Skladem

Bitmain

Bitmain Antminer S23 Immersion (442TH)

Model: Antminer S23 Immersion

Nový

Bitmain's immersion cooled S23 generation Bitcoin miner designed for tank deployment in dielectric fluid. 442 TH/s SHA-256 hashrate at 5,304W power draw and 12 J/TH efficiency. Completely fanless chassis with zero mechanical components once submerged. Announced June 2025 with batch shipping beginning January 2026. 368 to 442 TH/s tuned hashrate range at 4,048 to 5,304W power profile. ±5% hashrate tolerance and ±10% power tolerance (wider than typical S23 air and hydro variants). 293 x 236 x 364 mm chassis at 17.1 kg dry weight before fluid displacement. 380 to 415V three phase industrial power required. 30 to 55 degrees Celsius operating temperature range (elevated minimum reflects immersion fluid steady state operation). Compatible dielectric fluids include Shell Diala, ElectroCool, and Novec. Heat reuse applications span building heating, greenhouses, and industrial process integration. 90 percent cooling energy savings versus air cooled equivalents per MillionMiner documentation. 50 percent extended hardware lifespan through zero dust ingress and consistent chip temperature. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.

442 TH/s 5304W SHA-256 12 J/TH

Vyberte dostupnost

Množství

Celková cena

$11,096.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bankovní převod | BTC | ETH | USDT

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

442 TH/s

Výkon

5304 W

Účinnost

12.00 J/TH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$16.53 $115.71 $495.90
Elektrická energie
-$10.18 -$71.26 -$305.40
Zisk
$6.35 $44.45 $190.50

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 442 TH/s
Spotřeba energie 5304 W
Účinnost 12.00 J/TH
Algoritmus SHA-256
Model Antminer S23 Immersion
Rok vydání Červen 2025
Hladina hluku 50 dB
Rozměry 364 x 236 x 293mm
Váha 17.1 kg
Napětí 380-415V
Rozhraní Ethernet
Provozní teplota 30 - 55 °C
vlhkost 10 - 90 %
Typ chlazení Immersion

Co je v krabici

Antminer S23 Immersion
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Detaily produktu

Bitmain Antminer S23 Immersion 442 TH/s Fanless Dielectric Fluid Tank Deployment Bitcoin Miner: Complete Specifications, Immersion Deployment Guide, and Heat Reuse Economics

