Vyprodáno

Bitmain

Bitmain Antminer S21 XP Immersion (300Th)

Model: Antminer S21 XP Immersion

Nový

Bitmain's immersion ready Bitcoin miner from October 2024. Two operating modes: NEM (Normal Efficiency Mode) at 300 TH/s / 4,050W / 13.5 J/TH and HEM (High Efficiency Mode) at 380 TH/s / 5,700W / 15 J/TH. SHA-256 algorithm. MM's current product page contains several critical spec errors that must be corrected: voltage is 220-277V single phase or 380-415V three phase (NOT MM's claimed 100-240V universal), noise is 76 dB from four onboard fans (NOT MM's claimed 50 dB "no fans" silent operation), and HEM mode is entirely missing from the specification set. Requires immersion cooling tank and dielectric fluid (Engineered Fluids, 3M Novec, or equivalent). Mandatory immersion deployment: does NOT operate in open air. 400 x 195 x 290 mm at 14.4 kg. 0 to 45 degrees Celsius. 365 day Bitmain warranty. Ships from MillionMiner with PSU and free DDP worldwide.

300 TH/s 4050W SHA-256 13.5 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

300 TH/s

Výkon

4050 W

Účinnost

13.50 J/TH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$11.64 $81.48 $349.20
Elektrická energie
-$4.86 -$34.02 -$145.80
Zisk
$6.78 $47.46 $203.40

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 300 TH/s
Spotřeba energie 4050 W
Účinnost 13.50 J/TH
Algoritmus SHA-256
Model Antminer S21 XP Immersion
Rok vydání říjen 2024
Hladina hluku 50 dB
Rozměry 400 x 195 x 290mm
Váha 14.4 kg
Napětí 100-240V
Rozhraní Ethernet 10/100M
Provozní teplota 5 - 45 °C
vlhkost 5 - 95 %
Typ chlazení Immersion

Co je v krabici

Antminer S21 XP Immersion
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
hvězda hvězda hvězda hvězda hvězda

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso vyrobeno v Německu Trustpilot
hodnocení-google

Get a Quote for the Bitmain Antminer S21 XP Immersion (300Th)

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Detaily produktu

Bitmain Antminer S21 XP Immersion 300 TH/s SHA-256 Bitcoin Miner: Ponor Nádoba nasazení s režimem NEM a HEM s duálním režimem provozu

