Nenašly se žádné produkty pro „“
MicroBT
Model: Whatsminer M70S
226 TH/s air cooled SHA-256 Bitcoin miner at 3,140W and 13.89 J/TH efficiency, the mid bin of MicroBT's M70 standard voltage air cooled tier in the M70 generation. Manufacturer headline spec runs 13.5 J/TH across the broader 226 to 258 TH/s binning range per Blockspace Media launch coverage, with power draw between 3,140W and 3,500W in upper bin configuration. Positioned between the top bin M70S+ (244 to 280 TH/s at 12.5 J/TH) and base M70 (214 to 236 TH/s at 14.5 J/TH) across an identical 430 x 155 x 226 mm chassis. Runs on 220 to 240V single phase power available in most commercial and dedicated residential settings, with no three phase infrastructure required. Most compact chassis in the M70 generation at 13.5 kg. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.
Temporarily Unavailable
This product is temporarily unavailable.
Notify Me
Be the first to know when this miner becomes available.
We'll notify you when it's available!
Opravdový
Otestovaný hardware
Celosvětově
Celosvětová doprava
Podpora
Odborníci na těžbu
Těžební výkon
226 TH/s
Výkon
3140 W
Účinnost
13.89 J/TH
Hluk
75 dB
Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.
| Období | Denně | Týdenní | Měsíční |
|---|---|---|---|
|
Příjmy
|
$8.45 | $59.15 | $253.50 |
|
Elektrická energie
|
-$6.03 | -$42.21 | -$180.90 |
|
Zisk
|
$2.43 | $17.01 | $72.90 |
Using 0.080 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.
Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.
Connect PSU to miner and plug into the outlet
Připojte ethernetový kabel k vašemu routeru nebo switchi
Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP
Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit
Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.
Middle of the M70 silicon binning distribution. Better efficiency than base M70 at smaller premium than top bin M70S+ commands.
MillionMiner rated at 13.89 J/TH floor. Blockspace Media and Zeus Mining document 13.5 J/TH across the 226 to 258 TH/s binning range.
Standard commercial circuits, no three phase, no transformers, no electrical upgrades. Most compact M70 chassis at 13.5 kg.
Tell us what you need and our team will send you a customized ASIC miner hosting quote
Tell us your miner model (or quantity), your target electricity rate, and we will send a hosting cost breakdown within 24 hours.
The M70S produces 226 TH/s of SHA-256 hashrate at 3,140W and 13.89 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Blockspace Media, Zeus Mining, and Hashrate Index document the broader binning range at 226 to 258 TH/s with 13.5 J/TH efficiency and power scaling to 3,500W in upper bin configuration. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output depends on batch binning, ambient temperature, and operating conditions.
Same 3,140W rated power draw across all three variants. Same 430 x 155 x 226 mm chassis, same 13.5 kg weight, same 220 to 240V single phase requirements. Hashrate and efficiency differences come from chip binning. M70 base: 214 to 236 TH/s at 14.5 J/TH. M70S mid (this product): 226 to 258 TH/s at 13.5 J/TH. M70S+ top: 244 to 280 TH/s at 12.5 J/TH. Mid bin delivers 6 percent more hashrate than base at 7 percent better efficiency, at smaller price premium than top bin commands.
Acquisition cost to performance ratio. Mid bin silicon captures the largest volume of natural chip production distribution, which typically translates to the best acquisition cost per TH/s in any product lineup. Top bin silicon commands the price premium matching its 12.5 J/TH efficiency peak. If the per unit price gap between M70S and M70S+ is less than $250 at your supplier, the M70S+ typically wins on total lifetime economics at $0.06 per kWh industrial rates over 3 year deployments. At larger price gaps, the M70S value proposition strengthens. Run the math with your specific supplier pricing.
220 to 240V single phase commercial or residential power through a C19 power cable connection. At 240V: approximately 13 amps continuous draw at 3,140W rated mode, or 15 amps at 3,500W upper bin mode. Fits within standard 20 amp circuits with headroom. Works on European Schuko outlets (230V), UK BS 1363 (230V with rated adapters), and most international 220 to 240V infrastructure. In North America: requires 240V NEMA 6 or NEMA L6 outlets, available in commercial settings and accessible through dedicated residential circuits. Does not require three phase power, step up transformers, or specialized electrical upgrades.
Yes, with appropriate infrastructure and noise tolerance. Requirements: dedicated 220 to 240V 20 amp circuit, dedicated mining space separate from living areas due to 75 dB noise output, adequate ventilation to dissipate 3.1 kW continuous thermal load (approximately 10,700 BTU per hour). Deploy in garages, basements with sound insulation, outbuildings, or dedicated mining rooms. Not suitable for living spaces, bedrooms, home offices, or shared environments without industrial grade sound insulation.
At MillionMiner's $0.08 per kWh onsite calculator: $7.37 daily revenue, $6.03 electricity, $1.34 net profit per day. At $0.07 per kWh industrial rates: $5.28 daily electricity, netting $2 daily. At $0.04 per kWh negotiated industrial rates: $3.01 daily electricity, netting $4 daily profit per unit. Upper bin M70S output at 258 TH/s improves daily revenue 14 percent over the 226 TH/s floor rate. Home deployments at $0.10 per kWh typically run marginal or negative when accounting for hardware depreciation.
Jakákoli kryptoměna založená na SHA-256 proof of work. Bitcoin (BTC) je hlavním cílem. Další kompatibilní mince zahrnují Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB) a DigiByte (DGB SHA-256 řetězec). Sloučené těžení BTC spolu s BCH a BSV prostřednictvím podporujících poolů, jako jsou ViaBTC a F2Pool, přidává marginální sekundární příjmy bez snížení příspěvku na hash rate Bitcoinu.
