Bitmain Antminer S23E Hyd 2U (865TH)

Model: S23E Hyd 2U

Nový

865 TH/s SHA-256 hydro-cooled Bitcoin miner from Bitmain in 2U rack format. 8,650W at 10 J/TH efficiency, released April 2026. The mid-tier density variant of Bitmain's current generation S23 hydro lineup, sitting between the standalone S23 Hydro (580 TH at 9.5 J/TH) and the S23 Hyd 3U (1,160 TH at 9.5 J/TH). Slightly less efficient (10 J/TH vs 9.5 J/TH) than the standalone and 3U variants but optimized for maximum 2U rack density: up to 21 units per standard 42U rack delivers 18.2 PH/s per cabinet at approximately 182 kW. 49 percent more hashrate per chassis than the base S23 Hydro at 57 percent more power consumption. 380 to 415V three-phase AC input via industrial three-phase connector. Compact 600 x 483 x 86 mm in 2U rack format at 17 kg net weight. Hydro cooled with closed-loop water circulation at 50 dB whisper-quiet operation. Ethernet 10/100M connectivity. 5 to 45 degrees Celsius operating range with hydro inlet water temperature requirements. 5 to 95 percent humidity tolerance. Compatible with antifreeze, pure water, and deionized water coolant chemistry. 360-day Bitmain factory warranty. Built exclusively for professional data center deployment with hydro cooling infrastructure: closed-loop water cooling system, three-phase electrical service, and industrial CDU/dry cooler heat rejection required. Profitable across all realistic industrial deployment scenarios with break even at approximately $0.163 per kWh under current Bitcoin network conditions. Ships with PSU, power cables, quick start guide, and free DDP worldwide delivery from MillionMiner.

865 TH/s 8650W SHA-256 10 J/TH

Vyberte dostupnost

Množství

Celková cena

$11,699.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bankovní převod | BTC | ETH | USDT

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

865 TH/s

Výkon

8650 W

Účinnost

10.00 J/TH

Hluk

50 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$32.41 $226.87 $972.30
Elektrická energie
-$16.61 -$116.27 -$498.30
Zisk
$15.80 $110.60 $474.00

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 865 TH/s
Spotřeba energie 8650 W
Účinnost 10.00 J/TH
Algoritmus SHA-256
Model S23E Hyd 2U
Rok vydání Dub 2026
Hladina hluku 50 dB
Rozměry 600 x 483 x 86mm
Váha 17 kg
Provozní teplota 5 - 45 °C
vlhkost 5 - 95 %
Typ chlazení Hydro
Formát stojanu 2U

Co je v krabici

S23E Hyd 2U
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Detaily produktu

Bitmain Antminer S23E Hyd 2U 865 TH/s SHA-256 Hydro-Cooled Bitcoin ASIC Miner: The 2026 Density-Optimized Mid Tier of Bitmain's S23 Hydro Family With 10 J/TH Efficiency, 21 Units Per 42U Rack Density, and 380-415V Three-Phase Industrial Deployment

