Buy Hydro-Cooled ASIC Miners — Liquid-Cooled Hardware for Data Centers

Hydro-cooled miners use closed-loop water cooling instead of fans to remove heat from ASIC chips. The result is lower noise (around 50 dB compared to 75+ dB on air-cooled equivalents), better energy efficiency, higher rack density, and longer hardware lifespan. Hydro-cooled facilities achieve PUE of approximately 1.03, meaning only 3% energy overhead beyond the miners themselves, compared to 20%+ on air-cooled data centers. Hydro miners are designed exclusively for data center and industrial hosting operations. They require 380 to 415V three-phase power, liquid cooling infrastructure, and 8 to 10 L/min coolant flow rates. They are not suitable for home mining and should not be ordered for residential deployment. The MillionMiner catalog covers 68 hydro models including the full Bitmain S23 Hydro lineup (580 TH/s at 9.5 J/TH, 865 TH/s, and 1,160 TH/s on the S23 Hydro 3U), the S21 XP Hyd (473 TH/s at 12 J/TH), and WhatsMiner Hydro variants. The majority mine Bitcoin (SHA-256), with select Scrypt and KHeavyHash hydro options for Dogecoin/Litecoin and Kaspa operations. MillionMiner's US hosting facilities support full hydro infrastructure including plumbing, flow monitoring, and pressure management. For operators building their own setups, Lianli radiators and cooling cabinets are available in the Equipment category.

5.0
star star star star star
4.97
star star star star star
4.5
star star star star star
Buy Hydro-Cooled ASIC Miners — Liquid-Cooled Hardware for Data Centers
honeycomb-grid honeycomb-grid
סנן ומיין

ציוד מאושר

Bitmain & Lian Li authorised stock

Full System Support

כורים, קרר, תשתית ואביזרים

נקלט קריפטו

שלם עם BTC, ETH, USDT ועוד

תמיכה מקצועית

Cooling system specialists on hand

תשתית קירור מתקדמת

Hydro & Immersion Cooling: The Future of High-Density ASIC Mining

The era of air-cooled mining farms is giving way to liquid cooling infrastructure. As ASIC power densities exceed what air can efficiently dissipate — flagship Bitcoin miners now drawing 3,500W+ per unit — serious operations are moving to hydro-cooled and immersion-cooled systems that deliver dramatically lower PUE, higher hashrate density per square metre, near-silent operation, and extended hardware lifespan. We stock the full Bitmain Antminer Hydro series, Lian Li mining containers, immersion tanks, CDUs, radiators, pumps, coolant, cables, and every component needed to build a complete liquid cooling infrastructure from the ground up.

PUE Improvement

~1.03 PUE

vs 1.4–1.6 for typical air-cooled facilities

הפחתת רעש

~45 dB

vs 75–85 dB for air-cooled ASICs

Density Gain

3–5×

More hashrate per m² vs air-cooled racks

אורך חיים של חומרה

+30–50%

Extended ASIC lifetime vs air cooling


The Three Cooling Paradigms

אוויר מול הידרוליקה מול הטמעה: מה באמת משתנה

Every mining operation runs on one of three fundamental cooling approaches. The differences in cost, density, efficiency, and operational complexity are substantial — and choosing the wrong one for your scale is an expensive mistake.

Air Cooling

סטנדרט

הגישות המסורתיות: ASICs מושכים אוויר סביבה דרך הקייס עם מאווררים במהירויות גבוהות, ומוציאים את האוויר החם החוצה בחלק האחורי. כל ASIC שהכרת אי פעם מגיע עם מערכת זו בנויה מראש. אין צורך בתשתית חיצונית מעבר למקום מאוורר וחשמל.