The Bitmain Antminer S23 Immersion is the tank deployment variant of the S23 generation, purpose built for operation fully submerged in dielectric cooling fluid rather than air or hydro cooling. 442 TH/s SHA-256 hashrate at 5,304W continuous power draw and 12 J/TH efficiency. Bitmain announced the S23 Immersion alongside the S23 Hydro, S23 Air, and S23 Hyd 3U variants in June 2025, with batch shipping beginning January 2026 per OneMiners distribution documentation. Multiple batch windows documented through Q1 and Q2 2026 (January, February, March 2026 batches confirmed by OneMiners). Tuning profiles support 368 to 442 TH/s hashrate range at 4,048 to 5,304W power envelope, with ±5% hashrate tolerance and ±10% power tolerance (wider than the ±3% hashrate and ±5% power typical of S23 air and hydro variants). The wider tolerance reflects immersion fluid thermal performance variability across deployment configurations and fluid selections. Positioning within the S23 generation lineup quantifies the tradeoff. S23 Hydro 580TH: 9.5 J/TH at 5,510W in compact standalone hydro format. S23 Hyd 3U 1.16 PH/s: 9.5 J/TH at 11,020W in 3U petahash flagship format. S23 Air 318TH: 11 J/TH at 3,498W with cooling fans. S23 Immersion 442TH (this product): 12 J/TH at 5,304W in dielectric fluid tank. The Immersion variant does not win on efficiency within the S23 generation (the Hydro variants deliver 26 percent better efficiency at 9.5 versus 12 J/TH). The Immersion wins on deployment characteristics: fanless operation, extended hardware lifespan, simplified maintenance, and heat reuse capability. Immersion cooling architecture delivers measurable operational benefits distinct from air or hydro approaches. Zero fans means no fan replacements, no fan failure incidents, no airflow obstruction maintenance, no vibration related component stress over extended runtime. Fluid thermal mass dampens temperature variation meaningfully: where air cooled chip temperatures can fluctuate 10 to 20 degrees Celsius with varying ambient conditions and load profiles, immersion fluid thermal capacity holds chips within 2 to 5 degree Celsius variation. Dust elimination is complete because the hardware operates in sealed fluid rather than open air. These combined factors extend hardware lifespan up to 50 percent versus equivalent air cooled hardware per MillionMiner documentation, meaningful in amortizing the acquisition cost over longer deployment horizons. Cooling energy economics favor immersion in aggregate. MillionMiner documents 90 percent cooling energy savings versus air cooled equivalents. The math: air cooled data center facilities typically use 30 to 50 percent of total electrical load for HVAC cooling of miner heat. Immersion eliminates the in-chassis fan electricity and dramatically reduces facility HVAC load because heat transfers directly to dielectric fluid and external dry coolers rather than through air intermediary. For a 1 MW facility, aggregate annual cooling electricity savings typically reach $50,000 to $150,000 at industrial electricity rates. Physical specifications: 293 x 236 x 364 mm chassis at 17.1 kg dry weight before fluid displacement. Plan tank capacity and structural loading to account for combined weight of hardware plus dielectric fluid. Single phase immersion tank configurations typically hold 4 to 12 miners depending on tank size and fluid capacity. Two phase immersion tanks (where fluid actively boils at chip contact points) offer higher heat transfer efficiency but require more sophisticated fluid management and higher initial capital investment. Compatible dielectric fluids span three primary categories documented by MillionMiner. Shell Diala: mineral oil based, lowest acquisition cost, widely available, moderate thermal conductivity, environmentally benign. ElectroCool: engineered synthetic fluid, higher thermal conductivity, better long term chemical stability, higher acquisition cost. 3M Novec: fluorinated engineered fluid, exceptional thermal performance and fire safety characteristics, highest acquisition cost, environmental concerns with PFAS class compounds. Fluid selection balances capital cost, operational characteristics, long term availability, and environmental considerations. Power infrastructure: 380 to 415V three phase industrial power service. At 415V three phase: approximately 7.4 amps per phase continuous at 5,304W. At 380V: approximately 8 amps per phase continuous. Fits standard 16 amp three phase breakers with meaningful headroom. Strictly industrial hardware for professional data center and dedicated mining facility deployment with immersion infrastructure. Operating temperature range 30 to 55 degrees Celsius reflects the elevated steady state temperature of immersion fluid operation. Minimum 30 degrees versus 20 degrees on S23 Hydro and 5 degrees on S23 Hyd 3U reflects the fluid thermal mass and steady state operating conditions rather than ambient air temperature. Maximum 55 degrees exceeds other S23 variants (Hydro 50 degrees, Hyd 3U 45 degrees), reflecting the superior heat transfer capability of fluid submersion versus air or hydro cooling approaches. Heat reuse applications transform immersion mining heat from disposal cost into secondary revenue. Captured heat at 40 to 55 degrees Celsius fluid temperature supports multiple applications: building heating through water to water heat exchangers integrated with hydronic heating systems, greenhouse climate control in agricultural operations, district heating integration in urban deployments, industrial process preheating in manufacturing facilities, and aquaculture water temperature management. Multiple European mining operations (Norway, Sweden, Germany, Netherlands) monetize waste heat through greenhouse partnerships and residential heating contracts, converting mining heat from disposal cost to revenue stream worth $500 to $2,000 annually per miner in favorable configurations. Ships with PSU, 365 day Bitmain factory warranty (per BT-Miners documentation), and free DDP worldwide delivery from MillionMiner including customs clearance.