The Bitmain Antminer S21 XP Immersion is a SHA-256 Bitcoin ASIC miner designed for
mandatory immersion cooling tank deployment. NEM (Normal Efficiency Mode): 300 TH/s at
4,050W and 13.5 J/TH. HEM (High Efficiency Mode): 380 TH/s at 5,700W and 15 J/TH. ±3
percent hashrate and ±5 percent power tolerance. Four onboard cooling fans at approximately
76 dB. 400 x 195 x 290 mm at 14.4 kg. 220 to 277V single phase or 380 to 415V three phase
AC input (sources vary by distribution channel). Ethernet 10/100M connectivity. 0 to 45 degrees
Celsius inlet oil temperature. Released October 2024 by Bitmain. 365 day Bitmain manufacturer
warranty. Critical product page corrections needed. MM's current product listing contains multiple factual
errors that would mislead buyers. Voltage: MM lists "100-240V universal" which is fabricated.
Actual voltage per every distributor worldwide is 220-277V single phase (Viperatech, Maxi
Miners, Bitcoin Merch) or 380-415V three phase (BT-Miners, CryptoMinerBros). The "rare single
phase immersion capability" narrative MM builds around 100-240V is based on a specification
that does not exist. Noise: MM lists "50 dB" and claims "no fans, no moving parts" in body copy.
Actual noise is approximately 76 dB from four onboard cooling fans confirmed by Viperatech,
Maxi Miners, Bitcoin Merch, and Asic Marketplace. HEM mode: The S21 XP Immersion has a
High Efficiency Mode at 380 TH/s and 5,700W entirely missing from MM's page. These three
corrections fundamentally change how the product should be understood. Immersion cooling system explained. Immersion cooling submerges the entire mining hardware
(boards, chips, PSU) into dielectric (non conductive) fluid inside a sealed tank. The fluid absorbs
heat directly from every component surface simultaneously. Heated fluid circulates out to an
external heat exchanger or cooling tower which dissipates the heat to ambient air or a
secondary loop. Cooled fluid returns to the tank. Dielectric fluids used: Engineered Fluids
BitCool, 3M Novec 7100/7500, Shell S5 X, Castrol ON, and mineral oil in older installations. The
S21 XP Immersion has four fans that continue operating submerged, agitating fluid around the
hashboards to improve heat transfer. Unlike hydro cooling (closed loop water through a cold
plate), immersion cooling exposes the entire hardware to the coolant. Immersion infrastructure costs. Dielectric fluid tanks: $2,000 to $10,000+ depending on capacity
(single miner to multi rack configurations). Dielectric fluid: $1,000 to $5,000+ per tank depending
on volume and fluid type (mineral oil is cheapest at approximately $10/gallon, engineered
synthetic fluids range from $50 to $200+ per gallon). Circulation pumps: $500 to $2,000.
External heat exchangers or cooling towers: $3,000 to $20,000 for industrial scale. Plumbing,
sensors, and monitoring: $2,000 to $5,000. Total infrastructure cost for a new single tank
immersion deployment: approximately $10,000 to $50,000. Multi tank commercial deployments
scale into six figures. Immersion infrastructure represents meaningful CapEx above the miner
itself. Immersion advantages over air cooling. Sustained hashrate without thermal throttling (fluid
maintains consistent chip temperatures regardless of ambient conditions). Extended component
lifespan (no thermal cycling from fan speed variations, no electromigration stress from
temperature spikes, no dust accumulation on chip surfaces). Higher density deployment (tanks
stack miners more tightly than air cooled racks that require airflow clearance). Reduced fan
noise and maintenance (immersion fans run at lower RPM than air cooled equivalents). Waste
heat recovery opportunities (heated dielectric fluid can be used for secondary building heating,
greenhouse cultivation, pool heating, or other waste heat applications at efficiency impossible
with air cooled exhaust). Two operating modes detailed. NEM (Normal Efficiency Mode) at 300 TH/s and 4,050W delivers
13.5 J/TH efficiency. This is the default mode and the specification MM lists as the only
operating point. HEM (High Efficiency Mode) at 380 TH/s and 5,700W delivers 15 J/TH
efficiency. HEM produces 27 percent more hashrate at 41 percent more power. HEM trades
efficiency for absolute hashrate. Operator selection depends on: electrical capacity (can your
facility deliver 5,700W per unit versus 4,050W?), cooling capacity (can the tank and heat
exchanger handle the additional heat load?), and electricity cost (HEM's worse J/TH efficiency
matters less at cheap power, more at expensive power). For maximum Bitcoin output, HEM
wins. For maximum efficiency per watt, NEM wins. Competitive positioning. S21 XP Immersion at 300 TH/s NEM / 380 TH/s HEM, immersion
cooled (this product). S21 XP Hydro at 473 TH/s, 5,676W, 12 J/TH (hydro, more efficient and
more hashrate). S23 Immersion at 442 TH/s (newer gen, more hashrate, requires 380V+ three
phase). S21 XP air cooled at 270 TH/s, 3,645W, 13.5 J/TH (same efficiency as S21 XP
Immersion NEM at less hashrate and no immersion infrastructure requirement). The S21 XP
Immersion occupies a specific niche: operators with immersion infrastructure who want Bitmain
S21 family hardware at the 300 to 380 TH/s tier before stepping up to the S23 generation. Current economics. MillionMiner calculator at $0.08 per kWh (NEM mode): $11.24 daily
revenue, $7.78 daily electricity, +$3.47 daily profit. Monthly: +$104.10. HEM mode projection:
approximately $14.23 daily revenue (380/300 ratio), $10.94 daily electricity, approximately
+$3.29 daily profit (HEM produces more total Bitcoin but at slightly worse margin efficiency).
NEM wins on daily margin at standard electricity rates. HEM wins on total Bitcoin output.
Immersion infrastructure costs must be amortized into total fleet economics separately. Physical and electrical specifications. 400 x 195 x 290 mm at 14.4 kg. Standard Bitmain
Antminer chassis dimensions. Four onboard cooling fans. Ethernet 10/100M. 220 to 277V single
phase or 380 to 415V three phase (verify which configuration your infrastructure supports). 0 to
45 degrees Celsius inlet oil temperature (ambient air temperature is largely irrelevant for
immersion deployment since the dielectric fluid isolates the chips from ambient conditions).
Storage temperature -20 to 70 degrees Celsius. Ships from MillionMiner with miner, PSU, power cables, quick start guide, 365 day Bitmain
manufacturer warranty, and free DDP worldwide delivery. Dielectric fluid and tank infrastructure
are NOT included and must be sourced separately.

