní údržba hydrochlazení. Týdenní vizuální kontrola vodovodních spojů na úniky nebo korozi. Měsíční testování kvality chladicí kapaliny. Každých 12 až 24 měsíců kompletní výměna chladicí kapaliny v závislosti na chemii kapaliny a kvalitě vody. Čtvrtletní kontrola čerpadel a suchých chladičů. Výmena inline filtru, když tlakový rozdíl překročí specifikaci. Míra selhání hashboardů u hydro jednotek je podstatně nižší než u vzduchem chlazených ekvivalentů. Rozpočet 3 až 5 procent z pořizovací ceny ročně na rezervy pro údržbu.
Bitmain 365 day factory warranty on the complete machine covering manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. MillionMiner routes warranty claims through direct Bitmain channels. Document coolant testing schedule and maintenance records to protect warranty coverage.
Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record and supports merged mining. AntPool is the native Bitmain ecosystem pool with deep firmware integration. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives products. For fleet deployments above 5 PH/s (equivalent to 10+ units), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates.
Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power and hydro cooling infrastructure capable of supporting S21 XP+ Hyd deployments. Hosted deployment eliminates facility infrastructure CapEx and leverages MillionMiner's negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At these hosted rates, OneMiners documents $19 to $22 daily earnings per unit in April to August 2025 data. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.
CapEx beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), hydro cooling loop and dry cooler infrastructure ($5,000 to $20,000 per rack), basic rack or shelf hardware ($200 to $1,500). Annual OpEx per unit at 5.5 kW continuous: electricity at $3,854 at $0.08 per kWh, $3,373 at $0.07 per kWh, $1,927 at $0.04 per kWh industrial hosting rates. Water glycol coolant maintenance ($100 to $200 annually per unit). Spare parts reserves (3 to 5 percent of acquisition annually). 3 year TCO per unit at $0.07 per kWh self hosted: approximately $9,500 hardware plus $10,120 electricity plus $800 maintenance equals $20,420 total. 3 year gross revenue at $0.07 per kWh profitability: approximately $8,000 to $12,000.
Upon late 2024 to early 2025 launch, the S21 XP+ Hyd 500TH represented Bitmain's highest efficiency standalone hydro option outside the 3U petahash class. The January 2026 launch of the S23 Hydro 580TH at 9.5 J/TH captured the standalone efficiency flagship position. The S21 XP+ Hyd 500TH now sits in the premium mid tier: meaningfully better efficiency than legacy S21 generation hardware (S21e at 13 J/TH, S21+ Hydro at 15 J/TH), meaningful acquisition cost savings versus S23 generation hardware. For operators with balanced efficiency and acquisition cost priorities over 2 to 3 year deployment horizons, the S21 XP+ Hyd 500TH maintains strong economic fit despite no longer holding flagship status.
V rámci generace Bitmain S23 (novější, s vyšší účinnost): S23 Hydro 580TH samostatný pro prémiové kompaktní hydro, S23 Hyd 3U 1,16 PH/s pro petahash 3U, S23 Air 318TH pro chlazení vzduchem, S23 Immersion 442TH pro nasazení v nádrži, S23E Hyd 2U 865TH jako alternativa pro tier. V rámci generace Bitmain S21: S21 XP Hydro 473TH pro univerzální napětí kompaktní hydro, S21+ Hydro 395TH jako nižší účinná možnost s univerzálním napětím, S21e XP Hyd 3U 860TH pro 3U rack formát s vyšší hodnotou, S21e XP Hyd 430TH jako předchozí generace samostatně. Pro operátory diverzifikující napříč výrobci: Whatsminer M73S+ 540TH nabízí alternativu s rackem MicroBT, Whatsminer M79S 1,35 PH/s představuje hydro s vysokým výkonem. Diverzifikace flotily podle algoritmu: Antminer KS7 pro Kaspa, Antminer L11 pro Litecoin a Dogecoin, IceRiver AE3 pro Aleo, Antminer Z15 pro Zcash. Pro modulární infrastrukturu s dlouhou životností: Proto Rig 819 TH/s poskytuje alternativu s 10+letým rámečkem od společnosti Block. Služba hostování ASIC od MillionMiner přijímá jednotky S21 XP+ Hyd 500TH za dohodnuté průmyslové tarify za elektřinu.