The Bitmain Antminer S23E Hyd 2U produces 865 TH/s of SHA-256 hashrate at 8,650W wall draw and 10 J/TH efficiency in a 2U rack-mountable hydro-cooled chassis for mining Bitcoin (BTC), Bitcoin Cash (BCH), Bitcoin SV (BSV), and all SHA-256 derivative chains. Released April 2026 as the density-optimized mid tier of Bitmain's current generation S23 hydro family, also marketed as the Antminer S23E U2H. ±3 percent hashrate and ±5 percent power tolerance per Bitmain documentation. Hydro cooled with closed-loop water circulation through internal cold plates at 50 dB whisper-quiet operation. 380 to 415V three-phase AC input via industrial three-phase connector. 600 x 483 x 86 mm dimensions in standard 2U rack format at 17 kg net weight (some distributors list 19.1 kg). Ethernet 10/100M connectivity. 5 to 45 degrees Celsius operating range. 5 to 95 percent humidity tolerance. Compatible with antifreeze, pure water, and deionized water coolant chemistry. 360-day Bitmain factory warranty. The S23E Hyd 2U positioning within the family. The S23E Hyd 2U at 865 TH and 8,650W produces 49 percent more hashrate per chassis than the base S23 Hydro (580 TH at 5,510W) at 57 percent more power consumption. The per terahash efficiency tradeoff is modest: 10 J/TH on the 2U variant versus 9.5 J/TH on the standalone S23 Hydro and S23 Hyd 3U variants (the 2U variant is approximately 5 percent less efficient per terahash). The form factor advantage compensates substantially: 2U rack height fits 21 units per standard 42U rack versus 14 units for 3U hardware, delivering 18.2 PH/s per cabinet at approximately 182 kW power consumption. For data center operations measuring performance per rack unit and per facility footprint, the 2U variant captures the highest hashrate density per cabinet across the S23 family. The 5 percent efficiency differential at retail commercial electricity rates equates to approximately $0.85 daily per unit additional electricity cost versus the standalone Hydro at the same hashrate output, or approximately $310 annually per unit. The density advantage of fitting 7 additional units per rack typically outweighs the per-unit efficiency differential at scale. (1,176 characters) The S23 hydro family deployment matrix. Three options for operators choosing within the family. S23 Hydro (standalone) at 580 TH and 5,510W (9.5 J/TH, smallest unit, lowest acquisition cost, 410 x 170 x 209 mm at 13.5 kg, single 19-inch rack slot). S23E Hyd 2U at 865 TH and 8,650W (10 J/TH, this product, maximum 2U density, 600 x 483 x 86 mm at 17 kg). S23 Hyd 3U at 1,160 TH and 11,020W (9.5 J/TH, maximum per-chassis hashrate, 900 x 486 x 132 mm at 21.5 kg, requires 1,000+ mm depth racks). The 2U variant captures the rack density sweet spot: more hashrate per chassis than the standalone, lower acquisition cost than the 3U, and maximum cabinet density when rack space is the binding constraint. For operations where rack space carries real infrastructure cost (typical urban data center deployments where floor area is expensive), the 2U variant wins on per-rack-unit economics. For operations where electricity efficiency is the primary constraint (rural facilities with cheap electricity), the standalone Hydro and 3U variants win on per terahash efficiency. (1,062 characters) The competitive context across manufacturers. MicroBT WhatsMiner M73S+ at 540 TH and 7,200W delivers 13.33 J/TH (33 percent less efficient per terahash than S23E Hyd 2U at 10 J/TH). MicroBT M66S Hydro variants at 18-20 J/TH are previous generation hardware. Bitdeer SealMiner A3 Pro Hydro at 660 TH and 8,250W delivers 12.5 J/TH (25 percent less efficient). Among current generation hydro flagships across all manufacturers, the S23E Hyd 2U leads on per terahash efficiency at this hashrate tier and on rack density per 2U slot. The 2U format competing units from MicroBT or Bitdeer at equivalent hashrate do not exist as of April 2026; the S23E Hyd 2U is the highest-density rack-mount Bitcoin mining hardware currently available. Current Bitcoin mining economics. MillionMiner calculator at $0.08 per kWh retail commercial: $33.75 daily revenue, $16.61 daily electricity, +$17.14 daily profit, +$514 monthly, +$6,256 annually. At $0.05 per kWh industrial rate: approximately +$23.37 daily, +$701 monthly, +$8,530 annually. At $0.04 per