Vyprodáno

MicroBT

MicroBT Whatsminer M72S 264TH

Model: Whatsminer M72S

Nový

264 TH/s air cooled SHA-256 Bitcoin miner at 4,000W and 15.15 J/TH efficiency in rated mode, built on MicroBT's 5nm chip architecture. The top bin in the M70 generation's industrial voltage air cooled tier. Overclock mode reaches up to 300 TH/s at 6,000W with 13.5 J/TH efficiency per Zeus Mining and distributor specifications. Targets facilities with 380 to 480V three phase industrial power that have chosen not to invest in liquid cooling infrastructure. 25 M72S units fit per 100 kW panel producing 6,600 TH/s aggregate fleet hashrate. 367 x 200 x 296 mm at 25.5 kg. 75 dB four fan air cooling. Currently out of stock. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

264 TH/s 4000W SHA-256 15.15 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

264 TH/s

Výkon

4000 W

Účinnost

15.15 J/TH

Hluk

75 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$9.87 $69.09 $296.10
Elektrická energie
-$7.68 -$53.76 -$230.40
Zisk
$2.19 $15.33 $65.70

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 264 TH/s
Spotřeba energie 4000 W
Účinnost 15.15 J/TH
Algoritmus SHA-256
Model Whatsminer M72S
Rok vydání Prosince 2025
Hladina hluku 75 dB
Rozměry 367 x 200 x 296mm
Váha 25.5 kg
Napětí AC 380-480V
Rozhraní Ethernet
Provozní teplota 0 - 40 °C
vlhkost 5 - 95 %
Typ chlazení Air

Co je v krabici

Whatsminer M72S
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Detaily produktu

MicroBT Whatsminer M72S 264 TH/s Air Cooled Bitcoin Miner: Specifications, Deployment Economics, and Industrial Infrastructure Guide

The Whatsminer M72S occupies a specific strategic niche in MicroBT's M70 generation: air cooled simplicity combined with industrial voltage power. Most air cooled Bitcoin miners run on 200 to 277V single phase power (like standard Antminer S21 series or the M70 and M70S entry tier units). The M72S requires 380 to 480V three phase service, which means it targets facilities with industrial electrical infrastructure that have chosen not to invest in liquid cooling. Why would a facility with three phase power skip immersion or hydro? Capital cost. Immersion tanks, dielectric fluid, heat exchangers, pumps, and plumbing add substantial upfront investment per unit deployed. Air cooled miners need power and ventilation only. For operations running shipping container deployments, warehouse mining rooms, or industrial spaces with three phase service and adequate natural airflow, the M72S avoids the liquid infrastructure cost entirely while retaining industrial electrical service. Rated mode specifications: 264 TH/s SHA-256 hashrate at 4,000W and 15.15 J/TH efficiency. Built on MicroBT's 5nm chip architecture. Industry sources including Zeus Mining and Apexto document an overclock mode reaching up to 300 TH/s at 6,000W and 13.5 J/TH efficiency. Operators can run the M72S at rated specifications for stability or push into overclock mode when electricity pricing and cooling capacity support the higher output. Fleet deployment math favors the M72S's power envelope for facilities scaling up air cooled capacity. A 100 kW electrical panel supports 25 M72S units in rated mode producing 6,600 TH/s aggregate hashrate. The same 100 kW panel supports 7 M79 hydro units at 6,440 TH/s, or 14 M78 immersion units at 6,160 TH/s. Similar total output across the three approaches but with dramatically different infrastructure CapEx. Air cooling eliminates tank, fluid, CDU, and heat exchanger investment entirely, trading that capital savings for higher ongoing electrical cost per terahash (15.15 J/TH versus 14.83 J/TH on immersion). Common deployment scenarios for the M72S include shipping container mining installations with three phase power feeds and exhaust fan ventilation, warehouse mining rooms with industrial electrical service and high ceiling airflow, and facility expansion zones added to existing operations without matching liquid cooling capacity. Container deployments in particular suit the M72S because the 380 to 480V three phase requirement matches standard industrial container electrical specifications while air cooling avoids the complications of running fluid infrastructure in transport modular facilities. Physical specifications: 367 x 200 x 296 mm at 25.5 kg. Four fan air cooling produces 75 dB operating noise standard for industrial ASIC hardware. Not suitable for residential or shared commercial environments. Ethernet 10/100M management through standard Whatsminer firmware with Foreman, Awesome Miner, Hive OS compatibility. 0 to 40 degrees Celsius operating range covers most climates outside extreme cold. 5 to 95 percent humidity tolerance. Bitcoin mining economics at the M72S power class depend on electricity rate. At MillionMiner's $0.08 per kWh onsite calculator: $8.64 daily revenue, $7.68 electricity, $0.96 net profit per day. Margins are tight at standard rates. At $0.04 per kWh industrial negotiated rates: daily electricity drops to $3.84, netting $4 to $5 daily profit per unit. Residential electricity above $0.10 per kWh makes the M72S unprofitable at current difficulty. Industrial facility deployment with negotiated power rates is required for sustained profitability. Currently out of stock at MillionMiner. Ships with PSU, 360 day MicroBT manufacturer warranty, and free DDP delivery worldwide when available.