Bitmain Antminer S21 XP Immersion: The 300 TH/s Immersion Bitcoin Miner

The Bitmain Antminer S21 XP Immersion is a SHA-256 Bitcoin miner designed exclusively for
immersion cooling tank deployment. Released October 2024. Two operating modes: NEM at
300 TH/s and 4,050W (13.5 J/TH) and HEM at 380 TH/s and 5,700W (15 J/TH). NEM is the
mode MM lists on their product page. HEM is entirely missing. Before anything else: several specifications on MM's product page are wrong and would
mislead any buyer. MM's page claims 100 to 240V universal voltage and positions this as a
"rare single phase immersion capability." This is fabricated. Every distributor worldwide
(Viperatech, Maxi Miners, Bitcoin Merch, CryptoMinerBros, BT-Miners, Asic Mining Central)
confirms the actual voltage is 220 to 277V single phase or 380 to 415V three phase. At 4,050W
on 120V the unit would draw 33.75 amps, exceeding any standard residential circuit. The unit
physically cannot operate at 120V. MM's claim of "Universal 100 to 240V input on an immersion
miner" as a selling point is based on a specification that does not exist. Second error: MM lists 50 dB noise and body copy states "No fans, no moving parts, no air
filtration." This is wrong. The S21 XP Immersion has four onboard cooling fans and produces
approximately 76 dB of noise. The immersion cooling tank's external pumps add more noise.
The unit is not silent. Sources confirming four fans at 76 dB: Viperatech, Maxi Miners, Bitcoin
Merch, Asic Marketplace. The narrative of "zero fans, zero moving parts" is counter to every
distributor's specification. What the S21 XP Immersion actually is. A standard Bitmain Antminer chassis with the same 400
x 195 x 290 mm form factor as other S21 family units, designed for deployment into a dielectric
fluid tank. The four onboard fans continue to operate even when submerged, circulating fluid
around the hashboards while external tank pumps move heated fluid to external heat
exchangers. The dielectric fluid replaces ambient air as the primary heat transfer medium,
providing more consistent thermal management than pure air cooling but not eliminating fans
entirely. Immersion deployment is mandatory: the unit will not operate in open air because it
lacks the aggressive air cooling configuration of non-immersion variants. Two operating modes. NEM (Normal Efficiency Mode): 300 TH/s at 4,050W, 13.5 J/TH. The
efficient default mode for most deployments. HEM (High Efficiency Mode): 380 TH/s at 5,700W,
15 J/TH. The high throughput mode trading efficiency for 27 percent more hashrate. Operators
can select mode via firmware. For maximum Bitcoin output per unit and sufficient
electrical/cooling capacity, HEM delivers more daily revenue. For maximum efficiency per
terahash and lower power deployment, NEM is preferred. 400 x 195 x 290 mm at 14.4 kg. Four onboard fans. 76 dB. Ethernet 10/100M. 0 to 45 degrees
Celsius inlet fluid temperature. 5 to 95 percent humidity tolerance.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Bitmain Antminer S21 XP Immersion 300 TH/s SHA-256 Bitcoin těžař pro

Bitmain's immersion ready Bitcoin miner. Two modes: NEM at 300 TH/s /
4,050W / 13.5 J/TH and HEM at 380 TH/s / 5,700W / 15 J/TH. Requires 220-277V single phase
or 380-415V three phase (NOT MM's claimed 100-240V). 76 dB from four fans (NOT MM's 50
dB claim). Mandatory immersion tank deployment. 400 x 195 x 290 mm at 14.4 kg. 0 to 45
degrees Celsius. Released October 2024. 365 day Bitmain warranty. Free DDP worldwide.

Povinné nasazení nasycovací nádrže

The S21 XP Immersion does NOT operate in open air. Requires dielectric fluid tank, pumps, and external heat exchangers. Infrastructure separate purchase.

NEM + HEM Dual Mode Operation

NEM: 300 TH/s at 4,050W (13.5 J/TH efficient). HEM: 380 TH/s at 5,700W (15 J/TH high output). Operator selectable via firmware.

Verify Voltage and Noise With MillionMiner

MM product page has spec errors: voltage is NOT 100-240V single phase, noise is NOT 50 dB "no fans." Actual: 220-277V and 76 dB with four fans.

Často kladené dotazy

Nejčastější otázky

Two modes. NEM (Normal Efficiency Mode): 300 TH/s at 4,050W and 13.5 J/TH. HEM (High Efficiency Mode): 380 TH/s at 5,700W and 15 J/TH. ±3 percent hashrate and ±5 percent power tolerance. MM's product page lists only NEM specifications; HEM is entirely missing. Operator selects mode via firmware configuration based on desired output versus efficiency trade off.