Bitmain Antminer S23 Immersion 442 TH/s: The Fanless S23 Variant for Tank

The S23 Immersion is Bitmain's tank deployment variant of the S23
generation, purpose built for submerged operation in dielectric fluid. 442 TH/s SHA-256
hashrate at 5,304W power draw and 12 J/TH efficiency. Completely fanless chassis with zero
mechanical components once submerged. Announced June 2025 with batch shipping beginning
January 2026 (multi batch rollout documented at OneMiners across Q1 and Q2 2026).
Positioning within S23 generation: S23 Hydro 580TH (9.5 J/TH, standalone hydro with external
water loop), S23 Hyd 3U 1.16 PH/s (9.5 J/TH, flagship 3U petahash), S23 Air 318TH (11 J/TH,
air cooled fans), S23 Immersion 442TH (this product, 12 J/TH, tank submerged). The S23
Immersion trades raw efficiency for fanless simplicity, extended hardware lifespan, and heat
reuse capability. Does not compete on efficiency with the S23 Hydro variants. Competes on
deployment model and operational characteristics.
Immersion cooling delivers measurable benefits. Zero fans means no fan failures, no dust
buildup on heatsinks, no vibration related component stress over extended runtime. Dielectric
fluid thermal mass dampens temperature variation, keeping chip temperatures consistent and
predictable. MillionMiner documents 90 percent cooling energy savings versus air cooled
equivalents through elimination of facility HVAC load for miner cooling. Hardware lifespan
extends up to 50 percent through consistent thermal environment and dust elimination.
Heat reuse opens secondary revenue opportunities. Captured waste heat at 40 to 55 degrees
Celsius supports building heating, greenhouse climate control, district heating integration,
industrial process preheating, and agricultural applications. Multiple European mining operations
monetize waste heat through greenhouse partnerships and residential heating contracts,
converting mining heat from disposal cost to revenue stream.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Bitmain Antminer S23 Immersion 442 TH/s Fanless Dielectric Fluid Bitcoin Miner

Bitmain's immersion cooled S23 generation Bitcoin miner for dielectric fluid
tank deployment. 442 TH/s SHA-256 hashrate at 5,304W and 12 J/TH efficiency. Completely
fanless chassis with zero mechanical components once submerged. Announced June 2025,
batch shipping from January 2026. 293 x 236 x 364 mm chassis at 17.1 kg dry weight. 380 to
415V three phase industrial power. 30 to 55 degrees Celsius operating range. Compatible with
Shell Diala, ElectroCool, and Novec dielectric fluids. 90 percent cooling energy savings versus
air cooled equivalents. 50 percent extended hardware lifespan through zero dust ingress and
consistent chip temperature. Heat reuse applications include building heating, greenhouses,
and industrial process integration. Real world profitability per OneMiners April to August 2025 at
$0.04 per kWh hosting: $14 to $20 daily, averaging $16.82, with 8 to 14 month ROI. MillionMiner
$0.08 per kWh: $4.20 daily net. Ships with 365 day Bitmain warranty and free DDP worldwide.

Zero Fans, Zero Dust, Zero Moving Parts

Zcela ponořené v dielektrickém kapalném médiu. Životnost hardwaru prodloužená o 50 procent díky konstantní teplotě čipu a úplnému odstranění prachu.

442 TH/s at 12 J/TH in Tank Deployment

Účinnost generace S23 v ponorném režimu. Rozsah ladění 368 až 442 TH/s při spotřebě 4 048 až 5 304 W v závislosti na konfiguraci kapaliny.

90 Percent Cooling Energy Savings

Direct fluid heat capture eliminates facility HVAC load. Heat reuse for building heating, greenhouses, and industrial processes.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

442 TH/s of SHA-256 hashrate at 5,304W continuous power draw and 12 J/TH efficiency. Bitmain's immersion variant supports wider tuning profiles than air or hydro variants: hashrate range 368 to 442 TH/s at 4,048 to 5,304W power envelope with ±5% hashrate tolerance and ±10% power tolerance (broader than the ±3% hashrate and ±5% power of other S23 variants). The wider tolerance reflects immersion fluid thermal performance variability across deployment configurations and fluid selections.

Immersion cooling submerges the entire miner in a non-conductive dielectric fluid that absorbs heat directly from all components simultaneously. No fans are needed, no air circulation, no dust ingress, no fan maintenance. Air cooling uses fans to move heat from components to surrounding air, requiring HVAC facility cooling of that heated air. Hydro cooling uses sealed water channels inside the chassis to transfer heat to an external water loop, keeping the chassis itself air neutral but requiring plumbing infrastructure. Immersion eliminates both air and sealed water approaches by submerging the hardware directly in thermal transfer fluid. Each approach has deployment tradeoffs: air is simplest and lowest CapEx, hydro delivers best compact efficiency, immersion delivers best longevity and heat reuse but highest CapEx for tank infrastructure.

Yes, completely fanless once submerged in dielectric fluid. The chassis ships without internal cooling fans because fluid submersion provides direct heat transfer from all components. No fan failures, no fan noise, no fan replacement costs, no fan related airflow obstruction, no fan vibration stress on components. The miner sits silent inside the immersion tank. External cooling infrastructure (circulation pumps, dry cooler or heat exchanger) adds its own acoustic signature separate from the miner itself.