MicroBT Whatsminer M72S 264 TH/s: Air Cooled Industrial Mining Without

The M72S occupies a specific strategic position in MicroBT's M70 lineup.
Most air cooled Bitcoin miners run on 200 to 277V single phase (like standard M70 units or
Antminer S21 series). The M72S requires 380 to 480V three phase, targeting facilities with
industrial electrical infrastructure that have chosen not to invest in liquid cooling tanks, fluid,
pumps, or heat exchangers.
The deployment case is straightforward. Warehouse and container operations with three phase
power feeds and exhaust ventilation avoid the substantial capital cost of immersion
infrastructure while still operating on industrial electrical service. A 100 kW panel supports 25
M72S units producing 6,600 TH/s aggregate versus 14 hydro M79 units also producing around
6,510 TH/s. Similar total hashrate, but the M72S fleet avoids CDU, plumbing, and cooling loop
investment entirely.
Rated mode: 264 TH/s at 4,000W and 15.15 J/TH efficiency on 5nm chip architecture.
Overclock mode: up to 300 TH/s at 6,000W and 13.5 J/TH per distributor specifications. 0 to 40
degrees Celsius operating range covers most climates outside extreme cold. Currently out of
stock. Ships with 360 day MicroBT warranty and free DDP worldwide.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Whatsminer M72S 264 TH/s Air Cooled Bitcoin Miner

Air cooled simplicity on industrial voltage. The M72S is MicroBT's top bin in
the M70 generation's air cooled industrial tier, targeting facilities with 380 to 480V three phase
power that have chosen warehouse ventilation over immersion or hydro infrastructure
investment. 264 TH/s at 4,000W and 15.15 J/TH in rated mode on 5nm silicon. Overclock mode
at 6,000W reaches up to 300 TH/s and 13.5 J/TH efficiency per Zeus Mining specifications. A
100 kW panel supports 25 M72S units producing 6,600 TH/s aggregate fleet hashrate. Zero
liquid infrastructure commitment, container and warehouse deployment friendly with good
airflow. 367 x 200 x 296 mm at 25.5 kg. 75 dB four fan cooling. Currently out of stock at
MillionMiner.

264 TH/s Air Cooled on Industrial Voltage

Top bin in the 4 kW air cooled tier. 380 to 480V three phase power without liquid cooling infrastructure. 5nm chip architecture.

Rated 15.15 J/TH, Overclock 13.5 J/TH

Normal mode at 264 TH/s and 4,000W. Overclock mode reaches 300 TH/s at 6,000W with better efficiency per Zeus Mining specifications.

25 Units per 100 kW Panel

Fleet math: 25 M72S units produce 6,600 TH/s on 100 kW without tank, fluid, or CDU investment. Capital efficient air cooled scaling.

Request a Bitcoin Miner Hosting Quote

4.7
hvězda hvězda hvězda hvězda hvězda

4.7/5 Verified on Trustpilot

  • obálka 30,000+ miners hosted since 2020
  • časovač Trusted by 1,200+ customers globally
iso vyrobeno v Německu Trustpilot
hodnocení-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

horník

Těžební pracovník

hostování

Hostování

Často kladené dotazy

Nejčastější otázky

The M72S produces 264 TH/s of SHA-256 hashrate at 4,000W and 15.15 J/TH efficiency in the rated operating mode, built on MicroBT's 5nm chip architecture. Zeus Mining and distributor specifications document an overclock mode reaching up to 300 TH/s at 6,000W and 13.5 J/TH efficiency when facility conditions support higher output. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world rated mode output typically falls between 256 and 272 TH/s.