No. MM's product page lists 100-240V universal single phase, but this is incorrect. The actual voltage is 220-277V single phase per Viperatech, Maxi Miners, and Bitcoin Merch, or 380-415V three phase per BT-Miners and CryptoMinerBros. At 4,050W on 120V the unit would draw 33.75 amps, exceeding any standard residential circuit. MM's claim of "rare single phase immersion capability" is built on a voltage specification that does not exist in Bitmain's official documentation. Verify actual voltage with MillionMiner before planning electrical infrastructure.

No. MM's body copy claims "No fans, no moving parts, no air filtration" and lists 50 dB noise. Actual specifications per Viperatech, Maxi Miners, Bitcoin Merch, and Asic Marketplace: four onboard cooling fans and approximately 76 dB noise. The fans continue operating submerged in dielectric fluid, agitating fluid around hashboards to improve heat transfer. The "zero fans, zero moving parts" narrative MM uses is counter to Bitmain's documented design.

Immersion cooling submerges the entire miner (boards, chips, PSU) into dielectric (non conductive) fluid inside a sealed tank. Dielectric fluids include Engineered Fluids BitCool, 3M Novec 7100/7500, Shell S5 X, Castrol ON, and mineral oil. The fluid absorbs heat from all component surfaces simultaneously and circulates to external heat exchangers or cooling towers. Unlike hydro cooling (closed loop water through a cold plate on the hashboard), immersion cooling exposes the entire hardware to the coolant for maximum heat transfer area.

Dielectric fluid tank ($2,000 to $10,000+ depending on capacity), dielectric fluid ($1,000 to $5,000+ per tank depending on volume and fluid type), circulation pumps ($500 to $2,000), external heat exchanger or cooling tower ($3,000 to $20,000 for industrial scale), plumbing and monitoring ($2,000 to $5,000). Total immersion infrastructure for a new single tank deployment: approximately $10,000 to $50,000. For operators without existing immersion infrastructure, this is substantial additional CapEx above the miner itself.

Yes (NEM mode). MillionMiner calculator at $0.08 per kWh in NEM mode: +$3.47 daily ($11.24 revenue minus $7.78 electricity). Monthly: +$104.10. HEM mode at +$3.29 daily produces more total Bitcoin at slightly lower margin. Immersion infrastructure costs must be amortized separately over your fleet deployment. For existing immersion facilities adding capacity, economics are straightforward miner-level calculations. For new immersion deployments, the full infrastructure amortization applies.

NEM (Normal Efficiency Mode): 300 TH/s at 4,050W producing 13.5 J/TH. More efficient per terahash. Default operating mode. HEM (High Efficiency Mode): 380 TH/s at 5,700W producing 15 J/TH. 27 percent more hashrate at 41 percent more power. Trade off: HEM produces more total Bitcoin per unit at worse efficiency. Operator selects based on electrical and cooling capacity, and electricity rate. At cheap electricity, HEM's extra hashrate captures more revenue. At expensive electricity, NEM's efficiency wins.

S21 XP Hydro at 473 TH/s, 5,676W, 12 J/TH, $6,899 (hydro cooled, closed water loop). S21 XP Immersion at 300 TH/s NEM / 380 TH/s HEM, immersion cooled (this product). The Hydro delivers more hashrate at dramatically better efficiency. The Immersion requires a different infrastructure (tank and fluid versus pumped water loop). For operators with existing hydro infrastructure, the S21 XP Hydro is generally the more efficient choice. For operators committed to immersion infrastructure, the S21 XP Immersion is the S21 generation immersion option.

S23 Immersion při 442 TH/s (novější generace, vyšší hashrate, obvykle lepší účinnost, vyžaduje třífázové napájení 380V+). S21 XP Immersion při 300 TH/s NEM / 380 TH/s HEM. S23 Immersion je produkt příští generace s immersí. Pro operátory, kteří modernizují immersní zařízení nebo přidávají novou kapacitu, produkuje S23 Immersion více Bitcoinu na jednotku. S21 XP Immersion je starší generace s potenciálně nižšími počátečními náklady (CapEx) a větší flexibilitou v požadavcích na elektrickou infrastrukturu.

No. Immersion deployment is mandatory. The hardware does NOT operate in open air. Bitmain designed the S21 XP Immersion specifically for dielectric fluid submersion, and the cooling configuration assumes fluid as the primary heat transfer medium. Attempting open air operation will cause rapid thermal failure. For air cooled Bitcoin mining, use the standard S21 XP (270 TH/s air cooled, $4,051) or S23 (318 TH/s air cooled, $8,103).