kWh: approximately +$25.45 daily, +$764 monthly, +$9,289 annually. At $0.07 per kWh per Mining Now February 2026 data: +$18.95 daily, +$568 monthly, +$6,917 annually. At $0.10 per kWh higher commercial rate: approximately +$12.99 daily, +$4,742 annually. Break even electricity rate at current Bitcoin network conditions is approximately $0.163 per kWh. ROI windows approximately 17 to 22 months at industrial hosting electricity rates depending on BTC price trajectory. ROI is highly sensitive to Bitcoin price: at significantly higher BTC prices, ROI compresses to under 12 months at industrial electricity rates. The S23E Hyd 2U has stronger ROI economics than the standalone S23 Hydro due to higher absolute profit per unit at lower acquisition cost per terahash. (1,083 characters) Industrial hydro deployment requirements. 380 to 415V three-phase AC input via industrial three-phase connector. Standard industrial three-phase service required for deployment. At 380V three-phase draws approximately 13.1 amps per phase; at 415V approximately 12.0 amps per phase. Closed-loop hydro cooling with internal cold plates bonded directly to hash board chips. External CDU (Coolant Distribution Unit) circulating water, deionized water, or water-glycol antifreeze. External heat rejection via dry cooler or cooling tower sized at 8.5+ kW per unit thermal load (29,500 BTU per hour). Standard 19-inch rack mounting in 2U rack slots with quick-disconnect hose fittings for serviceability. Coolant chemistry monitoring quarterly. The S23E Hyd 2U is industrial mining hardware that requires complete data center hydro infrastructure for deployment: not suitable for residential, small commercial, garage, or air-cooled deployment under any circumstances. Form factor and rack density advantages. The S23E Hyd 2U at 600 x 483 x 86 mm and 17 kg fits standard 19-inch rack slots in 2U height format. The 600 mm depth fits within standard 600 mm rack depth or deeper formats. Single-person installation possible with appropriate handling technique. Single hydro hose pair per unit. The 2U format produces 21 units per 42U rack versus 14 units for 3U hardware (50 percent more units per cabinet) and versus 42 units for 1U hardware (though no 1U hydro Bitcoin miners exist at this efficiency tier as of April 2026). The 18.2 PH/s per cabinet density at 182 kW per rack matches the highest practical thermal density for hydro-cooled data center facilities, with thermal infrastructure typically the binding constraint above this density level. Antminer firmware ecosystem. Bitmain's stock Antminer firmware provides web-based pool configuration (up to three pool addresses), real-time hashrate monitoring, power mode selection, fleet management integration, and operational alerting. BraiinsOS+ third-party firmware adds per-chip performance data, advanced autotuning that typically captures 2 to 5 percent additional efficiency, comprehensive monitoring dashboards, and advanced pool management with first-principles stratum implementation. Vnish firmware is another third-party option commonly deployed across Antminer fleets. The S23E Hyd 2U inherits the mature Antminer firmware ecosystem with all existing third-party tools supporting the platform from launch. Note that installing third-party firmware may affect manufacturer warranty coverage. Bitmain manufacturer and warranty context. Bitmain Technologies, founded in Beijing in 2013, is the largest ASIC mining hardware manufacturer by shipment volume globally. The Antminer hydro series has been the industrial data center standard since the S19 Pro+ Hyd era. Manufacturing scale, firmware maturity, distributor network breadth, and support infrastructure are unmatched among ASIC mining hardware companies. The S23E Hyd 2U benefits from Bitmain's established supply chain, RMA processes, and decade-plus field reliability history. The 360-day factory warranty represents Bitmain's standard coverage for new generation hardware. Some distributors offer extended 2-year coverage. Warranty claims processed through MillionMiner support with direct Bitmain channel escalation as needed. Ships from MillionMiner with miner, PSU, power cables, quick start guide, 360-day Bitmain factory warranty, and free DDP worldwide delivery covering all customs clearance, import duties, and taxes.