Capital cost avoidance. Immersion tanks, dielectric fluid, heat exchangers, pumps, plumbing, and CDU infrastructure add $10,000 to $40,000+ per rack of liquid cooling investment. The M72S operates on air cooling only, requiring power and ventilation but zero liquid infrastructure. For operators running shipping container mining, warehouse operations with industrial electrical service, or expansion zones into facilities without matching liquid cooling capacity, the M72S delivers comparable total fleet hashrate at dramatically lower facility CapEx. Tradeoff: higher ongoing electricity cost per terahash (15.15 J/TH air versus 14.83 J/TH immersion or 9.5 J/TH hydro on competing products).

Target market positioning. MicroBT designed the M72S specifically for facilities with existing industrial electrical infrastructure. Most air cooled Bitcoin miners (standard M70, Antminer S21 series) run on 200 to 277V single phase to serve home and small commercial deployments. The M72S targets industrial facility operators who have three phase service but have chosen not to invest in liquid cooling, providing a product that fits their existing electrical infrastructure without requiring step down transformers or single phase circuits.

Podle uvedených specifikací společnosti MillionMiner vyžaduje M72S třífázové napájení s napětím od 380 do 480 V. Jingle Mining uvádí „podporu globálního napětí“, což naznačuje, že některé varianty mohou akceptovat různé napěťové konfigurace, ale primární nasazení je v průmyslové třífázové síti. Před koupí si ověřte vaše napěťové specifikace série s prodejem MillionMiner, pokud plánujete jednofázové nasazení. Pro jednofázové domácí nebo komerční operace je vhodnější produkt Antminer S21+ s výkonem 235 TH/s a napětím 220 až 277 V.

A 100 kW electrical panel supports 25 M72S units in rated mode producing 6,600 TH/s aggregate hashrate. Alternative panel sizes scale linearly: 50 kW supports 12 M72S units at 3,168 TH/s, 200 kW supports 50 M72S units at 13,200 TH/s. Compare these air cooled deployments against M78 immersion options (14 M78 units per 100 kW producing 6,160 TH/s) or M79 hydro options (7 M79 units per 100 kW producing 6,440 TH/s) before committing to facility architecture. Air cooling eliminates liquid infrastructure CapEx but accepts lower efficiency per terahash.

At MillionMiner's $0.08 per kWh onsite calculator: $8.64 daily revenue, $7.68 electricity, $0.96 net profit per day. Margins are tight at standard rates. At $0.07 per kWh industrial rates: approximately $6.72 daily electricity, netting $2 daily. At $0.04 per kWh negotiated industrial rates: $3.84 daily electricity, netting $4 to $5 daily profit per unit. Residential electricity above $0.10 per kWh makes the M72S unprofitable at current difficulty. Industrial facility deployment with negotiated power rates is required.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target and largest SHA-256 network. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), and DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools like ViaBTC and F2Pool adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

No. The M72S requires 380 to 480V three phase industrial power unavailable in residential settings, and produces 75 dB operating noise unsuitable for home environments. Home mining hardware operates on 200 to 277V single phase circuits available through dryer or stove outlets. For high hashrate home deployment on single phase power, the Antminer S21+ at 235 TH/s and Antminer S21 XP at 270 TH/s are appropriate product matches. The M72S is strictly industrial hardware for commercial and warehouse facilities.

75 dB is standard industrial ASIC noise, comparable to a vacuum cleaner at close range. Not suitable for residential living spaces, bedrooms, home offices, or shared office environments. Appropriate deployment locations include dedicated mining rooms, shipping container installations, warehouse mining operations, industrial facilities, outbuildings with ventilation, and professional hosting facilities. Standard industrial hearing protection is recommended when working near the hardware for extended periods.

The Whatsminer M72 (standard bin) produces 246 TH/s at 4,000W and 14.5 J/TH per X ON Mining and Apexto specifications. Same chassis, same power, same 380 to 480V three phase requirements. 7 percent less hashrate at lower per unit acquisition cost. Volume fleet buyers prioritizing unit count over efficiency favor the M72. Operators with higher electricity rates or longer deployment horizons favor the M72S because efficiency savings compound daily. Mix M72 and M72S units freely in the same fleet based on per unit economics at your rate.

