226 TH/s air cooled SHA-256 Bitcoin miner at 3,140W and 13.89 J/TH efficiency, the mid bin of MicroBT's M70 standard voltage air cooled tier in the M70 generation. Manufacturer headline spec runs 13.5 J/TH across the broader 226 to 258 TH/s binning range per Blockspace Media launch coverage, with power draw between 3,140W and 3,500W in upper bin configuration. Positioned between the top bin M70S+ (244 to 280 TH/s at 12.5 J/TH) and base M70 (214 to 236 TH/s at 14.5 J/TH) across an identical 430 x 155 x 226 mm chassis. Runs on 220 to 240V single phase power available in most commercial and dedicated residential settings, with no three phase infrastructure required. Most compact chassis in the M70 generation at 13.5 kg. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

226 TH/s 3140W SHA-256 13.89 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

226 TH/s

Výkon

3140 W

Účinnost

13.89 J/TH

Hluk

75 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$8.45 $59.15 $253.50
Elektrická energie
-$6.03 -$42.21 -$180.90
Zisk
$2.43 $17.01 $72.90

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 226 TH/s
Spotřeba energie 3140 W
Účinnost 13.89 J/TH
Algoritmus SHA-256
Model Whatsminer M70S
Rok vydání Prosince 2025
Hladina hluku 75 dB
Rozměry 430 x 155 x 226mm
Váha 13.5 kg
Napětí AC 220-240V
Rozhraní Ethernet
Provozní teplota 5 - 45 °C
vlhkost 5 - 95 %
Typ chlazení Air

Co je v krabici

Whatsminer M70S
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Detaily produktu

MicroBT Whatsminer M70S 226 TH/s Air Cooled 220V Bitcoin Miner: Mid Bin Specifications and Single Phase Deployment Guide

The Whatsminer M70S sits in the middle of MicroBT's M70 standard voltage air cooled tier, positioned between the top bin M70S+ (244 to 280 TH/s at 12.5 J/TH) and base M70 (214 to 236 TH/s at 14.5 J/TH). All three M70 variants share the identical 430 x 155 x 226 mm chassis, 13.5 kg weight, 220 to 240V single phase power requirements, and Whatsminer firmware. Chip binning grade differentiates them. MillionMiner rated spec: 226 TH/s at 3,140W and 13.89 J/TH efficiency. Manufacturer headline specs per Blockspace Media launch coverage at Bitcoin MENA 2025, along with Zeus Mining and Hashrate Index, document the broader binning range at 226 to 258 TH/s and 13.5 J/TH efficiency. Power draw scales between 3,140W rated mode and 3,500W in upper bin or overclock configuration. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Mid bin economics favor the M70S for operators wanting the strongest acquisition cost to performance ratio in the M70 lineup. Chip binning produces natural performance distribution from silicon fabrication, and mid bin captures the largest volume of that distribution. Top bin silicon (M70S+) charges the price premium matching its 12.5 J/TH efficiency leadership. Base bin silicon (M70) sells at the floor for volume fleet buyers maximizing unit count per capital dollar. Mid bin sits between, meaningfully better efficiency than base grade at smaller price premium than top grade commands. The efficiency comparison is quantifiable. M70S at 13.89 J/TH (MillionMiner rated) or 13.5 J/TH (manufacturer headline) versus M70S+ at 12.87 J/TH or 12.5 J/TH. At $0.04 per kWh industrial rates, the per unit daily electricity difference runs roughly $0.10. At $0.08 per kWh: approximately $0.20 daily per unit. Across a 10 unit deployment, that is $2 daily. Over a 3 year horizon at $0.06 per kWh, accumulated efficiency gap totals approximately $1,600 per 10 unit fleet. Whether this justifies the M70S+ acquisition premium depends on the specific price differential at your supplier. The 220 to 240V single phase requirement is the defining feature of the M70 series and the key to M70S accessibility. Unlike the M72 series (380 to 480V three phase), the M70S runs on the same single phase power available in most commercial buildings worldwide and many dedicated residential installations. In European, Middle Eastern, Asian, Latin American, and African markets on 220 to 240V standard service, the M70S plugs into circuits without voltage conversion. In North American facilities with 240V outlets via NEMA 6 or NEMA L6 configurations, the M70S also operates without three phase service or step up transformers. Thermal planning matters. At 3,140W per unit, each machine produces roughly 10,700 BTU of heat per hour. A 10 unit deployment generates 31.4 kW of continuous heat requiring exhaust ventilation sized to the load. Room temperature rises quickly without adequate airflow planning. Ventilation design should target at least 3 to 5 complete air changes per hour in typical deployment spaces, with exhaust capacity scaled to total fleet thermal output plus thermal margin for hot weather operation. Physical specifications: 430 x 155 x 226 mm at 13.5 kg. Most compact chassis in the M70 generation and lightest MicroBT Bitcoin miner currently shipping. Lighter than the M72 series (25.5 kg) and dramatically lighter than the M79 immersion tier (37 kg). Compact footprint enables shelf or rack placement in ventilated rooms, maximizing unit count per physical area. Bitcoin mining economics at 226 TH/s: MillionMiner's $0.08 per kWh onsite calculator shows $7.37 daily revenue, $6.03 electricity, $1.34 net profit per day. At $0.07 per kWh industrial rates: $5.28 daily electricity, netting $2 daily. At $0.04 per kWh negotiated industrial rates: $3.01 daily electricity, netting $4 daily profit per unit. Upper bin M70S output at 258 TH/s improves daily revenue 14 percent over the 226 TH/s floor rate. Economic viability at scale requires industrial electricity below $0.07 per kWh. 75 dB four fan air cooling produces industrial noise unsuitable for residential living spaces without sound insulation. Ethernet 10/100M management through standard Whatsminer firmware with Foreman, Awesome Miner, and Hive OS compatibility. C19 power cable standard. PSU ships included. 360 day MicroBT manufacturer warranty. Free DDP delivery worldwide from MillionMiner.

