500 TH/s hydro cooled SHA-256 Bitcoin miner at 7,200W and 14.4 J/TH efficiency, the mid bin of MicroBT's M73 rack mount hydro tier in the M70 generation. Manufacturer headline spec runs 13.5 J/TH across the broader 500 to 540 TH/s binning range per Apexto and Zeus Mining. Positioned between the top bin M73S+ (540 to 600 TH/s at 12.5 J/TH) and base M73 (470 to 500 TH/s at 14.5 J/TH) across an identical 4U rack mount chassis. Closed loop water cooling in standard 19 inch server racks avoids the specialized dielectric fluid and custom tank infrastructure of immersion approaches. 10 M73S units per 42U rack produce 5 PH/s at 72 kW. 483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase industrial power. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

500 TH/s 7200W SHA-256 14.4 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Opravdový

Otestovaný hardware

Celosvětově

Celosvětová doprava

Podpora

Odborníci na těžbu

Těžební výkon

500 TH/s

Výkon

7200 W

Účinnost

14.40 J/TH

Hluk

75 dB

Odhadované výnosy z těžby

Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.

Období Denně Týdenní Měsíční
Příjmy
$19.38 $135.66 $581.40
Elektrická energie
-$8.64 -$60.48 -$259.20
Zisk
$10.74 $75.18 $322.20

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.

Kompletní specifikace

Těžební výkon 500 TH/s
Spotřeba energie 7200 W
Účinnost 14.40 J/TH
Algoritmus SHA-256
Model Whatsminer M73S
Rok vydání Prosince 2025
Hladina hluku 75 dB
Rozměry 483 x 663 x 86mm
Váha 29.5 kg
Napětí AC 380-480V
Rozhraní Ethernet
Provozní teplota 5 - 45 °C
vlhkost 5 - 95 %
Typ chlazení Hydro
Formát stojanu 4U

Co je v krabici

Whatsminer M73S
Zdroj napájení (PSU)
Napájecí kabely
Rychlý průvodce začátkem

Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.

Rychlá instalace

1

Connect PSU to miner and plug into the outlet

2

Připojte ethernetový kabel k vašemu routeru nebo switchi

3

Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP

4

Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
hvězda hvězda hvězda hvězda hvězda

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso vyrobeno v Německu Trustpilot
hodnocení-google

Get a Quote for the MicroBT Whatsminer M73S 500TH

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Detaily produktu

MicroBT Whatsminer M73S 500 TH/s Hydro Cooled 4U Rack Mount Bitcoin Miner: Mid Bin Specifications and Deployment Guide