Zero additional infrastructure cost

הגדרה פשוטה, בכל מיקום

Standard warranties and support

75–85 דציבלים — מאוד רועש

PUE 1.4–1.6 — high cooling overhead

שאיבת אבק פוגעת בחומרה עם הזמן

Low density — large floor area required

הטוב ל-

Home miners, small farms under 50 units, first-time operators

קירור הידרופוני

ASICsמקררים במים

מפעילי מיזוג הידרו הם רכיבי ASIC שתוכננו במיוחד כאשר בואי החום מקוררים במים במקום במאוורר. שבב ה-ASIC מייצר חום, המועבר למעגל סגור של מים דרך משטח קר פנימי. המים החמים זורמים למערכת קירור חיצונית (CDU) שמפזרת את החום — either לאוויר הסביבתי באמצעות מקרר יבש או למגדל קירור. המאווררים מבוטלים לחלוטין או מצומצמים באופן משמעותי.

40–50 dB — near-silent operation

PUE ~1.05–1.10 — very efficient

Standard rack-mountable form factor

No chemical coolant — uses standard water

דורש תשתית חיצונית של CDU / רדיאטור

צינורות, מחברים, משאבות מוסיפים עלות התקנה

חומרה ייעודית ל-ASIC להידרוהדרדרות דרושה

הטוב ל-

Mid-to-large farms, noise-sensitive locations, high-density deployments

Immersion Cooling

Full submersion

קירור בצלילה מטביע את כל החומרה של ASIC — לוחות, שבבים, וכל השאר — ישירות לתוך אמבטיית נוזל ד dielectric (שמן מעובד) בתוך מיכל אטום. הנוזל סופג חום ישירות מפני כל מרכיב בו זמנית ומתנקז למחליף חום. לא נעשה תנועת אוויר, לא פועלים מאווררים, לא נכנס לכלוך. הטרמודינמיקה שלה היא באופן בסיסי עליונה על פני כל שיטה מבוססת אוויר.

PUE ~1.02–1.03 — near-theoretical maximum

Works with standard air-cooled ASICs (fans removed)

צפיפות ה־hashrate הגבוהה ביותר למ"ר

Zero dust, corrosion, or humidity degradation

השקעה בהתחלתית הגבוהה ביותר בתשתיות

Dielectric fluid cost & ongoing management

Maintenance access requires fluid handling

הטוב ל-

Large industrial operations, space-constrained sites, maximum efficiency mandates


צלילה מעמיקה במיזוג מים

How Hydro-Cooled ASICs Work — and Why They Change the Economics

ASIC מקורר במים הוא מכשיר הייעודו — לא מנוע אוויר משודרג. סדרת Antminer Hydro של Bitmain (S19 Hydro, S21 Hydro) מגיעה ללא מאוורר צירי ומחליפה אותם בבלוק מים פנימי המחובר ישירות לרכיבי לוח ההאש. מד cooled — בדרך כלל מים נקיים או תערובת מים-גליקול המונעת קורוזיה — זורם דרך הבלוק הפנימי, סופג את חום שתובת ופריקומטים האש.

לולאת הקירור החיצונית כוללת משאבה (המזינה את הקרור במים דרך המעגל), מפלגות הפצה (המפרידות את הזרימה למספר מכונות), אביזרי גומיות גמישים עם חיבורים מהירים (החלפת מכונה ללא כלים) ויחידת הפצת הקירור (CDU) או מפזר חום שמפזר חום לסביבה. באקלים קר, קירור חופשי באמצעות מקררים יבשים יכול להביא את צריכת החשמל של מערכת הקירור הכללית לקרוב לאפס — ההישג של PUE הקרוב ל-1.0 בחודשי החורף.

The critical operational advantage of hydro over immersion is serviceability: a hydro miner sits in a standard rack, connects to quick-disconnect hose fittings, and can be swapped in under two minutes without fluid handling equipment. Maintenance is nearly identical to air-cooled hardware — you just unplug hoses instead of power cables. For operations that cycle hardware frequently or need rapid fault resolution, hydro cooling offers the best balance of efficiency and operational simplicity.

לולאת קירור ההידרו

איך המים זורמים דרך מערכת כריית הידרואי

01

Chilled Water Supply

CDU or dry cooler delivers cooled water (typically 30–40°C) to the distribution manifold at the head of the rack.

02

Manifold Distribution

A supply manifold splits flow across all machines in the rack. Each machine connects via quick-disconnect hose fittings — no tools required for connection or removal.

