Bitmain's prior generation 3U petahash class hydro cooled Bitcoin miner, delivering 860 TH/s SHA-256 hashrate at 11,180W power draw and 13 J/TH efficiency. Model U3S21EXPH announced September 2024 with shipping from January 2025. Positioned directly below the current generation S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) at significantly lower acquisition cost, making the S21e XP Hyd 3U the strongest per dollar of hashrate value play in the 3U petahash tier. 380 to 415V three phase industrial power with approximately 24 amp maximum current draw. 3U rack mount format in 900 x 486 x 132 mm chassis at approximately 50 kg deployed weight. 50 dB chassis noise (external cooling infrastructure separate). 20 to 50 degrees Celsius operating range. External closed loop hydro cooling with dry cooler or heat exchanger infrastructure rated for 11.2 kW thermal load per unit. ±3% hashrate tolerance means real output 834 to 886 TH/s. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.
Vyberte dostupnost
Množství
$11,649.00
Buying 10 or more? Get custom bulk pricing
Opravdový
Otestovaný hardware
Celosvětově
Celosvětová doprava
Podpora
Odborníci na těžbu
Těžební výkon
860 TH/s
Výkon
11180 W
Účinnost
13.00 J/TH
Hluk
50 dB
Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.
| Období | Denně | Týdenní | Měsíční |
|---|---|---|---|
|
Příjmy
|
$33.36 | $233.52 | $1,000.80 |
|
Elektrická energie
|
-$13.42 | -$93.94 | -$402.60 |
|
Zisk
|
$19.94 | $139.58 | $598.20 |
Using 0.050 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.
Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.
Connect PSU to miner and plug into the outlet
Připojte ethernetový kabel k vašemu routeru nebo switchi
Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP
Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit
Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.
Prior generation 3U rack mount at 35 percent lower hashrate than S23 Hyd 3U but typically 50 to 70 percent lower acquisition cost. Value pick for the petahash tier.
Same 3U chassis format as S23 Hyd 3U. 900 x 486 x 132 mm. 14 units per 42U rack deliver 12.04 PH/s aggregate.
380 to 415V three phase through LP34 industrial connector. 24 amp maximum current draw. Strictly professional data center deployment.
860 TH/s of SHA-256 hashrate at 11,180W continuous power draw and 13 J/TH efficiency. Bitmain's ±3% hashrate tolerance means real world output ranges 834 to 886 TH/s. This is Bitmain's prior generation 3U petahash class hydro miner, positioned below the current S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) but at meaningfully lower acquisition cost reflecting the legacy inventory positioning. Official Bitmain model number U3S21EXPH.
Acquisition cost to deployment economics. The S23 Hyd 3U delivers 35 percent more hashrate and 27 percent better efficiency but typically commands 2 to 3 times the per unit acquisition cost. For operators with industrial electricity rates below $0.04 per kWh where electricity represents a smaller share of total operational cost, the S21e XP Hyd 3U acquisition savings outweigh lifetime efficiency penalty over typical 3 year deployment horizons. Scenarios favoring the S21e XP Hyd 3U: industrial hosting at $0.04 per kWh or lower, shorter deployment horizons (1 to 2 years), hardware budget constraints prioritizing unit count over per unit efficiency, fleet expansion alongside existing S21 series deployments, and speculative positioning where current BTC prices support strong margins even on less efficient hardware.
U3S21EXPH is Bitmain's official product model number for the S21e XP Hyd 3U, confirmed through ASIC Miner Value launch documentation and Kryptex Pool specifications. The "U3" prefix denotes the 3U rack mount form factor. Announced September 2024, began batch shipping from January 2025. MillionMiner's January 2024 release date listing reflects a documentation error (verified against multiple independent distributor sources).
Standardní skříň na rack 3U o rozměrech 900 x 486 x 132 mm. Kompatibilní s racky na servery o šířce 19 palců a skříněmi průmyslových těžebních zařízení. Hloubka skříně 900 mm vyžaduje minimálně 1000 mm hloubku racku pro správu kabelů, a hloubka racku 1200 mm umožňuje pohodlný přístup k kabelům a chlazení. Většina specializovaných těžebních zařízení a datových center používá racky s hloubkou 1000 mm nebo 1200 mm. Mělké racks o hloubce 600 mm nebo 750 mm nemohou toto hardware pojmout. Před závazkem k velkým objednávkám ověřte inventář racků ve zařízení.
