In Stock

Bitmain

Bitmain Antminer S23E Hyd 2U (865TH)

मॉडल: S23E Hyd 2U

स्थिति: new

865 TH/s hydro cooled SHA-256 Bitcoin miner at 8,650W and 10 J/TH efficiency in a 2U rack mount form factor. The density optimized middle tier of Bitmain's S23 hydro lineup, fitting up to 21 units per standard 42U rack for 18.2 PH/s per cabinet at roughly 182 kW. 49 percent more hashrate than the base S23 Hydro at a lower unit cost than the S23 Hyd 3U. 50 dB near silent hydro cooled operation. 600 x 483 x 86 mm at 17 kg. PSU included. Ships from MillionMiner with Bitmain warranty and free DDP delivery worldwide.

865 TH/s 8650W SHA-256 10 J/TH

Select Availability

Quantity

कुल मूल्य

$11,699.00

Genuine

Tested hardware

Worldwide

Global shipping

Support

खनन विशेषज्ञ

Hashrate

865 TH/s

Power

8650 W

प्रभावशीलता

10.00 J/TH

शोर

50 dB

Estimated Mining Returns

वर्तमान बीटीसी मूल्य और नेटवर्क कठिनाई के आधार पर। केवल संकेतक।

Period दैनिक साप्ताहिक मासिक
Income
$30.78 $215.46 $923.40
बिजली
-$16.61 -$116.27 -$498.30
Profit
$14.17 $99.19 $425.10

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Full Specifications

Hashrate 865 TH/s
Power Consumption 8650 W
प्रभावशीलता 10.00 J/TH
एल्गोरिदम SHA-256
Model S23E Hyd 2U
Release Year अप्रैल 2026
शोर का स्तर 50 dB
आयाम 600 x 483 x 86mm
Weight 17 kg
ऑपरेटिंग तापमान 5 - 45 °C
Humidity 5 - 95 %
Cooling Type Hydro
रेैक प्रारूप 2U

What's in the Box

S23E Hyd 2U
Power supply unit (PSU)
पावर केबल
तेज़ शुरुआत गाइड

सामग्री बैच के अनुसार भिन्न हो सकती है। क्रम पुष्टि में दी गई निश्चित वस्तुएं।

त्वरित सेटअप

1

Connect PSU to miner and plug into the outlet

2

अपने राउटर या स्विच से ईथरनेट केबल कनेक्ट करें

3

राउटर एडमिन या आईपी स्कैनर टूल के माध्यम से खननकर्ता का आईपी पता खोजें

4

वेब इंटरफ़ेस खोलें, पूल URL और वॉलेट दर्ज करें — माइनिंग शुरू करें

उत्पाद विवरण

Bitmain Antminer S23e Hyd 2U 865 TH/s Hydro Bitcoin Miner: Specifications, Rack Density Economics, and Professional Deployment Guide

The Antminer S23e Hyd 2U is Bitmain's mid tier entry in the current S23 hydro cooled lineup, targeting professional mining operations that want maximum rack density without committing to the full 3U platform. At 865 TH/s of SHA-256 hashrate and 8,650W continuous wall draw, the S23e Hyd 2U delivers 10 J/TH efficiency through liquid cooling plumbing that integrates directly with existing facility infrastructure.
The S23 hydro family now includes three options for operators. The base S23 Hydro runs at 580 TH/s and 9.5 J/TH in a standard chassis. The S23e Hyd 2U steps up to 865 TH/s at 10 J/TH in a 2U rack mount form factor. The S23 Hyd 3U reaches 1,160 TH/s at 9.5 J/TH and 11,020W in the larger 3U chassis. The S23e Hyd 2U produces 49 percent more hashrate than the base S23 Hydro while drawing only 57 percent more power, and it matches the 3U variant's efficiency class at a meaningfully lower acquisition cost per unit.

Rack density is where the S23e Hyd 2U differentiates. The 509 x 481 x 87 mm 2U chassis fits up to 21 units in a standard 42U rack compared to 14 units for 3U hardware. For data center operations where rack space carries real infrastructure cost, that translates to roughly 18.2 PH/s per 42U rack at approximately 182 kW of sustained draw. Five unit pilot deployments produce 4.33 PH/s of combined SHA-256 hashrate for operators testing the platform before scaling.

Liquid cooling supports antifreeze, pure water, and deionized water as coolant media. Operators with existing S19 Hydro or S21 Hydro infrastructure can integrate S23e Hyd 2U units into the same plumbing loops with appropriate temperature and flow management. The near silent 50 dB operating noise is a direct consequence of the hydro cooling: no high RPM fans means the unit runs at library volume levels despite processing 8,650W of thermal output.

Power delivery is the deployment constraint. The S23e Hyd 2U requires higher voltage setups than typical air cooled ASICs and is unsuitable for most home electrical infrastructure. Professional three phase power with appropriate breaker capacity and circuit protection is assumed. The PSU is included with the unit, unlike many older Antminer products that shipped without power supplies. Ethernet connectivity and the standard Antminer web management interface handle pool configuration, hashrate monitoring, temperature tracking, and fleet integration with Bitmain's management tools or third party platforms.