03

מגש קירור פנימי

Inside each hydro ASIC, water flows through a cold plate bonded directly to the hash board chips. Heat transfers from chip to water. Water exits 10–20°C warmer than it entered.

04

Return Manifold Collection

מים חמים מכל המכונות מצטברים במאגר החזרה ומוזרמים חזרה ל-CDU כזרם חם משולב.

05

Heat Rejection (CDU / Dry Cooler)

ה- CDU מעבירה חום מלולאת הכרייה הסגורה ללולאת פינוי חיצונית — או מקרר יבש (יחידת חוץ מבוססת מאוורר) או מגדל קירור להתקנות גדולות. באקלים קר, מקרר יבש יכול לפעול עם כוח מאוורר קרוב לאפס.


Immersion System Anatomy

What's Inside an Immersion Cooling System

Immersion Tank

מיכל אטום ממתכת אלומיניום מצופה באסבסט או מפיברגלס — בדרך כלל בנפח 1,000–3,000 ליטר — המכיל את החומרה. כל מיכל מחזיק 12–48 מעבדי ASIC סטנדרטיים (המאווררים הוסרו), המונחים אופקית בתוך מסגרות שנבנו במיוחד לכך. כל הפנים מלא בנוזל דיאלקטרי.

Dielectric Fluid

שמן מינרלי מעובד או נוזל dielectric סינתטי (למשל Engineered Fluids BitCool, 3M Novec). לא מוליך חשמל ולכן בטוח במגע עם אלקטרוניקה חיה. מוליכות תרמית כ-4 פעמים יותר טובה מאוויר. אינו דליק. ניתן לשימוש חוזר אינסוף עם סינון. יש למלא מחדש באופן תקופתי עקב התאדות.

Heat Exchanger Coil

גליל של צינור חום-העברה שוכן טובע באמבט dielectric חמה. מים נקיים מחולפים דרך הגליל הזה, סופגים חום מהנוזל ומעבירים אותו מחוץ לתוך המכל. הנוזל ומים לעולם לא מערבבים — הם מחליפים חום דרך קיר הגליל בלבד.

CDU / External Cooling Loop

המים החמימים מתוך סליל המכל זורמים ליחידת הפצת קירור חיצונית, מקרר יבש או מגדל קירור לשחרור סופי של חום לאטמוספירה. זה זהה במבנה ללולאה החיצונית של הקירור ההידרובי.

סינון ומוניטורינג

Continuous filtration removes particulate contamination from the dielectric fluid. Sensors monitor fluid temperature, level, and flow rate. Management software tracks per-tank thermal load and flags anomalies.

Immersion Cooling Deep Dive

Total Submersion: Why Immersion Cooling Is the Endgame for Large Operations

קירור הטבילה שונה באופן גורף מכל שיטת קירור אחרת מכיוון שהוא מְבַטֵל את הגבול התרמי בין אמצעי הקירור למקור החום. בקירור באוויר, החום חייב לנסוע מ-השבב ל-הפיזור חום, לכנפי המון חום, ולאוויר הזורם — ממשקים מרובים, שכל אחד מהם מוסיף להתנגדות תרמית. בטבילה, הנוזל הדיאלקטרי מגע בכל משטח של כל רכיב באופן ישיר. התוצאה היא טמפרטורת צומת השבב נמוכה ב-30–50°C בהשוואה למערכות מקוררות באוויר שמריצות עומסים זהים.

טמפרטורות נמוכות יותר של השבבים מביאות לתועלות תפעוליות מצטברות. שיעורי הכשל של ASIC מקושרים ישירות למחזור חום וטמפרטורות גבוהות מתמשכות — חומרה מושקעת בטבילה במים זוכה באופן שגרתי_bpאורך חיים תפעולי של 5–7 שנים לעומת 2–3 שנים למכונות מקוררות באוויר בסביבות תעשייתיות עבודה קשות. רבים מהמנהלים מפעילים ASICs בשיטת הטבילה בתדרי שעון שמרניים כדי למקסם את האורך חיים, או מעל-clock באגרסיביות כאשר ידוע שיש מרחב חום פנימי. שתי האסטרטגיות הללו הולמות בדרכים שהן פשוט לא קיימות עם קירור באוויר.