Bitmain Antminer S23E Hyd 2U 865 TH/s: The Density-Optimized Mid Tier of

The Bitmain Antminer S23E Hyd 2U produces 865 TH/s of SHA-256 hashrate at 8,650W and 10
J/TH efficiency in a 2U rack-mountable hydro-cooled chassis for mining Bitcoin (BTC) and
Bitcoin Cash (BCH). Released April 2026. The density-optimized middle tier of Bitmain's S23
hydro family, sitting between the standalone S23 Hydro (580 TH at 9.5 J/TH) and the S23 Hyd
3U (1,160 TH at 9.5 J/TH). The S23E Hyd 2U positioning. The S23E Hyd 2U at 865 TH and 8,650W produces 49 percent
more hashrate per chassis than the base S23 Hydro (580 TH) at 57 percent more power
consumption. The efficiency tradeoff is modest: 10 J/TH on the 2U variant versus 9.5 J/TH on
the standalone Hydro and 3U variants (5 percent less efficient per terahash). The form factor
advantage compensates: 2U rack height fits 21 units per standard 42U rack versus 14 units for
3U hardware, delivering 18.2 PH/s per cabinet at approximately 182 kW power consumption.
For data center operations measuring performance per rack unit and per facility footprint, the 2U
variant captures the highest hashrate density per cabinet across the S23 family. The S23 hydro family deployment matrix. Three options for operators choosing within the family.
S23 Hydro (standalone) at 580 TH and 5,510W (9.5 J/TH, smallest unit, lowest acquisition cost).
S23E Hyd 2U at 865 TH and 8,650W (10 J/TH, this product, maximum 2U density). S23 Hyd 3U
at 1,160 TH and 11,020W (9.5 J/TH, maximum per-chassis hashrate, 3U format). The 2U
variant captures the rack density sweet spot: more hashrate per chassis than the standalone,
lower acquisition cost than the 3U, and maximum cabinet density when rack space is the
binding constraint. For operations where rack space carries real infrastructure cost, the 2U
variant wins on per-rack-unit economics. The competitive context. MicroBT WhatsMiner M73S+ at 540 TH and 7,200W delivers 13.33
J/TH (33 percent less efficient per terahash than S23E Hyd 2U). Bitdeer SealMiner A3 Pro
Hydro at 660 TH and 8,250W delivers 12.5 J/TH (25 percent less efficient). Among current
generation hydro flagships across all manufacturers, the S23E Hyd 2U leads on per terahash
efficiency at this hashrate tier and on rack density per 2U slot. The S23E Hyd 2U is the
highest-density rack-mount Bitcoin mining hardware currently available across all
manufacturers. Current Bitcoin mining economics. MillionMiner calculator at $0.08 per kWh: $33.75 daily
revenue, $16.61 daily electricity, +$17.14 daily profit, +$514 monthly, +$6,256 annually. At $0.05
per kWh industrial rate: approximately +$23.37 daily, +$8,530 annually. At $0.04 per kWh:
approximately +$25.45 daily, +$9,289 annually. At $0.07 per kWh per Mining Now February
2026 data: +$18.95 daily, +$6,917 annually. At $0.10 per kWh higher commercial rate:
approximately +$12.99 daily profit. Break even electricity rate at current Bitcoin network
conditions is approximately $0.163 per kWh. ROI windows approximately 17 to 22 months at
industrial hosting electricity rates depending on BTC price trajectory. Industrial deployment requirements. 380 to 415V three-phase AC input via industrial
three-phase connector. Closed-loop hydro cooling with internal cold plates bonded directly to
hash board chips. External CDU circulating water/deionized water/water-glycol antifreeze.
External heat rejection via dry cooler or cooling tower sized at 8.5+ kW per unit thermal load.
Standard 19-inch rack mounting in 2U rack slots with quick-disconnect hose fittings.
Approximately 29,500 BTU per hour heat output handled silently through hydro cooling. Not
suitable for residential, small commercial, or air-cooled deployment. 600 x 483 x 86 mm in 2U rack format at 17 kg net weight (19.1 kg per some distributor listings).
Hydro cooled at 50 dB. Ethernet 10/100M connectivity. 5 to 45 degrees Celsius operating range.
5 to 95 percent humidity tolerance. 360-day Bitmain factory warranty. Mines Bitcoin (BTC),
Bitcoin Cash (BCH), Bitcoin SV (BSV), and all SHA-256 derivative chains.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Bitmain Antminer S23E Hyd 2U 865 TH/s SHA-256 Hydro-Cooled Rack Density

