Skladem

Bitmain

Bitmain Antminer S21e XP Hydro (860Th/s)

Model: Antminer S21e XP Hydro

Nový

Bitmain's prior generation 3U petahash class hydro cooled Bitcoin miner, delivering 860 TH/s SHA-256 hashrate at 11,180W power draw and 13 J/TH efficiency. Model U3S21EXPH announced September 2024 with shipping from January 2025. Positioned directly below the current generation S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) at significantly lower acquisition cost, making the S21e XP Hyd 3U the strongest per dollar of hashrate value play in the 3U petahash tier. 380 to 415V three phase industrial power with approximately 24 amp maximum current draw. 3U rack mount format in 900 x 486 x 132 mm chassis at approximately 50 kg deployed weight. 50 dB chassis noise (external cooling infrastructure separate). 20 to 50 degrees Celsius operating range. External closed loop hydro cooling with dry cooler or heat exchanger infrastructure rated for 11.2 kW thermal load per unit. ±3% hashrate tolerance means real output 834 to 886 TH/s. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.

860 TH/s 11180W SHA-256 13 J/TH

Vyberte dostupnost

Množství

Celková cena

$11,649.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bankovní převod | BTC | ETH | USDT

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

860 TH/s

Výkon

11180 W

Účinnost

13.00 J/TH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$33.36 $233.52 $1,000.80
Elektrická energie
-$13.42 -$93.94 -$402.60
Zisk
$19.94 $139.58 $598.20

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 860 TH/s
Spotřeba energie 11180 W
Účinnost 13.00 J/TH
Algoritmus SHA-256
Model Antminer S21e XP Hydro
Rok vydání Jan 2024
Hladina hluku 50 dB
Rozměry 900 x 486 x 132mm
Váha 18 kg
Napětí 380-415V
Rozhraní Ethernet 10/100M
Provozní teplota 20 - 50 °C
vlhkost 10 - 90 %
Typ chlazení Hydro
Formát stojanu 3U

Co je v krabici

Antminer S21e XP Hydro
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
hvězda hvězda hvězda hvězda hvězda

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso vyrobeno v Německu Trustpilot
hodnocení-google

Get a Quote for the Bitmain Antminer S21e XP Hydro (860Th/s)

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Detaily produktu

Bitmain Antminer S21e XP Hydro 860 TH/s 3U Prior Generation Hydro Cooled Bitcoin Miner: Complete Specifications, Value Positioning, and Deployment Analysis