היתרון המרכזי האחר הוא גמישות חומרה: רוב מיכלי הטבילה לזרם יחיד מקבלים אסיקי קירור אוויר סטנדרטיים עם המאווררים מוסרים (חיבורי מאווררים מחוברים עם נגיף); משמעות הדבר היא שלא צריך לרכוש חומרת טבילה ייעודית — הקשיחים הקיימים שלך, כמו Antminer S21s, WhatsMiner M60s או KS5s, יכולים להתחבר ישירות למיכל עם שינוי זול במאוורר. זהו יתרון משמעותי ביעילות ההון בהשוואה לקירור הידרו, שמצריך מכשירים ייעודיים עם גרסה הידרו-מיוחדת.


Head-to-Head

Hydro vs Immersion: Which Is Right for Your Operation?

Both are dramatically superior to air cooling. The choice between them comes down to scale, operational style, and capital allocation.

שיקול דעת קירור הידרופוני Immersion Cooling
PUE ~1.05–1.10 ~1.02–1.03
Upfront Infrastructure Cost Medium — CDU, hoses, manifolds גבוה — מכלים, נוזלים, CDU, סינון
Hardware Requirement גרסאות ASIC הידרואלקטריות ייעודיות -ASICS סטנדרטיים (מאווררים שהוסרו)
Maintenance Access Standard rack — fast & clean Tank access — fluid handling required
Hardware Swap Time < 2 minutes 15–30 minutes (drain or crane)
Chip Temperatures Excellent — 20–30°C lower than air Best possible — 30–50°C lower than air
מרחב עבודה לאוברקלוקינג טוב Excellent — most thermal headroom
אורך חיים של חומרה +30–40% לעומת אוויר +50–70% לעומת אוויר
היכולת להרחיב Scales well per rack Scales best per m² floor area
רמת רעש ~40–50 dB ~35–45 dB
Fluid Management מים/גליקול — פשוט שמן דיאלקטרי — ידע מקצועי
סולם אידיאלי 20–500+ יחידות 100–10,000+ units

Rule of thumb: if you need to swap hardware frequently and want minimal operational complexity, hydro wins. If you are building a fixed large-scale installation and want the absolute lowest PUE and longest hardware life, immersion wins. Many professional operations run hydro for their newest-generation hardware (where frequent rotation is likely) and immersion for older-generation machines running extended depreciation cycles.


מה שיש לנו במלאי

ביטמיין וליאן לי: תשתית הידרו וטבילה מלאה

Everything you need to build a complete hydro or immersion cooling system — from the miners themselves to every pipe, pump, and panel.

Bitmain

Antminer Hydro Miners

ASICs מקוררים במים שנבנו למטרה זו. מאווררים הוחלפו בלוח קר פנימי. חיבורים אחוריים עם חיבור מהיר להתקנה ללא כלים. הקו הנוכחי כולל את S19 Hydro (158 TH/s), S21 Hydro (335 TH/s) ו-KS5 Hydro עבור קספה. מיועדים להשתלב ישירות עם מערכות CDU של ביטמיין או תשתיות קירור של צד שלישי.

S19 Hydro S21 Hydro KS5 Hydro
Bitmain & Lian Li

קונטיינרים חפירה

מכולות שינוע תקניות ISO מוכנות מראש להידר או כרייה בצלילה. מכולות הכרייה של ליאן לי משתרעות קירור, הפצת חשמל, מתגי רשת ואבטחה פיזית ביחידה אחת שניתן לפרוס. הפתרונות של ביטמאיין למכולות מתוכננים סביב סדרת ה-ASIC ההידר שלהם. זמינות בגרסאות של 20 רגל ו-40 רגל — קיבולת של 100–400 יחידות לכל מכולה.

