MicroBT
Model: Whatsminer M76S
362 TH/s immersion cooled SHA-256 Bitcoin miner at 5,200W and 14.36 J/TH efficiency, the mid bin of MicroBT's 5.2 kW immersion tier in the M70 generation. Manufacturer headline spec runs 13.5 J/TH across the broader 362 to 406 TH/s binning range documented by Apexto, Zeus Mining, and X ON Mining. Positioned between the top bin M76S+ (390 to 440 TH/s at 12.5 J/TH) and the base M76 (336 to 374 TH/s at 14.5 J/TH) across an identical 5.2 kW chassis. 19 M76S units per 100 kW panel produce 6,878 TH/s aggregate, retaining the density advantage of the lightest immersion tier. Same 267 x 147 x 401 mm chassis at 18 kg. 380 to 480V three phase. Dielectric fluid immersion. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.
Temporarily Unavailable
This product is temporarily unavailable.
Notify Me
Be the first to know when this miner becomes available.
We'll notify you when it's available!
Opravdový
Otestovaný hardware
Celosvětově
Celosvětová doprava
Podpora
Odborníci na těžbu
Těžební výkon
362 TH/s
Výkon
5200 W
Účinnost
14.36 J/TH
Hluk
75 dB
Na základě aktuální ceny BTC a obtížnosti sítě. Pouze orientační.
| Období | Denně | Týdenní | Měsíční |
|---|---|---|---|
|
Příjmy
|
$14.01 | $98.07 | $420.30 |
|
Elektrická energie
|
-$6.24 | -$43.68 | -$187.20 |
|
Zisk
|
$7.77 | $54.39 | $233.10 |
Using 0.050 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.
Obsah se může lišit podle šarže. Přesné položky jsou uvedeny v potvrzení objednávky.
Connect PSU to miner and plug into the outlet
Připojte ethernetový kabel k vašemu routeru nebo switchi
Najděte IP těžaře prostřednictvím administrace routeru nebo nástroje pro skenování IP
Otevřete webové rozhraní, zadejte URL bazénu a peněženku — začněte těžit
Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Naši baníčí specialisté vám mohou pomoci najít ideální těžař pro vaši sestavu a rozpočet.
Middle of the M76 silicon binning distribution. Meaningfully better efficiency than base M76 at smaller premium than top bin M76S+.
MillionMiner rated at 14.36 J/TH floor. Apexto and Zeus Mining document 13.5 J/TH across the 362 to 406 TH/s binning range.
Identical 267 x 147 x 401 mm chassis and tank geometry to M76S+, M76, M78, M78S. Mix bins freely across immersion tanks.
The M76S produces 362 TH/s of SHA-256 hashrate at 5,200W and 14.36 J/TH efficiency in the MillionMiner rated specification. Manufacturer headline specs per Apexto, Zeus Mining, and X ON Mining document the broader binning range at 362 to 406 TH/s and 13.5 J/TH efficiency. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output depends on batch binning, fluid temperature, and operating conditions. 13.5 J/TH places the M76S one efficiency tier below the M76S+ at 12.5 J/TH.
Same 5,200W power draw and identical chassis across all three variants. Hashrate and efficiency differences come from chip binning. M76 base: 336 to 374 TH/s at 14.5 J/TH. M76S mid: 362 to 406 TH/s at 13.5 J/TH. M76S+ top: 390 to 440 TH/s at 12.5 J/TH. Mid bin delivers 8 percent more hashrate than base at 7 percent better efficiency, at smaller price premium than top bin commands. For operators wanting the strongest acquisition cost to performance ratio, the M76S mid bin typically wins.
Chip binning is the process of sorting manufactured silicon by tested performance. MicroBT fabricates wafers containing thousands of chips and tests each chip individually after manufacturing. Chips above the highest performance threshold qualify for top bin products (M76S+). Chips above a mid threshold become mid bin (M76S). Remaining functional chips become base bin (M76). All three tiers use physically identical silicon from the same production run with no difference in manufacturing quality, durability, or design. Only the tested performance grade differs. Price typically scales with binning tier, and mid bin usually offers the best value ratio because it captures the largest volume of the natural production distribution.
380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 13 amps per phase at 5,200W continuous draw. At 480V three phase: approximately 11 amps per phase. Fits within standard 20 amp commercial breakers with headroom. Same three phase requirements as the entire M70 immersion family, so facilities designed for M76S+, M78, M78S, or M79 series units support the M76S without electrical modifications.
Dielectric fluid immersion tanks sized for the miner count plus thermal margin. Each M76S unit adds approximately 17,740 BTU per hour of thermal load, matching the M76S+ thermal footprint. Shares tank compatibility with M76, M76S+, M78, and M78S across the immersion family. Compatible dielectric fluids include single phase mineral oils, synthetic esters, and engineered two phase fluids. Typical fluid volume runs 40 to 60 liters per unit depending on tank geometry.
At MillionMiner's $0.08 per kWh onsite calculator: $11.85 daily revenue, $9.98 electricity, $1.87 net profit per day. At $0.07 per kWh industrial rates: approximately $8.74 daily electricity against similar revenue. At $0.04 per kWh negotiated industrial rates: $4.99 daily electricity, netting $6 to $7 daily profit per unit. Upper bin M76S output at 406 TH/s improves daily revenue by 12 percent over the 362 TH/s floor rate. A 19 unit M76S fleet on 100 kW panel produces approximately $115 to $130 daily net profit at $0.04 per kWh.