Bitmain Antminer S21e XP Hydro 3U při 860 TH/s je předchozí generace petahash třídy 3U stojanu s hydrochladičem na těžbu Bitcoinů, nyní zastává hodnotovou pozici v řadě produktů Bitmainu, zatímco současná generace S23 Hyd 3U získává status vlajkové lodě. Oficiální modelové číslo Bitmain U3S21EXPH, oznámeno v září 2024 s dávkovým odesláním od ledna 2025. Celkový hashrate 860 TH/s při trvalém výkonu 11 180 W a účinnosti 13 J/TH. Tolerance hashrate ±3 % znamená reálné výstupy v rozmezí 834 až 886 TH/s. Postaveno na čipu SEAL02 v rámci efektivnostní úrovně před generací čipů S23.
Pozice na trhu se od uvedení podstatně změnila. Po oznámení v září 2024 představoval S21e XP Hyd 3U nejvýkonnější jednotku na těžbu Bitcoinů v jedné jednotce od Bitmainu. Uvedení na trh v lednu 2026 s výkonem 1,16 PH/s a 9,5 J/TH změnilo pozici vlajkové lodi, čímž byl S23 Hyd 3U s 1,16 PH/s a 9,5 J/TH postaven na špičku, a S21e XP Hyd 3U se nyní stává hodnotovou volbou v tieru petahashů 3U. Cena MillionMiner kolem 11 649 USD je uprostřed trhu s touto jednotkou, zatímco OneMiners zaznamenávají 10 899 USD (53 procent slevy z původní MSRP 23 230 USD), což odráží tlak na ceny starší generace hardware z minulosti.
Nákupní náklady versus efektivnost určují rozhodování o koupi. Ve srovnání se S23 Hyd 3U (1 160 TH/s při 11 020 W a 9,5 J/TH): S23 nabízí o 35 procent vyšší hashrate a o 27 procent lepší účinnost, což obvykle stojí 2 až 3krát více. Pro nasazení 10 jednotek záleží na ceně elektřiny a dobu nasazení. Při ceně elektřiny 0,04 USD/kWh při průmyslovém hostingu na 3 roky úspory S21e XP Hyd 3U obvykle převáží rozdíly v nákladech na elektřinu během životnosti díky nižší účinnosti. Při ceně 0,08 USD/kWh za elektřinu na podnikové úrovni po 3 letech se však rozdíly v efektivitě promítají do nákladů na elektřinu, což favorizuje novější hardware i přestože má vyšší počáteční náklady.
Matematika nasazení na stojan: 14 jednotek S21e XP Hyd 3U v 42U stojanu produkuje celkový výkon 12,04 PH/s při přibližném celkovém příkonu 156 kW. Stejný formát stojanu, ale přibližně o 4,2 PH/s méně v souhrnném hashrate při stejném výkonu. Na průmyslovém panelu 100 kW: přibližně 8 až 9 jednotek S21e XP Hyd 3U produkujících 6,88 až 7,74 PH/s vs. 9 jednotek S23 Hyd 3U s výkonem 10,44 PH/s při stejném výkonu.
Požadavky na infrastrukturu jsou identické s aktuální generací S23 Hyd 3U: třísfázové průmyslové napájení 380 až 415 V přes industrialní konektor LP34 podle specifikací Bitmainu. Při 415V třífázové napětí: přibližně 15 A na fázi kontinuálně, 25 A na fázi v špičce. Při 380V: cca 17 A na fázi kontinuálně, 29 A v špičce. Maximální odběr proudu dle dokumentace BT-Miners: cca 24 A na jednotku. Vyžaduje speciální třífázové jističe minimálně 32 A. Požadavek na industrialní konektor LP34 vylučuje použití v jednofázových nebo rezidenčních systémech.
Vnější uzavřená vodní chladicí infrastruktura odpovídá požadavkům S23 Hyd 3U. Každá jednotka generuje přibližně 11,2 kW tepelné zátěže (38 144 BTU za hodinu), což vyžaduje cirkulační čerpadla s kapacitou pro celou flotilu, suchý chladič nebo výměník tepla voda-voda s hodnocením odpovídajícím celkové tepelnému zatížení, inline filtrem částic, automatickým monitorováním toku a řízením teploty. U více jednotkových nasazení se chladicí infrastruktura škáluje pomocí rozvodných svorek s oddělitelnými uzavíracími ventily pro servisní přístup na úrovni jednotlivých jednotek bez vypnutí celého systému.
Specifikace provozní teploty: 20 až 50 stupňů Celsia v okolí při vlhkosti 10 až 90 procent. Pří vstupní teplotě vody platí omezení dle specifikací hydrochladičného hardwaru Bitmain. Hluk skříně 50 dB odráží absenci chlazení ventilátory. Externí chladicí infrastruktura přidává oddělený akustický dopad podle typu čerpadla, suchého chladiče a návrhu zařízení. Profesionální hydrochladičná těžební zařízení izolují prostor těžebního zařízení od chladicí stanice, aby řídila celkovou akustickou stopu.
Fyzické rozměry: skříň 900 x 486 x 132 mm, stojan kompatibilní s 19-palcovými servery. Před objednáním ověřte hloubku stojanu (hloubka skříně 900 mm přesahuje standardní hloubku stojanu 1000 mm s minimálním odstupem, může vyžadovat hlubší průmyslové stojany). Standardní Bitmain Ethernet řízení 10/100M s kompatibilitou firmware s nástroji Foreman, Awesome Miner, Hive OS a Braiins OS+. Stejná základna firmware sdílí aktualizace s hydro hardwarem generací S21 a S23.
Analýza ziskovosti k dubnu 2026 odráží hodnotové postavení. Data z Mining Now z února 2026 při ceně elektřiny 0,07 USD/kWh: denní příjem z těžby Bitcoinů 30,81 USD, náklady na elektřinu 18,78 USD, čistý denní zisk 12,03 USD. Kalkulačka MillionMiner při ceně 0,08 USD/kWh: denní příjem 28,02 USD, elektřina 21,47 USD, čistý denní zisk 6,55 USD. Hodnota ASIC mineru při 0,10 USD/kWh: denní zisk 7,26 USD. Data OneMiners z května 2025 při agresivních sazbách hostingu 0,01 USD/kWh: denní výdělek 40 až 50 USD, průměrně 44 USD. Odhad návratnosti se pohybuje od 906 do 1850 dní podle Mining Now při 0,07 USD/kWh, zrychleno přibližně na 12 měsíců při 0,04 USD/kWh podle OneMiners. Při cenách BTC nad 160 000 USD se denní zisky významně zlepšují.
Dodáváno s PSU, 365denní zárukou od továrny Bitmain a zdarma DDP dodáním po celém světě od MillionMiner včetně celního řízení.