20 רגל ו-40 רגל הכנסה והפעלה indoors ו- בחוץ
מרובות מותגים

Immersion Tanks

מכלי טבילה דיאלקטריים חד-פאזיים במגוון קיבולות (קונפיגורציות של 12 יחידות, 24 יחידות, 48 יחידות). בנייה מפלדת אל-חלד, סליל מחליף חום משולב, חיבורי כניסה/יציאת נוזלים, וכיסויי גישה עליונה. Designed לפעילות רציפה של 24/7. תואם עם ASICs מקוררים באוויר סטנדרטיים (מתאם מאוורר) וכן חומרה ייעודית לטבילה.

12 / 24 / 48 unit נירוסטה
Bitmain & Third-Party

יחידות ניהול קרינה ומעיינות הידרואליים

יחידות הפצת תצלורת קירור (CDUs) ומקררי ייבוש קר for לולאת הוצאת החום החיצונית. טווח ה-CDU של ביטמאין מותאם לשילוב ישיר עם סדרת Antminer Hydro, הזמינה בטווח קיבולות מ-50kW עד 400kW ליחידה. מקררי ייבוש מצד שלישי ומחליפי חום לוח זמינים לעיצוב מערכות מותאם וללולאות קירור הטמעות חיצוניות.

50kW – 400kW indoors ו- בחוץ
System Components

Pumps & Distribution Manifolds

Circulation pumps for both hydro and immersion primary loops. Sizing from small single-rack pumps (20–50 L/min) to large facility-scale units. Stainless or brass distribution manifolds in 6-way, 12-way, and 24-way configurations for splitting coolant flow across multiple machines or racks. Balancing valves and flow meters available for precise per-machine flow optimisation.

שיעורי זרימה שונים stainless & brass
כל דבר אחר

צינורות, מחברים ואביזרים

Quick-disconnect push-fit couplings compatible with Bitmain Hydro series rear fittings (G1/4", 3/8", 1/2" options). Reinforced EPDM coolant hoses in various lengths. Dielectric fluid (single-phase engineered mineral oil and synthetic options). Corrosion inhibitor concentrate for water-glycol systems. Filtration cartridges, fluid analysis kits, temperature sensors, flow meters, and monitoring hardware.

QD couplings נוזל דיאלקטרי Monitoring

Watch Out

טעותים נפוצות במיזוג אוויר נוזלי

מערכות קירור נוזלי מתוגמלות בתכנון נכון ומענישות על אימפרוביזציה. אלו הם הטעויות שעלותן הכי גבוהה למפעילים.

הקטנת גודל לולאת הקירור להתרחבות עתידית

הטעות היקרה ביותר בתכנון מערכות הידרו. מפעילים מגדירים לעיתים קרובות את קיבולת המשאבות, המניפות וקיבולת יחידת הקומפרסור (CDU) בדיוק למספר המכשירים הקיימים — ואז מוסיפים יחידות ומגלים שהמערכת מוצפת תרמיתית. תכנן את הלולאה הראשית שלך ל-150% מהקיבולת המתוכננת שלך מהיום הראשון. שדרוגי משאבות וקיבול נוסף ל-CDU אפשריים אך הינם משבשים. יציאות המניפות וקטרות הצינורות כמעט בלתי אפשרי להרחיב מבלי לבנות את הלולאה מחדש.

שימוש במי ברז ללא טיפול במערכות הידרותרפיה

Untreated tap water contains dissolved minerals, chlorine, and biological material that will cause scale buildup on cold plates, corrosion at fittings, and microbial growth in the loop. Always use deionised water with a corrosion inhibitor blend specifically formulated for mixed-metal cooling systems (aluminium cold plates, copper fittings, stainless manifolds). Test the loop chemistry quarterly. A blocked cold plate from scale buildup kills an ASIC as surely as a failed fan.

הסרת מאווררים מ-ASICs לפני אישור תאימות להטמעה

Not every ASIC can be safely immersed. Some machines have thermal paste formulations or capacitor types that degrade in dielectric fluid. Some firmware exhibits fan-fault shutdowns that cannot be disabled. Verify immersion compatibility with your specific hardware model and firmware version before buying a tank. Bitmain publishes immersion compatibility lists — consult them. A standard S21 Pro is confirmed immersion-compatible; other models require verification.