Bitmain's April 2026 mid-tier density variant of the S23 hydro lineup. 865
TH/s SHA-256 at 8,650W and 10 J/TH efficiency in 2U rack format. The density-optimized
middle tier sitting between the standalone S23 Hydro (580 TH at 9.5 J/TH) and the S23 Hyd 3U
(1,160 TH at 9.5 J/TH). 21 units per standard 42U rack delivers 18.2 PH/s per cabinet at
approximately 182 kW. 49 percent more hashrate per chassis than the base S23 Hydro at 57
percent more power consumption. 380 to 415V three-phase AC input. 600 x 483 x 86 mm in 2U
rack format at 17 kg. Hydro cooled at 50 dB. Ethernet 10/100M connectivity. 5 to 45 degrees
Celsius operating range. 360-day Bitmain factory warranty. Built exclusively for professional
data center deployment: hydro cooling infrastructure, three-phase electrical service, and
industrial heat rejection required. Profitable across all realistic industrial deployment scenarios
with break even at approximately $0.163 per kWh under current Bitcoin network conditions.
Ships with PSU, cables, quick start guide, and free DDP worldwide from MillionMiner. (1,071
characters)

Maximální hustota 2U racku při 18,2 PH/s na skříň

21 units per standard 42U rack at 182 kW. Highest-density rack-mount Bitcoin mining hardware currently available. 50 percent more units per cabinet than 3U hardware.

Mid-Tier Pricing for Density-Optimized Deployment

49 percent more hashrate per chassis than the base S23 Hydro at 57 percent more power. Lower acquisition cost than the S23 Hyd 3U with similar density math.

Silná ekonomika průmyslového hostingového výkonu při 10 J/TH

Break even at approximately $0.163 per kWh. +$8,530 annual profit at $0.05 per kWh industrial rates. ROI 17-22 months at industrial electricity.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

865 TH/s SHA-256 at 8,650W and 10 J/TH efficiency on Bitmain's April 2026 generation S23E Hyd 2U chassis (also marketed as Antminer S23E U2H). ±3 percent hashrate and ±5 percent power tolerance per Bitmain documentation. The mid-tier density variant of the S23 hydro family, delivering 49 percent more hashrate per chassis than the base S23 Hydro (580 TH) and 75 percent of the S23 Hyd 3U hashrate (1,160 TH) in a more compact 2U rack format.

49 percent more hashrate at 57 percent more power, with slightly less efficient per terahash economics. Standalone S23 Hydro at 580 TH and 5,510W (9.5 J/TH) versus S23E Hyd 2U at 865 TH and 8,650W (10 J/TH): the 2U variant delivers 49 percent more hashrate per chassis, but at 5 percent less per terahash efficiency. The 2U variant wins on rack density (21 units per 42U cabinet versus standalone hydro stacking constrained by chassis depth) and on per-chassis hashrate consolidation. The standalone wins on per terahash efficiency and on per-unit acquisition cost. For density-constrained deployments, the 2U variant captures better total economics.

Lower acquisition cost per chassis with marginally less efficient per terahash economics, but higher rack density per cabinet. S23E Hyd 2U at 865 TH and 8,650W (10 J/TH) versus S23 Hyd 3U at 1,160 TH and 11,020W (9.5 J/TH): the 3U variant delivers 34 percent more hashrate per chassis at 27 percent more power consumption with 5 percent better per terahash efficiency. The 2U variant wins on rack density (21 units per 42U cabinet versus 14 for 3U, a 50 percent density advantage) and on lower acquisition cost per unit. The 3U variant wins on per-chassis hashrate and on per terahash efficiency. For maximum cabinet hashrate at fixed rack space, the 2U variant captures more total hashrate per 42U cabinet (18.2 PH versus 16.24 PH for 3U).