Bitmain Antminer S21e XP Hydro 860 TH/s 3U: The Value Play in the Petahash

The S21e XP Hydro 3U is Bitmain's prior generation petahash class 3U
rack mount hydro miner, now positioned as the strongest per dollar of hashrate value play in the
3U tier as the current generation S23 Hyd 3U captures the flagship position. 860 TH/s SHA-256
hashrate at 11,180W power draw and 13 J/TH efficiency. Bitmain model number U3S21EXPH,
announced September 2024 with batch shipping from January 2025.
Positioning math matters for acquisition decisions. Compared to the current generation S23 Hyd
3U (1,160 TH/s at 11,020W and 9.5 J/TH): the S23 Hyd 3U delivers 35 percent more hashrate
and 27 percent better efficiency, but typically commands 2 to 3 times the acquisition price. For
operators with industrial electricity rates below $0.04 per kWh where electricity represents a
smaller share of total operational cost, acquisition cost savings on the S21e XP Hyd 3U
outweigh efficiency penalty over typical deployment horizons. At $0.08 per kWh commercial
rates, the efficiency gap compounds faster and the S23 Hyd 3U typically wins lifetime
economics.
Per rack economics: 14 S21e XP Hyd 3U units per 42U rack produce 12.04 PH/s at 156 kW. 14
S23 Hyd 3U units per 42U rack produce 16.24 PH/s at 154 kW. Same rack space, same power
budget, 35 percent more hashrate on the newer generation hardware. The choice depends
entirely on acquisition cost differential at your supplier pricing.
Infrastructure requirements mirror the S23 Hyd 3U. 380 to 415V three phase through LP34
industrial connector, approximately 24 amp maximum current draw. External closed loop hydro
cooling with dry cooler or heat exchanger infrastructure. 20 to 50 degrees Celsius operating
range (inlet water temperature constraints apply). 50 dB chassis noise (external cooling
infrastructure adds separate signature).
Real world profitability: OneMiners May 2025 data at $0.01 per kWh hosting: $40 to $50 daily,
averaging $44. Mining Now February 2026 at $0.07 per kWh: $30.81 daily revenue, $18.78
electricity, $12.03 daily net. ROI 12 months at $0.04 per kWh hosting per OneMiners.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Bitmain Antminer S21e XP Hydro 860 TH/s 3U Rack Mount Bitcoin Miner

Bitmain's prior generation 3U petahash class hydro Bitcoin miner at 860
TH/s, 11,180W, and 13 J/TH efficiency. Model U3S21EXPH announced September 2024,
shipping from January 2025. Now positioned as the value play in the 3U petahash tier at
significantly lower acquisition cost than the current generation S23 Hyd 3U (1.16 PH/s at 9.5
J/TH). For operators with industrial electricity below $0.04 per kWh where efficiency matters less
than acquisition cost, the S21e XP Hyd 3U delivers strong per dollar of hashrate economics.
380 to 415V three phase through LP34 industrial connector, approximately 24 amp maximum
draw. 3U rack format at 900 x 486 x 132 mm. 50 dB chassis noise. 20 to 50 degrees Celsius
operating range. Real world profitability per OneMiners May 2025 at $0.01 per kWh hosting: $40
to $50 daily, averaging $44. Mining Now February 2026 at $0.07 per kWh: $12.03 daily net. ROI
12 months at $0.04 per kWh hosting.