The Whatsminer M73S sits in the middle of MicroBT's M73 rack mount
hydro tier, positioned between the top bin M73S+ (540 to 600 TH/s at 12.5 J/TH) and base M73
(470 to 500 TH/s at 14.5 J/TH). All three M73 variants share identical 4U rack mount chassis,
7,200W rated power envelope, water cooling architecture, and 380 to 480V three phase
requirements. Chip binning grade differentiates them.
MillionMiner rated spec: 500 TH/s at 7,200W and 14.4 J/TH efficiency. Manufacturer headline
specs per Apexto, Zeus Mining, and X ON Mining document the broader binning range at 500 to
540 TH/s with 13.5 J/TH efficiency across the platform. MicroBT rates the unit at plus or minus 3
percent hashrate tolerance. Real world output varies with batch binning, coolant temperature,
and operating conditions.
Mid bin economics favor the M73S for operators wanting the strongest acquisition cost to
performance ratio in the M73 hydro lineup. Chip binning produces natural performance
distribution from silicon fabrication, and mid bin captures the largest volume of that distribution.
Top bin silicon (M73S+) charges the price premium that matches its 12.5 J/TH efficiency peak.
Base bin silicon (M73) sells at the floor for volume fleet buyers maximizing unit count per capital
dollar. Mid bin sits between, meaningfully better efficiency than base grade at smaller price
premium than top grade commands.
The efficiency comparison is quantifiable. M73S at 14.4 J/TH (MillionMiner rated) or 13.5 J/TH
(manufacturer headline) versus M73S+ at 13.33 J/TH or 12.5 J/TH. At $0.04 per kWh industrial
rates, the per unit daily electricity difference runs $0.15 to $0.20. At $0.08 per kWh: $0.30 to
$0.40 daily per unit. Across a 10 unit rack, those differences compound to $3 to $4 daily.
Whether that gap justifies the M73S+ price premium depends on deployment horizon and
electricity rate.
Rack mount hydro approach differs from immersion fundamentally. The M73S does not
submerge in fluid. Water flows through internal channels in a sealed 4U chassis and carries
heat to an external cooling loop. Units install in standard 19 inch server racks alongside any
other data center equipment. No immersion tanks, no dielectric fluid, no custom tank
infrastructure. Standard water glycol coolant, off the shelf pumps, standard plumbing.
For data center operators familiar with water cooled server infrastructure, the M73 series
deploys without the learning curve and capital cost of immersion. Standard racks, standard
water connections, familiar maintenance procedures. The 4U form factor drops into the same 19
inch cabinets used for servers, switches, and other data center equipment. For operators
expanding from compute or storage into mining, the M73 series uses infrastructure they already
own and understand.
Fleet deployment math: 10 M73S units per 42U rack produce 5 PH/s at 72 kW per rack. The
M73S+ rack produces 5.4 PH/s at the same 72 kW. The M73 rack produces 4.7 PH/s. Mix bins
within racks based on acquisition cost optimization.
Bitcoin mining economics: MillionMiner's $0.08 per kWh onsite calculator shows $16.33 daily
revenue, $13.82 electricity, $2.51 net profit per day. At $0.04 per kWh industrial rates: $6.91
daily electricity, netting $9 to $10 daily per unit. A 10 unit M73S rack produces $90 to $100 daily
net profit at $0.04 per kWh.
483 x 663 x 86 mm at 29.5 kg. Ethernet 10/100M management through standard Whatsminer
firmware with Foreman, Awesome Miner, Hive OS compatibility. 5 to 45 degrees Celsius
operating range at 5 to 95 percent humidity. PSU ships included. 360 day MicroBT manufacturer
warranty. Free DDP delivery worldwide from MillionMiner.

MicroBT Whatsminer M73S 500 TH/s: Mid Bin Value in the M73 Hydro Rack

The M73S occupies the sweet spot in the M73 hydro lineup. Same
7,200W power draw as the M73S+ and M73, same 4U rack mount chassis, same water cooling
architecture, same 380 to 480V three phase requirements. Chip binning grade and
correspondingly different acquisition cost per unit differentiates the variants.
MillionMiner rated spec: 500 TH/s and 14.4 J/TH. Manufacturer headline per Apexto and Zeus
Mining: 500 to 540 TH/s across the binning range at 13.5 J/TH efficiency. Real world output
depends on batch binning.
Mid bin typically delivers the best acquisition cost to performance ratio because it captures the
largest volume of the natural production distribution. Top bin silicon (M73S+) commands the
price premium that matches its 12.5 J/TH peak efficiency. Base bin silicon (M73) sells at the
floor for maximum unit count per hardware budget. Mid bin sits between, meaningfully better
efficiency than base grade at smaller price premium than top grade commands.
Rack mount hydro approach uses water cooling through sealed internal channels in the 4U
chassis. Deploys into standard 19 inch server racks alongside other data center equipment,
avoiding the specialized dielectric fluid and custom tank infrastructure of immersion. Water
cooling uses off the shelf pumps, standard plumbing, and water glycol coolant. 10 units per 42U
rack produce 5 PH/s at 72 kW.

Potřebujete pomoc s výběrem?

Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.

Whatsminer M73S 500 TH/s Hydro 4U Bitcoin Miner

Mid bin of MicroBT's M73 rack mount hydro tier, positioned between the top
bin M73S+ (540 to 600 TH/s at 12.5 J/TH) and base M73 (470 to 500 TH/s at 14.5 J/TH).
MillionMiner rated spec: 500 TH/s at 7,200W and 14.4 J/TH. Manufacturer headline at 13.5 J/TH
across the 500 to 540 TH/s binning range per Apexto and Zeus Mining. Mid bin typically offers
the strongest acquisition cost to performance ratio in any chip lineup. Closed loop water cooling
in a 4U chassis for standard 19 inch server racks, avoiding the specialized dielectric fluid and
custom tank infrastructure of immersion approaches. 10 units per 42U rack produce 5 PH/s at
72 kW. 483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase. Ships from MillionMiner with
360 day warranty and free DDP worldwide.