התעלמות ממהירות זרימת הקירור לכל מכונה במערכות הידרו

לכל מכונת Antminer Hydro יש קצב זרימת קירור מינימלי מוגדר (בדרך כלל 4–8 ליטר בדקה לכל יחידה). זרימת יתר של מכונה גורמת ללוח הקרח להתמלא בחום באופן מקומי גם אם טמפרטורת המים הכללית נראית תקינה. זהו גורם שכיח לכשלי לוחות ההאש המסתוריים בהתקנות הידרואיות שראו טמפרטורה תרמית תקינה במצלמות הטמפרטורה הכוללת. התקן מדדי זרימה במפגש והאיזן את זרימת המכשיר במהלך הכינון.

בהנחה שתעלות הטבילה הן ללא צורך בתחזוקה

מיכלי טבילה דורשים תחזוקה נמוכה אך לא אפסית. נוזל דיאלקטרי סופג אדי מים וזיהום חלקיקי עם הזמן — צמיגות הנוזל וקבוע הדיאלקטרי מתדרדרים. רוב היצרנים ממליצים על בדיקות נוזל כל 6–12 חודשים והחלפת נוזל מלאה כל 2–3 שנים בהתאם לתנאי הפעלה. הזנחה של זה מובילה לביצועים תרמיים מופחתים, קורוזיה פוטנציאלית, ובמקרים קיצוניים הנוזל הופך להיות מעט מוליך. תקצב לניהול נוזלים מתמשך מהיום הראשון.

קנייה של תשתית הידרובלית ללא אימות מקורות מים באתר

מערכות קירור הידרו דורשות מקור אמין למים תוספת כדי לפצות על אובדות התאדות במקרר היבש. מתקנות גדולות יכולות לאבד מאות ליטרים ביום כתוצאה מהתאדות במזג אוויר חם. אמת שהאתר שלך יש מקור מים מספק, איכות מים מתאימה, ואישור לשחרור מים אחוריים (אם משתמשים במגדלי קירור המתאדים). זהו נושא תכנון אתר שהרג את פרויקטי ההידרו לאחר שהבנייה תוּסתה.


שאלות נפוצות

Hydro & Immersion Cooling FAQ

תשובות לשאלות שאנו נשאלים הכי הרבה לפני שמפעילים עושים את המעבר לקירור נוזלי.

במרבית המקרים כן — ה-Antminer S21 ו-S21 Pro תואמים באופן מאושר לקירור טבילה בדידקטי חד-פאזי. התהליך כולל הוצאת המאווררים האקסיאליים, גישור של חיבורי המאווררים עם נגד (כדי למנוע כיבויי תקלה במאוורר), ואפשרות ליישם משחת תרמית תואמת טבילה על הרכיבים שבשבבים. ביטמיין מפרסמת רשימת תאימות רשמית לפריסת טבילה — תמיד לבדוק זאת לגרסת הקושחה הספציפית שלך לפני שינוי חומרה. ה-S21 Hydro הוא מוצר שונה: וריאנט מים קירור שמיועד במיוחד ואינו משתמש בנוזל דידקטי ולא ניתן לשימוש במכל טבילה.

אלו שני גישות fundamentally שונות. אנט miner Hydro (למשל S21 Hydro) הוא מכשיר ייעודי עם בלוק מים פנימי — מקרר זורם דרך המכשיר עצמו באמצעות חיבורים מהירים מלפנים. הוא דורש לולאת קירור הידרואית ייעודית ולא ניתן להשתמש בו בבריכת תימשום או בפעולה באוויר. אנט miner סטנדרטי (למשל S21 Pro) הוא מכשיר מקורר באוויר שניתן לשנותו לפעולה בבריכת תימשום על ידי הסרת מאווררים. בריכת התימשום היא התשתית; ה-ASIC הסטנדרטי הוא החומרה. Hydro = ASIC מקורר בנוזל בארון ריק. תימשום = ASIC סטנדרטי הטבוע במיכל של נוזל דיפולטי.