860 TH/s Petahash Class Value Play

Prior generation 3U rack mount at 35 percent lower hashrate than S23 Hyd 3U but typically 50 to 70 percent lower acquisition cost. Value pick for the petahash tier.

13 J/TH in 3U Rack Mount Format

Same 3U chassis format as S23 Hyd 3U. 900 x 486 x 132 mm. 14 units per 42U rack deliver 12.04 PH/s aggregate.

LP34 Three Phase Industrial Only

380 to 415V three phase through LP34 industrial connector. 24 amp maximum current draw. Strictly professional data center deployment.

Často kladené dotazy

Nejčastější otázky

860 TH/s of SHA-256 hashrate at 11,180W continuous power draw and 13 J/TH efficiency. Bitmain's ±3% hashrate tolerance means real world output ranges 834 to 886 TH/s. This is Bitmain's prior generation 3U petahash class hydro miner, positioned below the current S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) but at meaningfully lower acquisition cost reflecting the legacy inventory positioning. Official Bitmain model number U3S21EXPH.

Acquisition cost to deployment economics. The S23 Hyd 3U delivers 35 percent more hashrate and 27 percent better efficiency but typically commands 2 to 3 times the per unit acquisition cost. For operators with industrial electricity rates below $0.04 per kWh where electricity represents a smaller share of total operational cost, the S21e XP Hyd 3U acquisition savings outweigh lifetime efficiency penalty over typical 3 year deployment horizons. Scenarios favoring the S21e XP Hyd 3U: industrial hosting at $0.04 per kWh or lower, shorter deployment horizons (1 to 2 years), hardware budget constraints prioritizing unit count over per unit efficiency, fleet expansion alongside existing S21 series deployments, and speculative positioning where current BTC prices support strong margins even on less efficient hardware.

U3S21EXPH is Bitmain's official product model number for the S21e XP Hyd 3U, confirmed through ASIC Miner Value launch documentation and Kryptex Pool specifications. The "U3" prefix denotes the 3U rack mount form factor. Announced September 2024, began batch shipping from January 2025. MillionMiner's January 2024 release date listing reflects a documentation error (verified against multiple independent distributor sources).

Standardní skříň na rack 3U o rozměrech 900 x 486 x 132 mm. Kompatibilní s racky na servery o šířce 19 palců a skříněmi průmyslových těžebních zařízení. Hloubka skříně 900 mm vyžaduje minimálně 1000 mm hloubku racku pro správu kabelů, a hloubka racku 1200 mm umožňuje pohodlný přístup k kabelům a chlazení. Většina specializovaných těžebních zařízení a datových center používá racky s hloubkou 1000 mm nebo 1200 mm. Mělké racks o hloubce 600 mm nebo 750 mm nemohou toto hardware pojmout. Před závazkem k velkým objednávkám ověřte inventář racků ve zařízení.

380 to 415V three phase industrial power service through LP34 industrial connector. At 415V three phase: approximately 15 amps per phase continuous, 25 amps per phase at peak. At 380V: approximately 17 amps per phase continuous. Maximum current draw per Bitmain documentation: approximately 24 amps. Requires dedicated 32 amp three phase breakers minimum for reliable operation. LP34 industrial connector requirement excludes any single phase commercial or residential deployment. Strictly industrial hardware for professional data center and dedicated mining facility deployment.

External closed loop water cooling system with substantial thermal capacity. Each unit generates approximately 11.2 kW thermal load (38,144 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for total thermal load, inline particulate filtration, automated flow monitoring, and temperature management at inlet and outlet points. Multi unit deployments scale cooling infrastructure proportionally through manifold distribution with individual unit isolation valves for maintenance access. Budget $10,000 to $40,000 per rack for hydro cooling infrastructure depending on fleet size and existing facility capability.