Industrial deployment with three phase power and air cooled ventilation. Step one: install three phase 380 to 480V electrical service with appropriate breakers for 4 kW continuous draw per unit (approximately 10 amps per phase at 415V, or 9 amps at 480V). Step two: prepare adequate ventilation in deployment space (exhaust fans, intake airflow, appropriate temperature management). Step three: rack or position M72S units with clear airflow paths. Step four: connect PSU power and Ethernet management. Step five: power on, find each miner IP through DHCP, configure pool URL and Bitcoin wallet through the Whatsminer web interface, verify hashrate reaches 256+ TH/s within 10 to 15 minutes per unit.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share with competitive FPPS payouts. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts reducing daily variance. For fleet deployments above 2.6 PH/s (equivalent to 10+ M72S units), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates.

Yes. Zeus Mining and Apexto specifications document an overclock mode reaching up to 300 TH/s at 6,000W and 13.5 J/TH efficiency. The overclock mode trades 50 percent higher power draw for roughly 14 percent more hashrate with improved efficiency per terahash. Use overclock mode when electricity pricing supports the higher output and cooling capacity tolerates the additional 2 kW thermal load per unit. Rated 4,000W mode is typically more stable for sustained 24/7 operation and reduces hardware stress compared to continuous overclock operation.

Standard air cooled ASIC maintenance. Monthly fan cleaning with compressed air to clear dust buildup. Quarterly hashboard connector inspection. Semi annual firmware updates when MicroBT releases patches. Continuous ambient temperature monitoring to keep the unit within the 0 to 40 degree Celsius operating range. Every 18 to 24 months at full duty cycle, expect at least one fan replacement per unit due to bearing wear. Budget 3 to 5 percent of acquisition cost annually for replacement fans and parts.

Yes. MillionMiner operates managed hosting facilities with three phase industrial power and ventilation infrastructure capable of supporting M72S deployments. Hosted deployment eliminates facility infrastructure CapEx for operators who prefer turnkey air cooled deployment. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from inadequate cooling or ventilation, operation outside the 0 to 40 degree Celsius range, power surge damage from inadequate electrical protection, physical mishandling, and unauthorized firmware modifications. MillionMiner routes warranty claims through direct MicroBT channels for faster resolution than secondary market purchases provide.

Currently out of stock. Use the Notify Me button on the MillionMiner product page for email alerts when new inventory arrives. Use the Get a Quote button to contact MillionMiner sales directly for estimated restock timing and priority reservation on incoming batches. M72S hardware moves quickly when batches arrive because the industrial air cooled segment is concentrated among commercial facility operators with standing orders.

Different target markets. Antminer S21 XP: 270 TH/s at 3,645W and 13.5 J/TH on 200 to 277V single phase. M72S: 264 TH/s at 4,000W and 15.15 J/TH on 380 to 480V three phase. The S21 XP delivers slightly more hashrate at better efficiency on standard single phase power, making it more accessible for home, small commercial, and mid scale deployments. The M72S targets industrial facilities with existing three phase infrastructure that prefer MicroBT ecosystem integration. For single phase residential or commercial operations, the S21 XP is the better choice. For industrial three phase fleets standardizing on MicroBT firmware, the M72S fits the ecosystem.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M72S units automatically through network scanning. Mixed brand fleets (MicroBT alongside Bitmain, Bitdeer, or Canaan hardware) handle through unified dashboards with brand specific monitoring metrics where applicable.

Within MicroBT's air cooled lineup: the M72 at 246 TH/s provides the M72S's standard bin sibling for volume fleet deployment, and M70 and M70S at 214 to 226 TH/s cover lower power tier air cooled deployment. Cross family at MicroBT: hydro variants M73S, M76 hydro, M79, M79S provide liquid cooling upgrade paths, and immersion variants M76 and M78 series provide alternative liquid approach. Cross brand single phase options: the Antminer S21+ at 235 TH/s and Antminer S21 XP at 270 TH/s cover mid scale single phase deployment at better efficiency. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining on separate infrastructure. MillionMiner's ASIC hosting service accepts M72S units at negotiated industrial electricity rates.

Get a Quote