MicroBT Whatsminer M70S 226 TH/s: Mid Bin Value in the M70 Single Phase Air

The M70S occupies the value position in MicroBT's M70 standard
voltage air cooled tier. Same 3,140W rated power draw as the M70S+ and M70, same compact
430 x 155 x 226 mm chassis, same 220 to 240V single phase requirements, same Whatsminer
firmware. Chip binning grade and correspondingly different acquisition cost differentiate the
variants.
MillionMiner rated spec: 226 TH/s at 3,140W and 13.89 J/TH. Manufacturer headline per
Blockspace Media, Zeus Mining, and Hashrate Index documents the broader binning range at
226 to 258 TH/s with 13.5 J/TH efficiency and power draw scaling to 3,500W in upper bin
configuration. Real world output depends on batch binning.
Mid bin typically delivers the best acquisition cost to performance ratio because it captures the
largest volume of the natural production distribution. Top bin silicon (M70S+) commands the
price premium matching its 12.5 J/TH efficiency peak. Base bin silicon (M70) sells at the floor for
volume fleet buyers. Mid bin sits between, meaningfully better efficiency than base grade at
smaller premium than top grade commands.
The 220 to 240V single phase requirement keeps the M70S accessible. Standard commercial
circuits in most regions plus dedicated 240V residential outlets in North America. Small
commercial operations running 5 to 20 units deploy without three phase service. 75 dB, four fan
air cooling. Ethernet management through standard Whatsminer firmware.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Whatsminer M70S 226 TH/s Air Cooled Bitcoin Miner

Mid bin of MicroBT's M70 standard voltage air cooled tier, positioned
between the top bin M70S+ (244 to 280 TH/s at 12.5 J/TH) and base M70 (214 to 236 TH/s at
14.5 J/TH). MillionMiner rated spec: 226 TH/s at 3,140W and 13.89 J/TH. Manufacturer headline
at 13.5 J/TH across the 226 to 258 TH/s binning range with power draw scaling to 3,500W in
upper bin configuration per Blockspace Media launch coverage. Mid bin typically offers the
strongest acquisition cost to performance ratio. Runs on 220 to 240V single phase power
available in most commercial and dedicated residential settings, no three phase infrastructure
required. Most compact chassis in the M70 generation at 430 x 155 x 226 mm and 13.5 kg.
Shared firmware and fleet management tools with every M70 generation model regardless of
cooling type.

226 TH/s Mid Bin Value Pick

Middle of the M70 silicon binning distribution. Better efficiency than base M70 at smaller premium than top bin M70S+ commands.

13.5 J/TH Manufacturer Headline

MillionMiner rated at 13.89 J/TH floor. Blockspace Media and Zeus Mining document 13.5 J/TH across the 226 to 258 TH/s binning range.