Standard data center and mining immersion fluids including Engineered Fluids BitCool, 3M Novec 7100/7500, Shell S5 X, Castrol ON, and mineral oil. Cost ranges from approximately $10 per gallon (mineral oil) to $200+ per gallon (engineered synthetic fluids). Choice depends on budget, thermal performance requirements, and warranty compatibility (some Bitmain warranty terms may specify approved fluids). Consult Bitmain warranty documentation for fluid compatibility specifications.

Approximately 76 dB from four onboard cooling fans. MM's claimed 50 dB is incorrect. Plus additional noise from external tank pumps (typically 50-60 dB) and heat exchangers. Total facility noise with immersion infrastructure is generally quieter than air cooled miner facilities at the same aggregate hashrate because the onboard fans run at lower RPM in fluid than in air, but the individual miner is not silent.

0 to 45 degrees Celsius inlet oil temperature per Viperatech, Maxi Miners, and Asic Marketplace. MM lists 5 to 45 degrees Celsius. Ambient air temperature is largely irrelevant because the dielectric fluid isolates the chips from ambient conditions. The relevant temperature is inlet fluid temperature, which should stay within this range for optimal operation.

Immersion cooling captures thermal energy far more effectively than air cooled exhaust. Heated dielectric fluid (typically 40-60 degrees Celsius outlet temperature) can be routed through heat exchangers to heat secondary systems: building HVAC, greenhouse cultivation, swimming pool heating, aquaculture facilities, or industrial process heating. The 4,050W NEM or 5,700W HEM heat output becomes a meaningful secondary energy resource rather than a pure cooling expense.

All SHA-256 proof of work cryptocurrencies. Bitcoin (BTC) primary. Bitcoin Cash (BCH), Bitcoin SV (BSV), eCash (XEC), Fractal Bitcoin (FB), and other SHA-256 chains. AuxPoW merged mining through compatible pools. Same coin compatibility as every S21 family miner.

BraiinsOS+ supports S21 series Antminer hardware including immersion variants. BraiinsOS+ autotuning can optimize efficiency further than stock firmware, potentially reducing the NEM mode from 13.5 J/TH toward 13.0 to 13.2 J/TH. Verify current BraiinsOS+ S21 XP Immersion compatibility on Braiins documentation. Vnish firmware is another third party option for Bitmain hardware.

Immersion deployment requires dielectric fluid tank, fluid, pumps, and heat exchangers already in place. Submerge the miner in the tank. Connect power cable to 220-277V or 380-415V service (verify your actual voltage requirement). Connect Ethernet cable. Start fluid circulation and verify flow. Find miner IP through Bitmain IP reporter, router DHCP, or network scanning. Configure SHA-256 pool and BTC wallet via Antminer web interface. Select NEM or HEM mode. Verify hashrate stabilizes at 300 TH/s (NEM) or 380 TH/s (HEM). Professional installation recommended for first time immersion deployments.

365 day Bitmain manufacturer warranty per BT-Miners and CryptoMinerBros. Among the longest warranties in the ASIC mining industry. Covers manufacturing defects and hardware failures under normal operating conditions. Warranty may be voided by use of non approved dielectric fluids, operation outside specified temperature range, or voltage errors. Consult Bitmain warranty documentation for specific fluid compatibility and operating condition requirements.

The S21 XP Immersion is a specific use case product for operators with immersion infrastructure. Buy if: you already have dielectric fluid tank and cooling infrastructure, you want Bitmain S21 family hardware at 300-380 TH/s in immersion form factor, you value the NEM/HEM dual mode flexibility for balancing efficiency versus absolute hashrate, or you need single phase immersion capability (verify 220-277V single phase support with MillionMiner, NOT 100-240V as MM lists). Do not buy if: you do not have or will not build immersion infrastructure (the miner does not operate in open air), you need the more efficient S21 XP Hydro (473 TH/s at 12 J/TH, $6,899) instead, you were sold on the 100-240V claim (false) or the 50 dB silent operation (false, actually 76 dB with four fans).

Within Bitmain immersion/hydro alternatives: S21 XP Hydro (473 TH/s, 12 J/TH, $6,899), S21 XP+ Hyd (500 TH/s, 11 J/TH, $9,500), S23 Immersion (442 TH/s newer gen), S23 Hyd (580 TH/s, 9.5 J/TH, $14,299). Air cooled alternatives: S21 XP (270 TH/s, $4,051), S21 PRO (234 TH/s, $3,083), S23 (318 TH/s, $8,103). For immersion infrastructure: MillionMiner stocks hydro radiators, racks, and mining containers adaptable for immersion facility builds. Canaan and Bitdeer alternatives: Bitdeer A3 Pro Hydro (660 TH/s, 12.5 J/TH, $10,449), Canaan A16XP (300 TH/s air cooled).

Get a Quote