Yes, meaningfully. MillionMiner documentation references up to 50 percent extended hardware lifespan through zero dust ingress and consistent chip temperature. The physics: air cooled chip temperatures typically fluctuate 10 to 20 degrees Celsius with varying ambient conditions and load profiles, creating thermal expansion and contraction stress on chip packaging, solder joints, and internal bonds. Immersion fluid thermal mass holds chips within 2 to 5 degree Celsius variation, dramatically reducing thermal cycling stress. Dust elimination removes another wear mechanism entirely (dust contamination is a leading cause of heatsink and fan failures in air cooled deployments). Combined, these factors extend practical deployment lifespan from typical 3 to 4 years on air cooled hardware to 5 to 7 years on immersion.

Významné kapitálové výdaje nad rámec nákupu těžaře. Infrastruktura immersion tanku: jednopolohový tank ($2 000 až $10 000 za tank v závislosti na velikosti a kvalitě), dvoupolohový tank ($15 000 až $50 000 za tank pro špičkové nasazení). Dielektrická kapalina: Shell Diala ($2 až $4 za litr při velkoobjemu), ElectroCool ($15 až $30 za litr), Novec ($50 až $200 za litr). Jednopolohový tank obsahující 8 těžařů obvykle vyžaduje 200 až 400 litrů kapaliny. Čerpadla cirkulace ($1 500 až $5 000 za tank). Suchý chladič nebo vodní výměník tepla pro dielektrikum ($5 000 až $25 000 za stojan v závislosti na kapacitě). Systémy monitorování a správy kapaliny ($1 000 až $10 000 za nasazení). Instalace elektrického rozvodu třífázového napětí 380 až 415V ($5 000 až $20 000 za zařízení). Celkové kapitálové výdaje na těžaře pro zelené pole immersion nasazení: obvykle $4 000 až $12 000 nad náklady na pořízení těžaře.

Podle dokumentace Per MillionMiner jsou tři hlavní kompatibilní kategorie kapalin. Shell Diala: minerální olivová na bázi, nejnižší pořizovací náklady (obvykle 2 až 4 dolarů za litr ve velkém měřítku), široká dostupnost po celém světě, střední tepelná vodivost, šetrné k životnímu prostředí, biologicky rozložitelné. ElectroCool: syntetická kapalinová směs na míru navržená, vyšší tepelná vodivost než minerální olej, lepší dlouhodobá chemická stabilita, střední pořizovací náklady (15 až 30 dolarů za litr), speciálně nabízená pro ponorné aplikace v datových centrech. 3M Novec (skupina fluorovaných syntetických kapalin): vynikající tepelný výkon a vlastnosti z hlediska požární bezpečnosti, nejvyšší pořizovací náklady (50 až 200 dolarů za litr), environmentální obavy spojené s látkami třídy PFAS, regulační nejistota v EU a v několika státech USA. Výběr kapaliny vyvažuje kapitálové náklady, provozní charakteristiky, dlouhodobou dostupnost zásob a environmentální aspekty.

Yes, productively. Captured heat at 40 to 55 degrees Celsius dielectric fluid temperature supports multiple applications. Building heating through water to water heat exchangers integrated with hydronic heating systems (radiators, in floor heating, forced air furnace preheating). Greenhouse climate control in agricultural operations. District heating integration in urban deployments where municipal heating infrastructure exists. Industrial process preheating in manufacturing facilities (water preheating, washing systems, drying operations). Aquaculture water temperature management. Multiple European mining operations (Norway, Sweden, Germany, Netherlands) monetize waste heat through greenhouse partnerships and residential heating contracts, converting mining heat from disposal cost to revenue stream worth $500 to $2,000 annually per miner in favorable configurations. Heat reuse transforms miner TCO economics meaningfully in geographically appropriate deployments.

Sensitive to electricity rate and heat reuse capture. MillionMiner $0.08 per kWh onsite calculator: $14.38 daily revenue, $10.18 electricity, $4.20 daily net profit. Mining Now February 2026 at $0.07 per kWh: $15.84 daily revenue, $8.91 electricity, $7.92 daily net. ASIC Miner Value at $0.00 per kWh reference (free electricity): $10.24 daily profit (showing gross revenue baseline). OneMiners April to August 2025 data at $0.04 per kWh industrial hosting: $14 to $20 daily earnings, averaging $16.82. ROI estimates 1,210 to 1,515 days at $0.07 per kWh per Mining Now, compressed to 8 to 14 months at $0.04 per kWh industrial hosting per OneMiners. Heat reuse capture adds $500 to $2,000 annual value per miner in favorable configurations, meaningfully improving lifetime economics above pure mining revenue.