220 to 240V Single Phase Simplicity

Standard commercial circuits, no three phase, no transformers, no electrical upgrades. Most compact M70 chassis at 13.5 kg.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

The M70S produces 226 TH/s of SHA-256 hashrate at 3,140W and 13.89 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Blockspace Media, Zeus Mining, and Hashrate Index document the broader binning range at 226 to 258 TH/s with 13.5 J/TH efficiency and power scaling to 3,500W in upper bin configuration. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output depends on batch binning, ambient temperature, and operating conditions.

Same 3,140W rated power draw across all three variants. Same 430 x 155 x 226 mm chassis, same 13.5 kg weight, same 220 to 240V single phase requirements. Hashrate and efficiency differences come from chip binning. M70 base: 214 to 236 TH/s at 14.5 J/TH. M70S mid (this product): 226 to 258 TH/s at 13.5 J/TH. M70S+ top: 244 to 280 TH/s at 12.5 J/TH. Mid bin delivers 6 percent more hashrate than base at 7 percent better efficiency, at smaller price premium than top bin commands.

Acquisition cost to performance ratio. Mid bin silicon captures the largest volume of natural chip production distribution, which typically translates to the best acquisition cost per TH/s in any product lineup. Top bin silicon commands the price premium matching its 12.5 J/TH efficiency peak. If the per unit price gap between M70S and M70S+ is less than $250 at your supplier, the M70S+ typically wins on total lifetime economics at $0.06 per kWh industrial rates over 3 year deployments. At larger price gaps, the M70S value proposition strengthens. Run the math with your specific supplier pricing.

220 to 240V single phase commercial or residential power through a C19 power cable connection. At 240V: approximately 13 amps continuous draw at 3,140W rated mode, or 15 amps at 3,500W upper bin mode. Fits within standard 20 amp circuits with headroom. Works on European Schuko outlets (230V), UK BS 1363 (230V with rated adapters), and most international 220 to 240V infrastructure. In North America: requires 240V NEMA 6 or NEMA L6 outlets, available in commercial settings and accessible through dedicated residential circuits. Does not require three phase power, step up transformers, or specialized electrical upgrades.

Yes, with appropriate infrastructure and noise tolerance. Requirements: dedicated 220 to 240V 20 amp circuit, dedicated mining space separate from living areas due to 75 dB noise output, adequate ventilation to dissipate 3.1 kW continuous thermal load (approximately 10,700 BTU per hour). Deploy in garages, basements with sound insulation, outbuildings, or dedicated mining rooms. Not suitable for living spaces, bedrooms, home offices, or shared environments without industrial grade sound insulation.

At MillionMiner's $0.08 per kWh onsite calculator: $7.37 daily revenue, $6.03 electricity, $1.34 net profit per day. At $0.07 per kWh industrial rates: $5.28 daily electricity, netting $2 daily. At $0.04 per kWh negotiated industrial rates: $3.01 daily electricity, netting $4 daily profit per unit. Upper bin M70S output at 258 TH/s improves daily revenue 14 percent over the 226 TH/s floor rate. Home deployments at $0.10 per kWh typically run marginal or negative when accounting for hardware depreciation.

Jakákoli kryptoměna založená na SHA-256 proof of work. Bitcoin (BTC) je hlavním cílem. Další kompatibilní mince zahrnují Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB) a DigiByte (DGB SHA-256 řetězec). Sloučené těžení BTC spolu s BCH a BSV prostřednictvím podporujících poolů, jako jsou ViaBTC a F2Pool, přidává marginální sekundární příjmy bez snížení příspěvku na hash rate Bitcoinu.

Yes. All three M70 variants share identical chassis, power requirements, and Whatsminer firmware. Mix bins freely within fleets based on acquisition cost optimization and deployment strategy. Common pattern: majority M70S units for value, some M70S+ units where efficiency matters most, some M70 base units where budget is tightest. Fleet management handles mixed bin deployments transparently through unified Whatsminer firmware dashboards.

Residential or small commercial setup. Step one: verify 220 to 240V circuit with 20 amp capacity. Step two: ensure adequate ventilation in deployment space. Step three: connect PSU to outlet using the included C19 power cable. Step four: connect Ethernet cable to router or switch. Step five: power on, find miner IP through router DHCP client list or IP scanner tool, open web interface, configure pool URL and Bitcoin wallet, verify hashrate reaches 219+ TH/s within 10 to 15 minutes.

75 dB is standard industrial ASIC noise, comparable to a vacuum cleaner at close range. Not suitable for residential living spaces, bedrooms, home offices, or shared office environments. Appropriate deployment locations include dedicated mining rooms, garages with proper ventilation, basements with sound insulation, outbuildings or sheds, shipping container installations, warehouse mining operations, and professional hosting facilities. Sound insulation boxes marketed for ASIC deployment can reduce noise by 15 to 20 dB but require attention to thermal management.

