Mining Server Racks & Cabinets | ASIC Miner Racking Solutions

Server racks and cabinets configured for ASIC mining deployments. Standard 19-inch racks with PDU (Power Distribution Unit) integration, cable management systems, and mounting hardware compatible with both air-cooled and hydro-cooled miners. Proper racking is not optional for operations above 5 miners. Organized racks improve airflow, simplify maintenance access, reduce cable clutter, and allow systematic hot/cold aisle separation that keeps chip temperatures within manufacturer specifications. For hydro miners, racks include plumbed connections for coolant lines. Contact the team for specifications, rack capacity planning, and compatibility with specific ASIC miner models.

5.0
star star star star star
4.97
star star star star star
4.5
star star star star star
Mining Server Racks & Cabinets | ASIC Miner Racking Solutions
मधुमक्खी छत्ता-ग्रिड मधुमक्खी छत्ता-ग्रिड
Filter & Sort

सत्यापित उपकरण

Every unit inspected before dispatch

लोड करने के लिए तैयार

PDU, cabling & mounting pre-installed

क्रिप्टो स्वीकृत

Pay with BTC, ETH, USDT & more

विशेषज्ञ समर्थन

Infrastructure specialists on hand

छोटी बेड़ा अवसंरचना

Professional Mining Infrastructure for Fleets That Don't Need a Container

प्रत्येक माइनिंग ऑपरेशन को पूरी शिपिंग कंटेनर की आवश्यकता नहीं होती। यदि आप 4 से 30 ASIC माइनर्स चला रहे हैं — चाहे वह गैराज, तहखाना, वेयरहाउस यूनिट, या को-लोकेशन स्पेस में हो — तो एक माइनिंग रैक या कैबिनेट आपको बिना पूंजी निवेश या कंटेनर तैनाती के क्षेत्रफल के पेशेवर एकीकृत अवसंरचना समाधान प्रदान करता है। माइनिंग रैक और कैबिनेट में पहले से ही ऊर्जा वितरण, केबल प्रबंधन, और ठंडक की सुविधा शामिल होती है, इसलिए आप खाली शेल्विंग या अस्थायी माउंटिंग फ्रेम से शुरुआत नहीं कर रहे हैं।

फ्लीट रेंज

4–30 एएसआईसी

per rack or cabinet unit

सेटअप समय

<1 दिन

From delivery to first hashrate

Power per Rack

20–120 kW

Depending on model and configuration

शोर कम करना (कैबिनेट)

−10–20 dB

Enclosed cabinets attenuate miner noise


अंतर को समझना

Racks vs Cabinets: What's the Actual Difference?

ये शर्तें अक्सर एक-दूसरे के स्थान पर उपयोग की जाती हैं, लेकिन ये अलग-अलग उपयोग मामलों वाले विशिष्ट उत्पादों का वर्णन करती हैं। यहाँ उनके बीच चयन करने का तरीका है।

खुला-फ्रेम रैक

ओपन एयरफ्लो

An open-frame mining rack is a steel structure with no side panels or doors — miners are exposed to the room environment. This maximises airflow access and simplifies servicing: every machine is immediately reachable without opening enclosures. Racks are typically the right choice for dedicated mining rooms or warehouses where ambient conditions are controlled and access is restricted.

अवरोध मुक्त वायु प्रवाह — सबसे आसान थर्मल प्रबंधन

रखरखाव और स्वैप-आउट के लिए सबसे तेज़ पहुँच

Lower cost than enclosed cabinet equivalents

बाहरी हाइड्रो रेडिएटर्स के साथ जोड़ा जा सकता है

कोई ध्वनि अवसंरेषण नहीं — कमरे में पूर्ण खनिक शोर

No dust or environmental protection

Not suitable for shared or residential spaces

सबसे अच्छा के लिए

समर्पित खनन कक्ष, गोदाम, सह-स्थान स्थान जहाँ नियंत्रित पहुंच और उचित वेंटिलेशन है

Enclosed Cabinet

Sound & Dust Control

एक संलग्न खनन कैबिनेट में स्टील साइड पैनल, फ्रंट दरवाजा, पिछला निकास संरचना, और रैक फ्रेम के चारों ओर ध्वनि अवशोषक फोम या भारी भरे विनाइल लाइनिंग जोड़ी जाती है। इनटेक एयर फ़िल्टर्ड वेंट्स के माध्यम से प्रवेश करता है; गरम निकास एक डक्टेड पिछली चैनल या ऊपर की प्लेनम के माध्यम से बाहर निकलता है। परिणाम: एक स्व-सम्पूर्ण सूक्ष्म जलवायु जो आसपास के क्षेत्र में श्रव्य शोर को पर्याप्त हद तक कम कर देती है और हार्डवेयर को धूल से सुरक्षित रखती है।