First production batches ship Q2 2026 per Bitmain's announced schedule. Pricing varies by distributor and batch timing, running approximately $19,529 for June 2026 delivery through approximately $24,999 for earlier availability. Each unit carries Bitmain's standard 360 day factory warranty covering manufacturing defects under normal operation. SHA-256 algorithm compatibility means the hardware mines Bitcoin (BTC), Bitcoin Cash (BCH), Bitcoin SV (BSV), and other SHA-256 coins through any standard mining pool.

Bitmain Antminer S23e Hyd 2U: Rack Dense Hydro Bitcoin Mining at 865 TH/s

The Antminer S23e Hyd 2U sits between Bitmain's standard S23 Hydro (580 TH/s single unit) and the S23 Hyd 3U (1,160 TH/s at 11,020W) in the current hydro cooled lineup. At 865 TH/s and 8,650W wall draw it delivers 10 J/TH efficiency, matching the efficiency tier of the 3U variant at a lower unit price point. The real advantage is rack density: 2U form factor fits up to 21 units in a standard 42U rack versus 14 for 3U hardware, translating directly to higher hashrate per rack unit and lower infrastructure cost per terahash for operators with existing liquid cooling plumbing.

Not a home miner. This is enterprise deployment hardware requiring professional cooling infrastructure and high voltage power delivery. First production batch ships Q2 2026 with 360 day Bitmain factory warranty.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Bitmain Antminer S23e Hyd 2U 865 TH/s Bitcoin Miner

Bitmain's 2U rack mount hydro cooled Bitcoin miner delivering 865 TH/s of SHA-256 hashrate through 8,650W total draw at 10 J/TH efficiency. Purpose built for professional mining facilities with existing liquid cooling infrastructure. 50 dB near silent operation, 19.1 kg compact form factor fitting 21 units per standard 42U rack. Q2 2026 release. Includes PSU and 360 day factory warranty.

865 TH/s SHA-256 at 10 J/TH Through Liquid Cooling

The S23e Hyd 2U delivers 865 TH/s of Bitcoin hashrate at 8,650W wall draw for 10 J/TH efficiency. Hydro cooling handles the 29,500 BTU/hr thermal load silently at 50 dB, compared to the 75 dB.

Units Per 42U Rack: The Density Advantage

The 2U form factor (509 x 481 x 87 mm) fits up to 21 units in a standard 42U server rack compared to 14 for 3U hardware. That is 18.2 PH/s per rack at roughly 182 kW sustained draw.

The Mid Tier Sweet Spot in the S23 Hydro Lineup

S23 Hydro: 580 TH/s at 9.5 J/TH (base). S23e Hyd 2U: 865 TH/s at 10 J/TH (this product). S23 Hyd 3U: 1,160 TH/s at 9.5 J/TH. The 2U variant produces 49 percent more hashrate than the base Hydro.

FAQ

अक्सर पूछे जाने वाले प्रश्न

Three hydro options cover the current S23 family. The base S23 Hydro runs at 580 TH/s, 5,510W, and 9.5 J/TH in a standard chassis. The S23e Hyd 2U (this product) runs at 865 TH/s, 8,650W, and 10 J/TH in a 2U rack mount form factor. The S23 Hyd 3U runs at 1,160 TH/s, 11,020W, and 9.5 J/TH in the larger 3U chassis. The S23e Hyd 2U occupies the middle tier, producing 49 percent more hashrate than the base Hydro at 57 percent more power while matching the 3U efficiency class at a meaningfully lower unit acquisition cost. For operations scaling incrementally into liquid cooled mining without committing to full 3U infrastructure, the 2U variant is the correct choice.

Three phase commercial or industrial power is assumed. The S23e Hyd 2U requires higher voltage than standard residential or small facility electrical infrastructure can deliver, which Bitmain and authorized distributors flag explicitly before sale. At 380 to 480 volts three phase, the unit draws approximately 13 to 23 amps depending on voltage configuration. Breaker capacity, circuit protection, and PDU sizing must match the sustained 8,650W draw. The PSU is included with the miner, unlike older Antminer products that shipped without power supplies. Confirm your facility voltage and electrical infrastructure with Bitmain or your distributor before purchasing.

The unit requires existing hydro cooling infrastructure with appropriate flow rate and temperature management. Compatible coolant media include antifreeze mixtures, pure water, and deionized water. Operators running existing S19 Hydro, S21 Hydro, or S21 XP Hydro fleets can integrate S23e Hyd 2U units into the same plumbing loops with appropriate heat exchanger and pump sizing for the additional thermal load. A single unit generates approximately 29,500 BTU per hour of heat that the liquid loop must dissipate. New operators entering hydro mining need to budget for the full cooling infrastructure separately from hardware acquisition cost.