3,140W per unit produces roughly 10,700 BTU of heat per hour. A 10 unit deployment generates 31.4 kW of continuous heat requiring exhaust ventilation sized to the load. Ventilation design should target at least 3 to 5 complete air changes per hour in typical deployment spaces, with exhaust capacity scaled to total fleet thermal output plus 25 to 30 percent margin for hot weather operation. Dedicated mining spaces typically use exhaust fans rated 600 to 1,500 CFM depending on fleet size.

Standard air cooled ASIC maintenance. Monthly fan cleaning with compressed air to clear dust buildup. Quarterly hashboard connector inspection. Semi annual firmware updates when MicroBT releases patches. Continuous ambient temperature monitoring to keep the unit within the 5 to 45 degree Celsius operating range. Every 18 to 24 months at full duty cycle, expect at least one fan replacement per unit due to bearing wear. Budget 3 to 5 percent of acquisition cost annually for replacement fans and parts.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share with competitive FPPS payouts. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts reducing daily variance. For mid sized commercial fleets above 2.3 PH/s (equivalent to 10+ M70S units), negotiated pool fees below standard 1 to 2 percent are typically available.

A standard 100 amp subpanel at 240V supports approximately 7 M70S units at rated 3,140W producing 1,582 TH/s aggregate. A 200 amp commercial service supports approximately 14 M70S units producing 3,164 TH/s aggregate. For dedicated mining facilities with three phase to single phase branch circuits, larger deployments become practical. Compact 13.5 kg chassis allows shelf or rack placement optimizing unit count per physical area.

M70S: 226 to 258 TH/s at 3,140 to 3,500W and 13.5 J/TH headline on 220 to 240V single phase. Antminer S21+: 235 TH/s at 3,876W and 16.5 J/TH on 200 to 277V single phase. The M70S leads meaningfully on efficiency at 13.5 J/TH versus the S21+ at 16.5 J/TH. The S21+ leads on absolute hashrate per unit at 235 TH/s versus 226 TH/s at the M70S floor. At upper bin M70S output of 258 TH/s, the M70S wins on both metrics. For operators optimizing efficiency, the M70S is the better choice at this hashrate class.

M70S: 226 to 258 TH/s at 13.5 J/TH headline on 220 to 240V single phase. Antminer S21: 200 TH/s at 3,500W and 17.5 J/TH on 200 to 277V. The M70S leads on both hashrate and efficiency. For operators prioritizing efficiency at the 3 to 3.5 kW air cooled power class, the M70S is the stronger choice over the older S21. The newer Bitmain Antminer S23 generation at 10 J/TH liquid cooled provides a different positioning entirely.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from inadequate cooling or ventilation, operation outside the 5 to 45 degree Celsius range, power surge damage from inadequate electrical protection, physical mishandling, and unauthorized firmware modifications. MillionMiner routes warranty claims through direct MicroBT channels for faster resolution than secondary market purchases provide.

Yes. MillionMiner operates managed hosting facilities with 220 to 240V single phase service and ventilation infrastructure capable of supporting M70S deployments. Hosted deployment eliminates facility infrastructure CapEx for operators preferring turnkey air cooled deployment. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M70S units automatically through network scanning. Mixed brand fleets (MicroBT alongside Bitmain, Bitdeer, or Canaan hardware) handle through unified dashboards with brand specific monitoring metrics where applicable. Mixed cooling type fleets (M70S air alongside M79S immersion or M73 hydro) manage through the same Whatsminer interface with cooling specific monitoring metrics appearing where applicable.

Within MicroBT's M70 standard voltage air cooled tier: the M70S+ at 244 to 280 TH/s is the top bin upgrade path, and M70 at 214 to 236 TH/s is the base bin alternative for volume fleet buyers. Cross family at MicroBT: M72 and M72S cover the 4 kW industrial voltage air tier on three phase, M76 series covers the 5.2 kW immersion tier, M73 series covers rack mount hydro, M78 and M79 series cover higher power liquid cooling tiers. Cross brand single phase alternatives: the Antminer S21+ at 235 TH/s and 16.5 J/TH, Antminer S21 XP at 270 TH/s and 13.5 J/TH, Canaan Avalon A16XP at 12.8 J/TH provide vendor diversification. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining on separate infrastructure. MillionMiner's ASIC hosting service accepts M70S units at negotiated industrial electricity rates.

Get a Quote