380 to 415V three phase industrial power service through LP34 industrial connector. At 415V three phase: approximately 15 amps per phase continuous, 25 amps per phase at peak. At 380V: approximately 17 amps per phase continuous. Maximum current draw per Bitmain documentation: approximately 24 amps. Requires dedicated 32 amp three phase breakers minimum for reliable operation. LP34 industrial connector requirement excludes any single phase commercial or residential deployment. Strictly industrial hardware for professional data center and dedicated mining facility deployment.
External closed loop water cooling system with substantial thermal capacity. Each unit generates approximately 11.2 kW thermal load (38,144 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for total thermal load, inline particulate filtration, automated flow monitoring, and temperature management at inlet and outlet points. Multi unit deployments scale cooling infrastructure proportionally through manifold distribution with individual unit isolation valves for maintenance access. Budget $10,000 to $40,000 per rack for hydro cooling infrastructure depending on fleet size and existing facility capability.
Form factor and density tradeoffs against standalone alternatives. S21e XP Hyd 3U (this product): 860 TH/s at 11,180W and 13 J/TH in 3U rack format. S21 XP Hydro 473TH: 473 TH/s at 5,676W and 12 J/TH in compact standalone. S21+ Hydro 395TH: 395 TH/s at 5,925W and 15 J/TH in compact standalone. For operators wanting petahash class in 3U rack format at prior generation pricing, the S21e XP Hyd 3U wins. For operators wanting current generation efficiency at 3U format, the S23 Hyd 3U wins. For operators needing universal single phase voltage deployment, the S21 XP Hydro 473TH or S21+ Hydro 395TH single phase options are the relevant choice.
Mixed depending on electricity rate. MillionMiner $0.08 per kWh onsite calculator: $28.02 daily revenue, $21.47 electricity, $6.55 daily net profit. Mining Now February 2026 at $0.07 per kWh: $30.81 daily revenue, $18.78 electricity, $12.03 daily net. ASIC Miner Value at $0.10 per kWh: $7.26 daily profit. OneMiners May 2025 data at aggressive $0.01 per kWh hosting rates: $40 to $50 daily earnings, averaging $44. ROI estimates: 906 to 1,850 days at $0.07 per kWh per Mining Now, compressed to approximately 12 months at $0.04 per kWh industrial hosting per OneMiners.
50 dB chassis noise, effectively silent due to the absence of cooling fans. The external cooling infrastructure generates acoustic signature separately: pumps typically run 45 to 55 dB, dry coolers typically 55 to 70 dB depending on airflow requirements. Professional hydro cooled mining facilities isolate miner deployment space from cooling plant locations to minimize acoustic impact. Total deployment noise depends substantially on cooling infrastructure design and placement relative to miner deployment space.
No. The 11,180W power draw requires 380 to 415V three phase industrial electrical service with LP34 industrial power connector, unavailable in residential settings. The 11.2 kW thermal load requires substantial external water cooling infrastructure impractical for residential installation. The 900 mm chassis depth requires industrial grade rack hardware. Strictly industrial hardware for professional mining facilities and commercial data centers. For home deployment seeking hydro cooling, the Antminer S21+ Hydro 395TH with 100 to 240V universal single phase voltage represents the residential ceiling option.
Industrial deployment with three phase power, LP34 connectors, and hydro cooling infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with LP34 industrial connectors and 32 amp three phase breakers minimum. Step two: install and commission external hydro cooling loop with pumps, plumbing, coolant fill, dry cooler infrastructure, and temperature monitoring. Step three: rack mount units in 19 inch server racks verifying 1000+ mm rack depth. Connect water fittings to manifold system with individual isolation valves. Verify zero leaks before energizing. Step four: connect LP34 power cables and Ethernet management. Step five: power on, allow coolant flow to stabilize, find miner IP through DHCP, configure pool URL and Bitcoin wallet through Bitmain web interface, verify hashrate reaches 834+ TH/s within 15 to 20 minutes per unit.
Industrial hydro cooling maintenance. Weekly visual inspection of water fittings for leaks or corrosion. Monthly coolant quality testing. Every 12 to 24 months full coolant replacement. Quarterly pump and dry cooler inspection including flow rate verification. Inline filter replacement when pressure differential exceeds specification. LP34 connector inspection quarterly. Hashboard failure rates on hydro units run meaningfully lower than air cooled equivalents. As 2025 era legacy hardware, anticipate higher spare parts needs than current generation S23 equivalents. Budget 5 percent of acquisition cost annually for maintenance reserves on prior generation hardware.
Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.