Single-phase immersion tanks use engineered dielectric mineral oil or synthetic dielectric fluid. Common products include Engineered Fluids BitCool BC-888, Cargill Nytro Bio 300X, or equivalent synthetic dielectrics. The fluid is non-flammable, non-toxic, and electrically non-conductive. It does not need to be changed frequently under normal operation — most operators test fluid annually and replace every 2–4 years depending on load and operating environment. Fluid is a significant upfront and ongoing cost: budget approximately €1,500–€3,000 per tank fill depending on capacity and fluid specification.

תקציב תשתית מוערך ל-50 יחידות אנטמיינר הידרו: CDU (קיבולת 100–150 ק"ו) €8,000–€15,000; שני מתקנים עם מפזרים וחיבורים €3,000–€5,000; משאבה וחומרה למחזור €1,500–€3,000; צינורות, חיבורים מהירים ואביזרים €1,500–€2,500; מקרר יבש (יחידת פינוי חום חיצונית) €5,000–€12,000; עלות התקנה משתנה בהתאם לאתר. סך העלות התשתית ללא המינרים עצמם: כ-€20,000–€37,000 לפריסת הידרו של 50 יחידות. עלות תשתית לכל יחידה של €400–€740 בדרך כלל מתאוששת בתוך 12–18 חודשים באמצעות החסכון בצריכת החשמל לעומת פעולה באוויר קירור.

כן — טווח מכולות הכרייה של Lian Li נועד להיות בלתי תלוי בחומרה ומסוגל לתמוך באינטגרציה של סדרת Bitmain Hydro. מכולות Lian Li כוללות תשתית להפצת קירור מוכן להפעלה, ונקודות חיבור הצנרת תואמות לחיבורים מהירים סטנדרטיים המשמשים במכונות Bitmain Hydro. לקבלת תאימות ספציפית בין קונפיגורציה מסוימת של מכולת Lian Li לבין גרסת Antminer Hydro ספציפית, פנו לצוות המכירות שלנו — אנו יכולים לאשר את דרישות האינטגרציה המדויקות וכל מפיצי ההסתעפות הדרושים.

Yes, and cold climates are actually ideal for hydro and immersion cooling economics. When ambient temperatures fall below 15–20°C, dry coolers can achieve "free cooling" — rejecting heat with minimal fan power and zero refrigerant energy. In climates with sustained cold winters, hydro PUE can approach 1.01–1.02 for extended periods. For outdoor or cold-climate deployments, use a water-glycol mix (typically 30–40% propylene glycol) in the primary loop to prevent freezing. All our CDUs and dry coolers are available with glycol-compatible specifications for outdoor installation.

מכונות Bitmain Antminer Hydro נושאות את האחריות הסטנדרטית של Bitmain למשך 180 יום המכסה תקלות ייצור בתנאי שימוש רגילים — זהה ליחידות Antminer המאווררות באוויר. האחריות דורשת פעולת המכשיר בתוך טווחי הטמפרטורה והזרימה של נוזל הקירור שצוינו על ידי Bitmain; עבודה מחוץ לתנאים אלה (זרימה נמוכה, טמפרטורת נוזל קירור גבוהה מדי) מבטלת את הכיסוי. אחריות על CDU ותשתיות קירור משתנה לפי יצרן — בדרך כלל 12 חודשים על רכיבים מכניים וחשמליים. תנאי האחריות המלאים מפורטים בדף המוצר בכל עמוד. לפריסות גדולות, זמינות אפשרויות אחריות מורחבת — צרו קשר עם צוות המכירות שלנו.

Yes. This is something we actively support. Contact our team with your planned machine count, site power capacity, available floor area, and climate zone — and we will put together a full system design including CDU sizing, manifold configuration, pump specification, dry cooler or cooling tower recommendation, and a complete bill of materials. We supply everything from the miners to the last hose fitting, and we can recommend installation partners in most European markets. There is no charge for system design consultations for customers purchasing equipment through us.

מִוכָנָן לבנות את מערכת הקירור הנוזלי שלך?

Browse our full range of hydro miners, immersion tanks, containers, CDUs, and accessories above. If you are planning a new hydro or immersion deployment and want help sizing the system correctly, contact our team — we offer free system design consultations for customers building complete installations.