50 dB is library quiet, roughly 50 percent less perceived volume than the 75 dB standard of air cooled ASICs. The S23e Hyd 2U produces near silent operation because hydro cooling eliminates the high RPM fans that generate most industrial mining noise. That opens deployment options that air cooled hardware cannot match: office buildings, commercial spaces with noise restrictions, hotels, and other environments where 75 dB would be unacceptable. The constraint is not noise for this product. It is the power and cooling infrastructure requirements that determine where deployment is feasible, not acoustic output.

Third party tracking as of early 2026 shows the S23e Hyd 2U generating approximately $33 in daily Bitcoin revenue at 865 TH/s against current difficulty. At $0.07 per kWh residential power, electricity costs approximately $14.53 daily, netting around $18 to $19 per day in profit. At $0.04 per kWh industrial rates, daily electricity drops to approximately $8.30 and daily profit rises accordingly to the $24 to $25 range. ROI projections vary from 30 to 56 months depending on Bitcoin price trajectory and your electricity rate. These numbers move constantly with Bitcoin price, difficulty, and power cost. Always run current figures through a mining calculator before committing capital at this scale.

Yes, any SHA-256 coin. The hardware is algorithm specific, not coin specific. Bitcoin (BTC) is the primary target because it has the largest market cap and deepest mining pool infrastructure. Bitcoin Cash (BCH), Bitcoin SV (BSV), and Fractal Bitcoin also use SHA-256 and accept hashrate from the S23e Hyd 2U. Merged mining on some SHA-256 forks is supported through pools that handle the mechanics. For pure Bitcoin mining, point at Foundry USA, F2Pool, AntPool, ViaBTC, or any other major SHA-256 pool through standard Stratum protocol.

Any SHA-256 Stratum pool. For 865 TH/s fleet deployments, pool selection matters more than for individual units because latency and rejected share rates compound across hashrate volume. Foundry USA dominates North American hashrate and offers low latency for US based operations. F2Pool leads global hashrate and provides broad geographic server coverage. AntPool and ViaBTC offer competitive fee structures. Enterprise scale operators typically split hashrate across two or three pools for risk diversification rather than concentrating on a single provider. Pool fees range from 0.5 to 2.5 percent across major options.

Bitmain's standard 360 day factory warranty covers manufacturing defects under normal operation. Some European distributors like Antminer Distribution EU offer up to two years extended warranty coverage for operations running through their channel. First year reliability on any new Bitmain hydro product requires active monitoring: thermal anomalies, flow rate drops, and hashrate degradation all signal issues that warranty covers before they cause permanent damage. The 2U form factor means component access for repair or replacement is more constrained than standard chassis hardware. Factor warranty terms into your purchase decision, especially for large fleet orders where unit failures compound.

Depends on scale and budget. The 3U variant offers 34 percent more hashrate per unit (1,160 TH/s versus 865 TH/s) at slightly better efficiency (9.5 versus 10 J/TH) but higher acquisition cost per unit. The 2U variant offers better rack density (21 versus 14 units per 42U rack), lower unit acquisition cost, and more incremental scaling flexibility. For operations deploying under 5 PH/s, the 2U's lower unit cost and rack density advantage usually win. For operations deploying over 10 PH/s where rack space is less constrained than unit count, the 3U's higher per unit output may be preferable. Both ship Q2 2026 with similar warranty terms.

Beyond the 8,650W direct power draw, factor in cooling infrastructure costs. Liquid cooling loops require pumps, heat exchangers, and temperature management that add approximately 10 to 15 percent to total facility power consumption. Treated water or coolant replacement runs roughly $200 to $500 annually per unit in industrial applications. Pump maintenance, leak monitoring, and flow sensor calibration add smaller recurring costs. Total operating expense typically runs 15 to 25 percent higher than raw electricity cost when all cooling infrastructure is included. For a single unit at $0.07 per kWh: approximately $15 daily direct electricity plus $2 to $4 daily amortized cooling infrastructure, totaling $17 to $19 per day operational cost.

Yes on the network side. Every SHA-256 miner connects independently through standard Stratum protocol to any Bitcoin pool, so mixing generations in the same fleet creates no compatibility issues. The constraint is infrastructure separation: air cooled and hydro cooled hardware need different physical deployment environments because they have opposite cooling requirements. S19 Pro and S21 air cooled units run in standard airflow managed rooms. The S23e Hyd 2U runs in liquid cooling loops. Shared facility, separate cooling zones, unified network and pool configuration. Many professional operations run exactly this hybrid setup to gradually transition from air to hydro cooled infrastructure as budgets allow.

Hydro cooled hardware requires different maintenance than air cooled ASICs. Monthly coolant level checks and quarterly leak inspection at all fittings replace the dust cleaning routine that air cooled miners need. Flow sensors and temperature monitoring through the Antminer management interface catch problems before they cause thermal shutdowns. Annual coolant replacement or refresh depending on your specific fluid specification. Pump maintenance and bearing inspection on the facility side of the loop, not the miner itself. The 2U chassis has no accessible fan bearings to inspect since it relies entirely on external cooling infrastructure. Budget for the facility cooling loop maintenance as a separate line item from the miner itself since the two systems have different failure modes and service requirements.