The S23E Hyd 2U wins decisively on per terahash efficiency. MicroBT WhatsMiner M73S+ at 540 TH and 7,200W delivers 13.33 J/TH (33 percent less efficient per terahash). Bitdeer SealMiner A3 Pro Hydro at 660 TH and 8,250W delivers 12.5 J/TH (25 percent less efficient). The S23E Hyd 2U also wins on absolute hashrate per chassis at this tier. Among current generation hydro flagships across all manufacturers, the S23E Hyd 2U leads on per terahash efficiency at this hashrate level and on rack density per 2U slot. No competing 2U format hydro Bitcoin miner from other manufacturers matches the S23E Hyd 2U's combination of efficiency, density, and per-chassis hashrate as of April 2026.

Yes across all realistic industrial deployment scenarios. At $0.08 per kWh: +$17.14 daily profit, +$514 monthly, +$6,256 annually. At $0.05 per kWh industrial rate: approximately +$23.37 daily, +$8,530 annually. At $0.04 per kWh: approximately +$25.45 daily, +$9,289 annually. At $0.07 per kWh per Mining Now February 2026 data: +$18.95 daily, +$6,917 annually. At $0.10 per kWh higher commercial rate: approximately +$12.99 daily profit, +$4,742 annually. Break even electricity rate at current Bitcoin network conditions is approximately $0.163 per kWh. ROI windows approximately 17 to 22 months at industrial hosting electricity rates depending on BTC price trajectory.

380 to 415V three-phase AC input via industrial three-phase connector. Standard industrial three-phase service required for deployment. At 380V three-phase draws approximately 13.1 amps per phase; at 415V approximately 12.0 amps per phase. Compatible with European and Asian three-phase commercial service, US 480V three-phase service (with appropriate transformer to 415V), and industrial mining facility service. Single-phase deployment is not supported and not possible at this power consumption level. The electrical infrastructure requirement makes the S23E Hyd 2U exclusively suitable for data center, industrial mining facility, or large commercial deployment with three-phase electrical service.

Closed-loop hydro cooling with internal cold plates bonded directly to hash board chips. External CDU (Coolant Distribution Unit) circulating water, deionized water, or water-glycol antifreeze. External heat rejection via dry cooler or cooling tower sized at 8.5+ kW per unit thermal load (29,500 BTU per hour). Standard 19-inch rack mounting in 2U slots with quick-disconnect hose fittings for serviceability. Coolant chemistry monitoring quarterly. Compatible with existing Bitmain hydro infrastructure (S19 Pro+ Hyd, S21 Hydro, S23 Hydro deployments) using the same plumbing standards. MillionMiner Equipment category includes Lianli radiators and CDU systems compatible with S23E Hyd 2U deployment.

50 dB hydro-cooled operation, comparable to a quiet office or normal conversation level. Substantially quieter than air-cooled equivalents at 75 dB. Hydro cooling eliminates the high-RPM exhaust fans that produce most ASIC noise. The remaining 50 dB noise comes from coolant pumps and minimal internal airflow components. Suitable for shared data center spaces and indoor mining facilities without specialized acoustic isolation requirements. Multi-unit deployment in standard data center configurations does not produce additive noise beyond comfortable industrial workspace levels.

600 x 483 x 86 mm in standard 2U rack format at 17 kg net weight per MillionMiner specification (some distributors including Mining Now list 19.1 kg, possibly accounting for full coolant or different measurement methodology). The 600 mm depth fits within standard 600 mm rack depth. Standard 19-inch rack mounting compatible with existing data center rack infrastructure. Single-person installation possible with appropriate lifting technique. Lighter than the S23 Hyd 3U (21.5 kg) and slightly heavier than the standalone S23 Hydro (13.5 kg).