500 TH/s Mid Bin Value Pick

Middle of the M73 silicon binning distribution. Better efficiency than base M73 at smaller premium than top bin M73S+ commands.

13.5 J/TH Manufacturer Headline

MillionMiner rated at 14.4 J/TH floor. Apexto and Zeus Mining document 13.5 J/TH across the 500 to 540 TH/s binning range.

Standard 4U Rack Mount, Water Cooled

Sealed 4U chassis for 19 inch server racks. Water lines, not immersion tanks. Integrates into existing liquid cooled data center infrastructure.

Často kladené dotazy

Nejčastější otázky

The M73S produces 500 TH/s of SHA-256 hashrate at 7,200W and 14.4 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Apexto, Zeus Mining, and X ON Mining document the broader binning range at 500 to 540 TH/s with 13.5 J/TH efficiency. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output depends on batch binning, coolant temperature, and operating conditions.

Same 7,200W rated power draw across all three variants. Same 4U chassis, same water cooling architecture, same 380 to 480V three phase requirements. Hashrate and efficiency differences come from chip binning. M73 base: 470 to 500 TH/s at 14.5 J/TH. M73S mid (this product): 500 to 540 TH/s at 13.5 J/TH. M73S+ top: 540 to 600 TH/s at 12.5 J/TH. Mid bin delivers 6 to 8 percent more hashrate than base at roughly 7 percent better efficiency, at smaller price premium than top bin commands.

Acquisition cost to performance ratio. Mid bin silicon captures the largest volume of the natural chip production distribution, which typically translates to the best acquisition cost per TH/s in any product lineup. Top bin silicon commands the price premium that matches its 12.5 J/TH efficiency peak. If the per unit price gap between M73S and M73S+ is less than $400 at your supplier, the M73S+ typically wins on total lifetime economics at $0.06 per kWh industrial rates over 3 year deployments. At larger price gaps, the M73S value proposition strengthens. Run the math with your specific supplier pricing.

Hydro cooling uses closed loop water circulation through internal channels in a sealed 4U chassis. The M73S does not submerge in fluid. Water absorbs heat inside the chassis and carries it to an external cooling loop through standard plumbing. Units install in 19 inch server racks alongside other data center equipment. Immersion cooling submerges the entire miner in dielectric fluid held in specialized tanks. The M73S hydro approach uses off the shelf pumps, standard plumbing, and common water glycol coolant. Immersion requires specialized dielectric fluid at higher cost per liter and custom tank infrastructure.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 17 amps per phase at 7,200W continuous draw. At 480V three phase: approximately 15 amps per phase. Fits within standard 20 amp commercial breakers with headroom. Same three phase requirements as the entire M73 series and other MicroBT M70 hydro variants, so facilities designed for one M73 variant support all others without electrical modifications.

Closed loop water circulation with off the shelf components. Required: circulation pumps sized for total fleet flow rate, standard plumbing fittings, water glycol coolant mixture, external heat rejection through dry coolers or water to water heat exchangers, and inline filtration. Coolant volume scales roughly 2 to 4 liters per unit plus system reservoir capacity. Each M73S adds approximately 24,570 BTU per hour of thermal load. Uses standard data center cooling equipment available from any industrial supplier.

A standard 42U rack holds 10 M73S units producing 5 PH/s at 72 kW per rack. The M73S+ rack produces 5.4 PH/s, the M73 rack 4.7 PH/s at the same 72 kW. Mix bins within racks based on acquisition cost optimization. Compare against immersion alternatives (M76S+ at 19 units per 100 kW producing 7,410 TH/s in tanks) or high power hydro alternatives (M79S at 7 units per 100 kW producing 6,510 TH/s in 3U chassis). The M73S rack mount approach wins on infrastructure familiarity and standard server rack integration rather than absolute density per kilowatt.

At MillionMiner's $0.08 per kWh onsite calculator: $16.33 daily revenue, $13.82 electricity, $2.51 net profit per day. At $0.07 per kWh industrial rates: approximately $12.10 daily electricity, netting $4 to $5 daily. At $0.04 per kWh negotiated industrial rates: $6.91 daily electricity, netting $9 to $10 daily profit per unit. Upper bin M73S output at 540 TH/s improves daily revenue by 8 percent over the 500 TH/s floor rate. A 10 unit M73S rack produces $90 to $100 daily net profit at $0.04 per kWh.