Form factor and density tradeoffs against standalone alternatives. S21e XP Hyd 3U (this product): 860 TH/s at 11,180W and 13 J/TH in 3U rack format. S21 XP Hydro 473TH: 473 TH/s at 5,676W and 12 J/TH in compact standalone. S21+ Hydro 395TH: 395 TH/s at 5,925W and 15 J/TH in compact standalone. For operators wanting petahash class in 3U rack format at prior generation pricing, the S21e XP Hyd 3U wins. For operators wanting current generation efficiency at 3U format, the S23 Hyd 3U wins. For operators needing universal single phase voltage deployment, the S21 XP Hydro 473TH or S21+ Hydro 395TH single phase options are the relevant choice.

Mixed depending on electricity rate. MillionMiner $0.08 per kWh onsite calculator: $28.02 daily revenue, $21.47 electricity, $6.55 daily net profit. Mining Now February 2026 at $0.07 per kWh: $30.81 daily revenue, $18.78 electricity, $12.03 daily net. ASIC Miner Value at $0.10 per kWh: $7.26 daily profit. OneMiners May 2025 data at aggressive $0.01 per kWh hosting rates: $40 to $50 daily earnings, averaging $44. ROI estimates: 906 to 1,850 days at $0.07 per kWh per Mining Now, compressed to approximately 12 months at $0.04 per kWh industrial hosting per OneMiners.

50 dB chassis noise, effectively silent due to the absence of cooling fans. The external cooling infrastructure generates acoustic signature separately: pumps typically run 45 to 55 dB, dry coolers typically 55 to 70 dB depending on airflow requirements. Professional hydro cooled mining facilities isolate miner deployment space from cooling plant locations to minimize acoustic impact. Total deployment noise depends substantially on cooling infrastructure design and placement relative to miner deployment space.

No. The 11,180W power draw requires 380 to 415V three phase industrial electrical service with LP34 industrial power connector, unavailable in residential settings. The 11.2 kW thermal load requires substantial external water cooling infrastructure impractical for residential installation. The 900 mm chassis depth requires industrial grade rack hardware. Strictly industrial hardware for professional mining facilities and commercial data centers. For home deployment seeking hydro cooling, the Antminer S21+ Hydro 395TH with 100 to 240V universal single phase voltage represents the residential ceiling option.

Industrial deployment with three phase power, LP34 connectors, and hydro cooling infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with LP34 industrial connectors and 32 amp three phase breakers minimum. Step two: install and commission external hydro cooling loop with pumps, plumbing, coolant fill, dry cooler infrastructure, and temperature monitoring. Step three: rack mount units in 19 inch server racks verifying 1000+ mm rack depth. Connect water fittings to manifold system with individual isolation valves. Verify zero leaks before energizing. Step four: connect LP34 power cables and Ethernet management. Step five: power on, allow coolant flow to stabilize, find miner IP through DHCP, configure pool URL and Bitcoin wallet through Bitmain web interface, verify hashrate reaches 834+ TH/s within 15 to 20 minutes per unit.

Industrial hydro cooling maintenance. Weekly visual inspection of water fittings for leaks or corrosion. Monthly coolant quality testing. Every 12 to 24 months full coolant replacement. Quarterly pump and dry cooler inspection including flow rate verification. Inline filter replacement when pressure differential exceeds specification. LP34 connector inspection quarterly. Hashboard failure rates on hydro units run meaningfully lower than air cooled equivalents. As 2025 era legacy hardware, anticipate higher spare parts needs than current generation S23 equivalents. Budget 5 percent of acquisition cost annually for maintenance reserves on prior generation hardware.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

42U rack holds 14 units producing 12.04 PH/s aggregate at approximately 156 kW total power. 100 kW industrial electrical panel: approximately 8 to 9 units producing 6.88 to 7.74 PH/s aggregate. Compare alternatives at the same power budget. 100 kW of S23 Hyd 3U: 9 units producing 10.44 PH/s (35 percent more aggregate at newer generation efficiency). 100 kW of S21 XP Hydro 473TH standalone: 17 units producing 8.04 PH/s (4 percent more aggregate at universal voltage compatibility). The S21e XP Hyd 3U positions between these options on aggregate hashrate per kilowatt.