42U rack holds 14 units producing 12.04 PH/s aggregate at approximately 156 kW total power. 100 kW industrial electrical panel: approximately 8 to 9 units producing 6.88 to 7.74 PH/s aggregate. Compare alternatives at the same power budget. 100 kW of S23 Hyd 3U: 9 units producing 10.44 PH/s (35 percent more aggregate at newer generation efficiency). 100 kW of S21 XP Hydro 473TH standalone: 17 units producing 8.04 PH/s (4 percent more aggregate at universal voltage compatibility). The S21e XP Hyd 3U positions between these options on aggregate hashrate per kilowatt.
Bitmain 365 day factory warranty on the complete machine covering manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. Document coolant testing schedule and maintenance records to protect warranty coverage. MillionMiner routes warranty claims through direct Bitmain channels. As 2025 era hardware shipping from distributor inventory, verify current warranty start date with purchase batch.
Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power, LP34 industrial connectors, and hydro cooling infrastructure capable of supporting S21e XP Hyd 3U deployments. Hosted deployment eliminates facility infrastructure CapEx and leverages negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At $0.04 per kWh hosting rates, OneMiners documents approximately 12 month ROI per unit. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.
Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record. AntPool is the native Bitmain ecosystem pool. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives. For fleet deployments above 10 PH/s (equivalent to 12+ units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.
CapEx beyond miner acquisition: three phase electrical service with LP34 connectors ($10,000 to $30,000 per facility), hydro cooling infrastructure ($10,000 to $40,000 per rack), industrial rack hardware ($2,000 to $5,000 per rack). Annual OpEx per unit at 11,180W continuous: electricity at $7,835 at $0.08 per kWh, $6,855 at $0.07 per kWh, $3,917 at $0.04 per kWh industrial hosting rates. Water glycol coolant maintenance and spare parts reserves. 3 year TCO per unit at $0.07 per kWh self hosted: approximately $11,649 hardware plus $20,565 electricity plus $2,000 maintenance equals $34,214 total. 3 year gross revenue at $0.07 per kWh profitability: approximately $13,200 to $17,600 depending on BTC price scenarios.
Run the math with supplier specific pricing. Illustrative scenario: if S23 Hyd 3U costs $30,000 and S21e XP Hyd 3U costs $12,000 per unit, the $18,000 price differential on the newer hardware must be recovered through efficiency savings. At 1,160 TH/s versus 860 TH/s (300 TH/s more on newer hardware) and 9.5 J/TH versus 13 J/TH efficiency gap, per year electricity savings on the newer hardware run approximately $2,600 at $0.07 per kWh. The $18,000 price differential would take 7 years to recover through pure efficiency, but the newer hardware also delivers higher revenue through 35 percent more hashrate. Factoring both efficiency savings and additional revenue, price differential recovers in approximately 18 to 30 months depending on BTC price scenarios. At deployment horizons beyond 2 years with current BTC price levels, S23 Hyd 3U typically wins. Below 18 months or at deeply discounted S21e XP pricing, the value play works.
V rámci generace Bitmain S23 (novější, vyšší účinnost): S23 Hyd 3U s 1,16 PH/s pro špičkový petahash, S23 Hydro 580TH samostatně pro jednotlivé kompaktní nasazení, S23 Air 318TH pro vzduchem chlazené, S23 Immersion 442TH pro tankové nasazení. V rámci generace Bitmain S21 (stejné období, univerzální napětí): S21 XP Hydro 473TH pro samostatné jednofázové nasazení, S21+ Hydro 395TH pro nasazení s univerzálním napětím bez třífázové sítě, S21e XP Hyd 430TH pro nižší třídou 3U alternativu. Pro operátory diverzifikující napříč výrobci na úrovni petahash hydro: Whatsminer M79S 1,35 PH/s představuje ekvivalent vysokého výkonu hydro úrovně MicroBT, Whatsminer M73S+ 540TH nabízí nižší úroveň hydro rack mount. Diverzifikace flotily přes různé algoritmy: Antminer KS7 pro Kaspa, Antminer L11 pro Litecoin a Dogecoin sloučené těžby, IceRiver AE3 pro Aleo, Antminer Z15 pro Zcash. Pro operace budující modulární infrastrukturu s dlouhou životností: Proto Rig s 819 TH/s nabízí alternativu moduly s rámem na více než 10 let od společnosti Block. Služba hostování ASIC od MillionMiner přijímá jednotky S21e XP Hyd 3U za smluvně dohodnuté průmyslové ceny elektřiny.