Jakákoli kryptoměna založená na SHA-256 proof of work. Bitcoin (BTC) je hlavním cílem. Další kompatibilní mince zahrnují Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB) a DigiByte (DGB SHA-256 řetězec). Sloučené těžení BTC spolu s BCH a BSV prostřednictvím podporujících poolů, jako jsou ViaBTC a F2Pool, přidává marginální sekundární příjmy bez snížení příspěvku na hash rate Bitcoinu.

Yes. All three M73 variants share identical 4U chassis geometry, identical water cooling connector design, identical power requirements, and identical Whatsminer firmware. Mix bins freely within racks based on acquisition cost optimization and fleet deployment strategy. Common pattern: majority M73S units for value, some M73S+ units in slots where efficiency matters most, some M73 base units where budget is tightest. Fleet management handles mixed bin deployments transparently.

Industrial deployment with three phase power and water cooling infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission water cooling loop including pumps, plumbing, and dry coolers. Step three: rack mount M73S units in standard 19 inch racks and connect water inlet/outlet fittings. Verify zero leaks before energizing. Step four: connect PSU power and Ethernet management. Step five: power on, allow coolant flow to stabilize, find each miner IP through DHCP, configure pool URL and Bitcoin wallet through the Whatsminer web interface, verify hashrate reaches 485+ TH/s within 15 to 20 minutes per unit.

Water cooling maintenance. Weekly visual inspection of fittings for leaks or corrosion. Monthly coolant quality testing (pH within spec, particulate levels minimal). Every 12 to 24 months full coolant replacement depending on fluid chemistry. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Hashboard failure rates on hydro units run lower than air cooled because chips operate at consistent temperatures. Water cooling maintenance is simpler than immersion fluid management because water glycol is cheaper and more widely available than dielectric fluid.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts. For fleet deployments above 5 PH/s (equivalent to 10+ M73S units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

No. The M73S requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V 20A circuits. For high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document coolant testing schedule and maintenance logs to protect warranty coverage.

Yes. MillionMiner operates managed hosting facilities with three phase industrial power and water cooling infrastructure capable of supporting M73S deployments. Hosted deployment eliminates facility infrastructure CapEx. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M73S units automatically through network scanning. Additional monitoring metrics for hydro operation (coolant flow rate, inlet/outlet temperatures) appear in hydro specific dashboards. Mixed brand and cooling type fleets handle through unified dashboards.

Different scales. M73S: 500 to 540 TH/s at 7,200W and 13.5 J/TH headline in 4U chassis. Antminer S23 Hyd 3U: 1,160 TH/s at 11,020W and 9.5 J/TH in 3U chassis. Bitmain's S23 Hyd 3U leads on absolute hashrate per unit and efficiency per terahash. The M73S fits facilities wanting hydro mining at mid power tier with broader bin flexibility. For operations building dedicated petahash class deployment, the S23 Hyd 3U is the more aggressive choice. For operations integrating hydro mining into existing data center infrastructure at comfortable per unit scale, the M73S fits better.

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack depending on capacity), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 7.2 kW: electricity at $5,045 at $0.08 per kWh, $2,522 at $0.04 per kWh industrial rates, water glycol coolant maintenance ($100 to $300 per unit annually), spare parts. Water cooling infrastructure CapEx runs meaningfully lower than immersion tank systems, which is the primary economic argument for rack mount hydro over immersion deployment.

Within the M73 rack mount hydro tier: the Whatsminer M73S+ at 540 to 600 TH/s is the top bin upgrade path, and M73 at 470 to 500 TH/s is the base bin alternative for volume fleet buyers. Cross cooling at MicroBT: immersion variants M76 and M78 series cover alternative liquid cooling for facilities with tank infrastructure, M79 and M79S cover high power hydro tier. Cross brand hydro: the Bitmain Antminer S23 Hyd 3U at 1.16 PH/s provides vendor diversification at higher power tier. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining. MillionMiner's ASIC hosting service accepts M73S units at negotiated industrial electricity rates.