Bitmain 365 day factory warranty on the complete machine covering manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. Document coolant testing schedule and maintenance records to protect warranty coverage. MillionMiner routes warranty claims through direct Bitmain channels. As 2025 era hardware shipping from distributor inventory, verify current warranty start date with purchase batch.

Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power, LP34 industrial connectors, and hydro cooling infrastructure capable of supporting S21e XP Hyd 3U deployments. Hosted deployment eliminates facility infrastructure CapEx and leverages negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At $0.04 per kWh hosting rates, OneMiners documents approximately 12 month ROI per unit. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record. AntPool is the native Bitmain ecosystem pool. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives. For fleet deployments above 10 PH/s (equivalent to 12+ units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

CapEx beyond miner acquisition: three phase electrical service with LP34 connectors ($10,000 to $30,000 per facility), hydro cooling infrastructure ($10,000 to $40,000 per rack), industrial rack hardware ($2,000 to $5,000 per rack). Annual OpEx per unit at 11,180W continuous: electricity at $7,835 at $0.08 per kWh, $6,855 at $0.07 per kWh, $3,917 at $0.04 per kWh industrial hosting rates. Water glycol coolant maintenance and spare parts reserves. 3 year TCO per unit at $0.07 per kWh self hosted: approximately $11,649 hardware plus $20,565 electricity plus $2,000 maintenance equals $34,214 total. 3 year gross revenue at $0.07 per kWh profitability: approximately $13,200 to $17,600 depending on BTC price scenarios.

Run the math with supplier specific pricing. Illustrative scenario: if S23 Hyd 3U costs $30,000 and S21e XP Hyd 3U costs $12,000 per unit, the $18,000 price differential on the newer hardware must be recovered through efficiency savings. At 1,160 TH/s versus 860 TH/s (300 TH/s more on newer hardware) and 9.5 J/TH versus 13 J/TH efficiency gap, per year electricity savings on the newer hardware run approximately $2,600 at $0.07 per kWh. The $18,000 price differential would take 7 years to recover through pure efficiency, but the newer hardware also delivers higher revenue through 35 percent more hashrate. Factoring both efficiency savings and additional revenue, price differential recovers in approximately 18 to 30 months depending on BTC price scenarios. At deployment horizons beyond 2 years with current BTC price levels, S23 Hyd 3U typically wins. Below 18 months or at deeply discounted S21e XP pricing, the value play works.

V rámci generace Bitmain S23 (novější, vyšší účinnost): S23 Hyd 3U s 1,16 PH/s pro špičkový petahash, S23 Hydro 580TH samostatně pro jednotlivé kompaktní nasazení, S23 Air 318TH pro vzduchem chlazené, S23 Immersion 442TH pro tankové nasazení. V rámci generace Bitmain S21 (stejné období, univerzální napětí): S21 XP Hydro 473TH pro samostatné jednofázové nasazení, S21+ Hydro 395TH pro nasazení s univerzálním napětím bez třífázové sítě, S21e XP Hyd 430TH pro nižší třídou 3U alternativu. Pro operátory diverzifikující napříč výrobci na úrovni petahash hydro: Whatsminer M79S 1,35 PH/s představuje ekvivalent vysokého výkonu hydro úrovně MicroBT, Whatsminer M73S+ 540TH nabízí nižší úroveň hydro rack mount. Diverzifikace flotily přes různé algoritmy: Antminer KS7 pro Kaspa, Antminer L11 pro Litecoin a Dogecoin sloučené těžby, IceRiver AE3 pro Aleo, Antminer Z15 pro Zcash. Pro operace budující modulární infrastrukturu s dlouhou životností: Proto Rig s 819 TH/s nabízí alternativu moduly s rámem na více než 10 let od společnosti Block. Služba hostování ASIC od MillionMiner přijímá jednotky S21e XP Hyd 3U za smluvně dohodnuté průmyslové ceny elektřiny.

Get a Quote