5 to 45 degrees Celsius operating range per MillionMiner specification. The hydro variants typically require 20°C minimum inlet water temperature to prevent thermal cycling damage to chip cold plates. For external dry cooler deployment with controlled outlet temperatures, the S23E Hyd 2U follows the same Bitmain hydro family operating envelope: maximum ambient temperature approximately 30°C with 35°C coolant outlet, 40°C ambient with 45°C coolant outlet, 45°C ambient with 50°C coolant outlet. Storage temperature -20 to +70°C. Humidity tolerance 5 to 95 percent. The hydro cooling system tolerates wider ambient temperature range than air-cooled equivalents because heat rejection is decoupled from intake air temperature.

Bitcoin (BTC) is the primary target on the SHA-256 algorithm. Also mineable: Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), eCash (XEC), DigiByte (DGB) on SHA-256d, and any other SHA-256 derivative chain. Cannot mine Litecoin (Scrypt), Kaspa (KHeavyHash), Ethereum Classic (EtcHash), Aleo (zkSNARK), Alephium (Blake3), or any algorithm outside SHA-256. Most operators mine BTC directly at major pools (Foundry, AntPool, F2Pool, ViaBTC, Luxor, Braiins Pool) for maximum revenue stability.

Yes. The S23E Hyd 2U ships with an integrated PSU sized for the 8,650W rated load, along with power cables and quick start guide. Box contents per MillionMiner: Antminer S23E Hyd 2U unit, PSU, power cables, and quick start guide. Contents may vary by batch with exact items in order confirmation. The included PSU eliminates external power brick sourcing decisions and connector compatibility concerns. The PSU uses industrial three-phase connector standard for Bitmain hydro hardware.

Industrial data center deployment with hydro cooling infrastructure. Step one: verify three-phase 380-415V electrical circuit availability with appropriate breaker capacity (13 amps per phase at 380V). Step two: install in standard 19-inch rack with appropriate 2U slot dimensions. Step three: connect hydro cooling supply and return hoses via quick-disconnect fittings to facility CDU manifold. Step four: connect three-phase power cable to industrial connector. Step five: connect Ethernet cable to data center network switch. Step six: find miner IP through Bitmain IP Reporter or DHCP table, open Antminer web interface, login with default root/root credentials (change immediately for security), configure BTC pool URL and BTC wallet address. Step seven: verify hashrate stabilizes at approximately 865 TH/s within 15 to 20 minutes of startup.

Yes. MillionMiner hosting accepts S23E Hyd 2U units at managed hydro-cooled industrial facilities. At $0.05 per kWh industrial hosting rates: approximately +$23.37 daily profit per unit, +$8,530 annually. At $0.04 per kWh: approximately +$25.45 daily profit per unit, +$9,289 annually. Hosting eliminates facility CapEx, three-phase electrical infrastructure investment, hydro cooling system construction, industrial CDU and dry cooler installation, day-to-day operational overhead, and specialized hydro mining facility expertise requirements. For institutional and industrial buyers without existing hydro mining facility infrastructure, hosting through MillionMiner is the practical path to deploying the S23E Hyd 2U at scale. Contact MillionMiner for current hosting rates and facility availability.

360-day Bitmain factory warranty per BT-Miners distributor documentation (some sources cite 365 days). Some distributors offer extended 2-year coverage. Covers manufacturing defects and hardware failures under normal operating conditions. Tampering with warranty seal, use of incompatible PSU, exceeding rated voltage input, improper coolant chemistry, deployment outside rated operating temperature range, or physical damage from shipping voids coverage. Warranty claims processed through MillionMiner support with direct Bitmain channel escalation as needed.