Yes. All three M70 variants share identical chassis, power requirements, and Whatsminer firmware. Mix bins freely within fleets based on acquisition cost optimization and deployment strategy. Common pattern: majority M70S units for value, some M70S+ units where efficiency matters most, some M70 base units where budget is tightest. Fleet management handles mixed bin deployments transparently through unified Whatsminer firmware dashboards.
Residential or small commercial setup. Step one: verify 220 to 240V circuit with 20 amp capacity. Step two: ensure adequate ventilation in deployment space. Step three: connect PSU to outlet using the included C19 power cable. Step four: connect Ethernet cable to router or switch. Step five: power on, find miner IP through router DHCP client list or IP scanner tool, open web interface, configure pool URL and Bitcoin wallet, verify hashrate reaches 219+ TH/s within 10 to 15 minutes.
75 dB is standard industrial ASIC noise, comparable to a vacuum cleaner at close range. Not suitable for residential living spaces, bedrooms, home offices, or shared office environments. Appropriate deployment locations include dedicated mining rooms, garages with proper ventilation, basements with sound insulation, outbuildings or sheds, shipping container installations, warehouse mining operations, and professional hosting facilities. Sound insulation boxes marketed for ASIC deployment can reduce noise by 15 to 20 dB but require attention to thermal management.
3,140W per unit produces roughly 10,700 BTU of heat per hour. A 10 unit deployment generates 31.4 kW of continuous heat requiring exhaust ventilation sized to the load. Ventilation design should target at least 3 to 5 complete air changes per hour in typical deployment spaces, with exhaust capacity scaled to total fleet thermal output plus 25 to 30 percent margin for hot weather operation. Dedicated mining spaces typically use exhaust fans rated 600 to 1,500 CFM depending on fleet size.
Standard air cooled ASIC maintenance. Monthly fan cleaning with compressed air to clear dust buildup. Quarterly hashboard connector inspection. Semi annual firmware updates when MicroBT releases patches. Continuous ambient temperature monitoring to keep the unit within the 5 to 45 degree Celsius operating range. Every 18 to 24 months at full duty cycle, expect at least one fan replacement per unit due to bearing wear. Budget 3 to 5 percent of acquisition cost annually for replacement fans and parts.
Any Stratum compatible Bitcoin pool. Foundry USA leads by network share with competitive FPPS payouts. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts reducing daily variance. For mid sized commercial fleets above 2.3 PH/s (equivalent to 10+ M70S units), negotiated pool fees below standard 1 to 2 percent are typically available.
A standard 100 amp subpanel at 240V supports approximately 7 M70S units at rated 3,140W producing 1,582 TH/s aggregate. A 200 amp commercial service supports approximately 14 M70S units producing 3,164 TH/s aggregate. For dedicated mining facilities with three phase to single phase branch circuits, larger deployments become practical. Compact 13.5 kg chassis allows shelf or rack placement optimizing unit count per physical area.
M70S: 226 to 258 TH/s at 3,140 to 3,500W and 13.5 J/TH headline on 220 to 240V single phase. Antminer S21+: 235 TH/s at 3,876W and 16.5 J/TH on 200 to 277V single phase. The M70S leads meaningfully on efficiency at 13.5 J/TH versus the S21+ at 16.5 J/TH. The S21+ leads on absolute hashrate per unit at 235 TH/s versus 226 TH/s at the M70S floor. At upper bin M70S output of 258 TH/s, the M70S wins on both metrics. For operators optimizing efficiency, the M70S is the better choice at this hashrate class.
M70S: 226 to 258 TH/s at 13.5 J/TH headline on 220 to 240V single phase. Antminer S21: 200 TH/s at 3,500W and 17.5 J/TH on 200 to 277V. The M70S leads on both hashrate and efficiency. For operators prioritizing efficiency at the 3 to 3.5 kW air cooled power class, the M70S is the stronger choice over the older S21. The newer Bitmain Antminer S23 generation at 10 J/TH liquid cooled provides a different positioning entirely.
MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from inadequate cooling or ventilation, operation outside the 5 to 45 degree Celsius range, power surge damage from inadequate electrical protection, physical mishandling, and unauthorized firmware modifications. MillionMiner routes warranty claims through direct MicroBT channels for faster resolution than secondary market purchases provide.
Yes. MillionMiner operates managed hosting facilities with 220 to 240V single phase service and ventilation infrastructure capable of supporting M70S deployments. Hosted deployment eliminates facility infrastructure CapEx for operators preferring turnkey air cooled deployment. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.
Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M70S units automatically through network scanning. Mixed brand fleets (MicroBT alongside Bitmain, Bitdeer, or Canaan hardware) handle through unified dashboards with brand specific monitoring metrics where applicable. Mixed cooling type fleets (M70S air alongside M79S immersion or M73 hydro) manage through the same Whatsminer interface with cooling specific monitoring metrics appearing where applicable.
Within MicroBT's M70 standard voltage air cooled tier: the M70S+ at 244 to 280 TH/s is the top bin upgrade path, and M70 at 214 to 236 TH/s is the base bin alternative for volume fleet buyers. Cross family at MicroBT: M72 and M72S cover the 4 kW industrial voltage air tier on three phase, M76 series covers the 5.2 kW immersion tier, M73 series covers rack mount hydro, M78 and M79 series cover higher power liquid cooling tiers. Cross brand single phase alternatives: the Antminer S21+ at 235 TH/s and 16.5 J/TH, Antminer S21 XP at 270 TH/s and 13.5 J/TH, Canaan Avalon A16XP at 12.8 J/TH provide vendor diversification. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining on separate infrastructure. MillionMiner's ASIC hosting service accepts M70S units at negotiated industrial electricity rates.