No. The 380 to 415V three phase power requirement excludes residential electrical service in most regions. The immersion tank infrastructure, dielectric fluid capacity, and external cooling systems are impractical for residential installation. The fluid fire safety and environmental management requirements require industrial facility infrastructure. This is strictly industrial hardware for professional mining facilities and commercial data centers with immersion infrastructure. For home deployment, the Antminer S21+ Hydro 395TH with universal 100 to 240V single phase voltage represents the residential hydro ceiling, or the Antminer S21 XP 270TH air cooled for standard single phase residential mining.

Different cooling approaches with distinct deployment tradeoffs. S23 Immersion 442TH (this product): 442 TH/s at 5,304W and 12 J/TH, tank submerged in dielectric fluid, zero fans, 50 percent extended lifespan, heat reuse capable, requires immersion tank infrastructure. S23 Hydro 580TH: 580 TH/s at 5,510W and 9.5 J/TH, standalone chassis with sealed internal water channels, requires external hydro loop with dry cooler, 26 percent better efficiency at 32 percent more hashrate per unit. The S23 Hydro wins decisively on efficiency and raw hashrate per unit. The S23 Immersion wins on hardware lifespan, maintenance simplification, heat reuse economics, and deployment model for facilities already committed to immersion infrastructure. For greenfield deployments, the S23 Hydro typically delivers better 3 to 5 year economics through efficiency alone. For operators with immersion infrastructure or quantifiable heat reuse value, the S23 Immersion delivers better 7+ year economics through extended lifespan and secondary revenue.

Same generation, different cooling and performance tiers. S23 Immersion 442TH (this product): 442 TH/s at 5,304W and 12 J/TH, fanless tank deployment. S23 Air 318TH: 318 TH/s at 3,498W and 11 J/TH, air cooled with fans. The S23 Immersion delivers 39 percent more hashrate per unit with 9 percent worse per chip efficiency. The S23 Air delivers lower acquisition cost, simpler deployment (standard air cooled rack), and lower infrastructure CapEx. The S23 Immersion delivers zero fan noise, zero dust maintenance, extended hardware lifespan, and heat reuse capability. For small to medium deployments without existing immersion infrastructure, the S23 Air typically wins on total deployment cost. For large deployments where immersion CapEx amortizes across many units, the S23 Immersion wins on operational economics.

380 to 415V three phase industrial power service. At 415V three phase: approximately 7.4 amps per phase continuous at 5,304W draw. At 380V three phase: approximately 8 amps per phase continuous. Fits standard 16 amp three phase breakers with meaningful headroom. Power infrastructure requirements are less demanding than the 3U petahash class hardware (S23 Hyd 3U at 11,020W) but still require industrial three phase service unavailable in residential configurations. Strictly industrial hardware for professional data center and dedicated mining facility deployment.

Industrial deployment with three phase power and immersion tank infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with appropriate breaker capacity. Step two: install immersion tank with dielectric fluid (Shell Diala, ElectroCool, or Novec) and external cooling loop with dry cooler or water to dielectric heat exchanger. Step three: mount the S23 Immersion units in tank racking infrastructure with appropriate fluid gaps for convective circulation. Step four: fill tank with dielectric fluid to specified level, verify proper immersion depth for all components. Step five: connect three phase power cables and Ethernet management through sealed fluid penetrations. Step six: power on, find miner IP through DHCP, open Bitmain web interface, configure pool URL and Bitcoin wallet, verify hashrate reaches 420+ TH/s (or tuning target) within 15 to 20 minutes per unit. Step seven: configure heat reuse loop integration if applicable to deployment.