Industrial hydro miner maintenance protocols. Quarterly coolant chemistry inspection (pH, conductivity, biological growth markers). Semi-annual coolant replacement or filtration based on system size and chemistry stability. Annual hash board inspection for chip-level performance variance. Continuous hashrate monitoring through Antminer web interface or BraiinsOS+ dashboard with alerting on temperature, hashrate, and power deviations. Quarterly hose fitting inspection for leakage or wear. The S23E Hyd 2U platform has limited field reliability data as of April 2026 (less than 1 month in market) but inherits the mature Bitmain hydro hardware design lineage from the S19 Pro+ Hyd through S21 Hydro and S23 Hydro generations with no expected reliability issues.

BraiinsOS+ supports the Antminer S23 series for autotuning optimization and is expected to support the S23E Hyd 2U variant from launch. The firmware provides per-chip performance data, advanced pool management, and comprehensive monitoring beyond Bitmain's stock firmware. Operators using BraiinsOS+ on S23 hardware typically achieve 2 to 5 percent additional efficiency improvements over stock firmware, equivalent to approximately $130 to $325 annually per S23E Hyd 2U unit at $0.08 per kWh electricity. Vnish firmware is another third-party option. Note that installing third-party firmware may affect manufacturer warranty coverage.

Choose the S23E Hyd 2U when rack density is the binding constraint. The 2U format delivers maximum hashrate per rack unit (18.2 PH per 42U cabinet versus 9.7 PH for standalone Hydro deployment or 16.24 PH for 3U) at acquisition pricing between the standalone and 3U variants. Choose the standalone S23 Hydro for lowest per-unit acquisition cost or for deployment in mixed S19/S21 hydro fleet integration. Choose the S23 Hyd 3U for maximum hashrate per chassis (1.16 PH single management endpoint) or when 3U rack slots are abundant. The 2U variant captures the rack density sweet spot for typical urban data center deployments where floor area carries real cost.

Buy the S23E Hyd 2U if you operate or are constructing an industrial data center with three-phase electrical service and hydro cooling infrastructure where rack density is the binding constraint, you want maximum hashrate per 42U cabinet across the S23 family, you are positioned for long term Bitcoin price growth, you have access to industrial hosting electricity rates for maximum profitability, you are running existing Bitmain S19 Pro+ Hyd or S21 Hydro fleets where S23 integration provides natural refresh, or you want a balance between per-unit acquisition cost and per-chassis hashrate. Consider the standalone S23 Hydro at 580 TH if you want lowest per-unit acquisition cost. Consider the S23 Hyd 3U at 1.16 PH/s if you operate at maximum density scale. Avoid the S23E Hyd 2U if you do not have data center scale hydro infrastructure or three-phase electrical service.

Within the S23 hydro family: standalone S23 Hydro at 580 TH for lower-cost per-unit deployment, S23 Hyd 3U at 1,160 TH for maximum per-chassis hashrate, S23 Immersion at 442 TH for immersion deployment infrastructure, S23 air-cooled at 318 TH for non-hydro deployment. For lower acquisition cost: S21 XP+ Hyd at 500 TH ($9,500), S21 XP HYDRO at 473 TH ($6,899), S21e XP Hydro at 860 TH ($11,649). Competing manufacturer hydro: MicroBT WhatsMiner M73S+ at 540 TH for higher hashrate alternative, Bitdeer SealMiner A3 Pro Hydro at 660 TH for Bitdeer ecosystem alternative. For complete data center infrastructure: MillionMiner Equipment category includes Lianli hydro radiators and CDU systems, Mining Containers for portable industrial deployment, Racks & Cabinets for proper rack mounting. For algorithm diversification beyond Bitcoin: Bitmain Antminer KS7 for Kaspa, Bitmain Antminer L11 for Litecoin and Dogecoin, Bitmain Antminer E11 for Ethereum Classic. For operators wanting hosting rather than self deployment, MillionMiner ASIC hosting services accept S23E Hyd 2U units. (1,072 characters)

Get a Quote