Jakákoli kryptoměna založená na SHA-256 proof of work. Bitcoin (BTC) je hlavním cílem. Další kompatibilní mince zahrnují Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB) a DigiByte (DGB SHA-256 řetězec). Sloučené těžení BTC spolu s BCH a BSV prostřednictvím podporujících poolů, jako jsou ViaBTC a F2Pool, přidává marginální sekundární příjmy bez snížení příspěvku na hash rate Bitcoinu.
Yes. All three M76 variants share identical chassis, power requirements, tank compatibility, and Whatsminer firmware. Mix bins freely across tanks based on acquisition cost optimization and fleet deployment strategy. Common deployment pattern: majority M76S units for value, some M76S+ units in slots where efficiency matters most, some M76 base units where budget is tightest. Fleet management handles mixed bin deployments transparently through unified Whatsminer firmware dashboards.
A 100 kW electrical panel supports 19 M76S units producing 6,878 TH/s aggregate hashrate. Alternative panel sizes scale linearly: 50 kW supports 9 units at 3,258 TH/s, 200 kW supports 38 units at 13,756 TH/s. The 5.2 kW tier maintains its density advantage over higher power tiers regardless of bin selection. Compared to 14 M78S units at 6,608 TH/s from the same 100 kW or 7 M79S hydro units at 6,510 TH/s, the M76S delivers more aggregate hashrate from identical electrical capacity.
Industrial deployment with three phase power and immersion infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission immersion cooling infrastructure. Step three: submerge M76S units in immersion tank slots. Step four: connect PSU power and Ethernet management. Step five: power on, allow fluid circulation to stabilize, find each miner IP through DHCP, configure pool URL and Bitcoin wallet through the Whatsminer web interface, verify hashrate reaches 351+ TH/s within 15 to 20 minutes per unit.
Immersion maintenance overhead. Monthly fluid quality testing (viscosity, dielectric strength, particulate content). Quarterly fluid filter inspection and replacement. Every 18 to 36 months full fluid replacement depending on fluid type. Heat exchanger cleaning every 6 to 12 months. Hashboard failure rates on immersion hardware run lower than air cooled because chips operate at consistent temperatures. Higher unit count compared to M78 or M79 deployments increases per fleet maintenance cycles. Budget 3 to 5 percent of acquisition cost annually per unit.
Any Stratum compatible Bitcoin pool. Foundry USA leads by network share. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts reducing daily variance. For fleet deployments above 3.6 PH/s (equivalent to 10+ M76S units), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates.
No. The M76S requires 380 to 480V three phase industrial power unavailable in residential settings, dielectric fluid immersion tanks with fluid management infrastructure, and professional installation for both electrical service and fluid systems. Home mining hardware caps at around 3,500W per unit on standard 240V 20A circuits. For high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling. The M76S is strictly industrial hardware.
Depends on the price differential and your electricity rate. If the M76S+ commands less than 15 percent price premium over the M76S at your supplier, the upgrade to top bin typically pays back through daily efficiency savings within 2 to 3 years at any electricity rate above $0.05 per kWh. At larger price premiums above 20 percent, the M76S value proposition strengthens. Run the acquisition cost versus daily electricity savings math with your specific supplier pricing before deciding.
MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from fluid quality neglect, contamination from improper immersion handling, physical damage during tank maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document fluid quality testing schedule and maintenance logs to protect warranty coverage.
Yes. MillionMiner operates managed hosting facilities with immersion cooling infrastructure capable of supporting M76S deployments. Hosted deployment eliminates the facility infrastructure CapEx. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.
Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M76S units automatically through network scanning. Additional immersion specific monitoring metrics appear in supported dashboards. Mixed brand and cooling type fleets handle through unified dashboards.
Bitmain does not currently ship a direct equivalent at the M76S's 5.2 kW tier. Closest Bitmain alternatives include Antminer S21+ Immersion variants running different hashrate and power envelopes. For operators standardizing on immersion cooling at the lightest power tier, the M76 series (M76, M76S, M76S+) gives MicroBT a unique product position with no direct Bitmain competitor. MicroBT currently holds the stronger immersion portfolio for facilities committed to dielectric fluid infrastructure at sub 7 kW per unit power budgets.
Acquisition cost per unit plus infrastructure and operations. CapEx at fleet scale: three phase electrical service, immersion tanks ($8,000 to $25,000 per rack), fluid fills ($1,500 to $4,500 per tank), heat exchanger and pump systems. Annual OpEx per unit at 5.2 kW: electricity at $3,650 at $0.08 per kWh or $1,825 at $0.04 per kWh, fluid maintenance ($150 to $500 per unit annually), spare parts. Higher unit count per fleet compared to higher power tier deployments increases total maintenance labor, which partly offsets the CapEx savings from lower thermal rejection requirements.
Within the 5.2 kW immersion tier: the Whatsminer M76S+ at 390 to 440 TH/s is the top bin upgrade path, and M76 at 336 to 374 TH/s is the base bin alternative for volume fleet buyers. Cross tier at MicroBT: the M78 at 440 TH/s and M78S at 472 TH/s cover the 7 kW immersion tier for operators with more electrical capacity per unit slot. Hydro variants M73S, M76 hydro, M79, M79S provide alternative liquid cooling approach. Cross brand options: the Antminer S21+ Immersion variants provide vendor diversification. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining on separate infrastructure. MillionMiner's ASIC hosting service accepts M76S units at negotiated industrial electricity rates.