Podstatně sníženo ve srovnání s vodouchlazenými ekvivalenty díky bezfanovému provozu a eliminaci prachu. Čtvrtletné testování kvality dielektrického média (kyselost, vlhkost, úrovně pevných částic). Polročná vizuální kontrola armatur nádrže a elektrických průchodů na úniky nebo korozi. Roční kontrola cirkulačního čerpadla a suché chladicí jednotky. Výměna kapaliny každé 3 až 5 let v závislosti na chemii kapaliny a podmínkách používání (ve srovnání s 12 až 24 měsíci u hydro systému). Míra selhání hashboardu u ponořených jednotek je výrazně nižší než u vodouchlazených ekvivalentů díky stálým teplotám čipů a nulové kontaminaci prachem. Nula údržby ventilátorů, nulové čištění prachu, nulové nastavování proudění vzduchu. Rozpočet 2 až 3 procenta z pořizovací ceny ročně na rezervy na údržbu (nižší než u hydro nebo vodouchlazených ekvivalentů).

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

365 day Bitmain factory warranty per BT-Miners documentation on new units. MillionMiner's extended product description references 6 month manufacturer warranty, reflecting potential warranty term variation across batches or distributor channels. OneMiners references extended warranty to 7 years for hosted deployments. Warranty exclusions include damage from dielectric fluid contamination or neglect, improper fluid selection outside compatible list, leaks in tank infrastructure, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. Document fluid testing schedule and maintenance records to protect warranty coverage. Verify current warranty terms with MillionMiner at time of purchase.

Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power and immersion cooling infrastructure capable of supporting S23 Immersion deployments. Hosted deployment eliminates facility infrastructure CapEx (three phase electrical service, immersion tank installation, dielectric fluid acquisition, external cooling infrastructure) and leverages negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At $0.04 per kWh hosting rates, OneMiners documents $14 to $20 daily earnings per unit during April to August 2025 operational data. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record. AntPool is the native Bitmain ecosystem pool with deep firmware integration. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives products. For fleet deployments above 3 PH/s (equivalent to 7+ units or a single immersion tank), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates.

CapEx beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), immersion tank infrastructure ($2,000 to $50,000 per tank depending on size and sophistication), dielectric fluid fill (200 to 400 liters per 8 unit tank at $2 to $200 per liter depending on fluid selection), circulation pumps and heat exchange infrastructure ($5,000 to $25,000 per rack), fluid monitoring and management systems ($1,000 to $10,000 per deployment). Total immersion CapEx per miner: typically $4,000 to $12,000 beyond miner cost for greenfield deployment. Annual OpEx per unit at 5,304W continuous: electricity at $3,717 at $0.08 per kWh, $3,253 at $0.07 per kWh, $1,858 at $0.04 per kWh industrial hosting rates. Dielectric fluid maintenance ($100 to $500 annually per unit at scale). Spare parts reserves (2 to 3 percent of acquisition annually, lower than air cooled). 3 year TCO per unit at $0.07 per kWh self hosted: approximately $11,096 hardware plus $9,759 electricity plus $800 maintenance plus $5,000 immersion infrastructure amortization equals $26,655 total. 3 year gross revenue at $0.07 per kWh profitability: $8,700 to $13,000. Heat reuse capture adds $1,500 to $6,000 across 3 years in favorable configurations, meaningfully improving 3 year economics.

Within Bitmain S23 generation: S23 Hydro 580TH for flagship efficiency standalone hydro, S23 Hyd 3U 1.16 PH/s for petahash 3U hydro, S23 Air 318TH for air cooled deployment, S23E Hyd 2U 865TH for tier alternative, S21 XP+ Hyd 500TH for premium S21 generation mid tier. Within Bitmain S21 generation: S21 XP Hydro 473TH for universal voltage compact hydro, S21+ Hydro 395TH for universal voltage lower tier, S21e XP Hyd 3U 860TH for 3U value play. For operators diversifying across manufacturers in immersion: Whatsminer M73S+ 540TH represents MicroBT's rack mount tier, Whatsminer M79S 1.35 PH/s represents high power hydro alternative. For operations building modular infrastructure: Proto Rig 819 TH/s provides Block's 10+ year chassis modular architecture as alternative long lifespan deployment model. Cross algorithm fleet diversification: Antminer KS7 for Kaspa, Antminer L11 for Litecoin and Dogecoin merged mining, IceRiver AE3 for Aleo, Antminer Z15 for Zcash, Bitdeer SealMiner A3 Pro Hydro for NASDAQ listed manufacturer alternative. MillionMiner's ASIC hosting service accepts S23 Immersion units at negotiated industrial electricity rates with full immersion tank infrastructure included.

Get a Quote