−10–20 डेसिबल शोर में कमी बनाम खुला रैक

Dust filtration extends hardware lifespan

स्व-निर्भर वायु प्रवाह — साझा स्थानों में उपयोगी

Lockable enclosure for security

Higher cost than open racks

थोड़ा अधिक जटिल रखरखाव पहुंच

प्रत्यावर्तन के लिए पर्याप्त कक्ष वायु विनिमय आवश्यक है

सबसे अच्छा के लिए

Garages, basements, offices, shared buildings — anywhere noise or dust needs to be contained


What's Pre-Installed

मानक रैक और कैबिनेट अवसंरचना

01

पीडीयू रेल और विद्युत वितरण

High-density PDU rails pre-wired to the enclosure's main input. Individual outlets per miner position. Typically 16A–32A per outlet, with overall circuit protection at the rack/cabinet level.

02

ASIC माउंटिंग फ्रेम्स

Adjustable steel rails pre-set for standard Antminer / WhatsMiner form factor widths. Miners slide in and bolt down without custom fabrication. Compatible with common S19, S21, M50, M60 form factors.

03

Cable Management

Structured power cable routing channels, tie-down points, and cable trays keeping power and network cables separated and organised — critical for airflow and serviceability.

04

Cooling Provisions

Racks: open-frame airflow optimised for through-cooling. Cabinets: filtered intake vents, hot-exhaust rear plenum, optional fan assist, acoustic lining on applicable models.

05

रचनात्मक फ्रेम

Heavy-gauge welded steel construction. Racks with adjustable levelling feet. Cabinets with lockable front/rear doors, removable side panels for maintenance, and optional casters for repositioning.

यह क्यों महत्वपूर्ण है

खुले शेल्फ से पेशेवर खनन स्थापना तक

Most small operators start with ASIC miners stacked on improvised shelving, power cables routed ad-hoc, and no organised airflow. This works — until it doesn't. Improvised setups create uneven airflow that raises intake temperatures across the stack, power distribution that is hard to audit and prone to overloading, and tangled cables that make every maintenance job harder than it needs to be.

एक उद्देश्य-निर्मित खनन रैक या कैबिनेट इन सभी मुद्दों का समाधान एक ही उत्पाद में करता है। स्थिर पंक्ति केSpacing से खनिकों के बीच सही वायु प्रवाह गैप बना रहता है। समर्पित PDU रेलें पावर आवंटन में अनुमान लगाने की आवश्यकता समाप्त करती हैं। संरचित केबल प्रबंधन का मतलब है कि असफल इकाई को बदलना 10 मिनट का काम है बजाय एक घंटे के उलझाने के। और कैबिनेट मॉडल के लिए, वातावरण कमरा शोर में मापन योग्य कमी तुरंत ही जीवन स्तर में सुधार है, जो किसी भी व्यक्ति के लिए स्थान का उपयोग कर रहा हो।

उन ऑपरेटरों के लिए जो कुछ खनिकों से शुरू करके एक महत्वपूर्ण बेड़े की ओर बढ़ रहे हैं, अनौपचारिक से संरचित अवसंरचना की ओर कदम पहला पेशेवर निर्णय है — और रैक और केबिनेट्स यही कदम हैं। जब आप अंततः कंटेनर स्केल तक पहुंचते हैं, तो बदलाव आसान होता है: आपके खनिक रैक से बाहर निकल कर उसी माउंटिंग हार्डवेयर का उपयोग करके कंटेनर फ्रेम में चले जाते हैं।


FAQ

खान्न रैक और कैबिनेट के बारे में आम प्रश्न

Mining racks and cabinets are purpose-built enclosures designed to house, power and cool ASIC miners. They include mounting rails, integrated PDU strips and airflow management — providing organised, safe and efficient infrastructure for mining operations of any size.

We stock open-frame mining racks, enclosed cabinets and modular shelf systems. Open-frame racks maximise airflow and are ideal for hydro miners. Enclosed cabinets provide dust protection and noise containment. Browse our range or contact us for recommendations.

Capacity depends on the model: open-frame racks typically hold 4-12 miners, while larger enclosed cabinets accommodate up to 20-30 units. Each product listing specifies exact capacity and compatible miner models. Contact us with your fleet details for confirmation.

Yes — our racks feature adjustable mounting rails compatible with standard ASIC form factors including Bitmain Antminer S-series, MicroBT WhatsMiner M-series and Canaan Avalon. Mixed-fleet racks are well supported. Check product specs for exact mounting rail adjustment range.

Our racks include integrated PDU rails with C19/C20 outlets rated for continuous ASIC loads (16A-63A). For per-outlet metering and remote switching, supplemental smart PDUs are available. We size PDU capacity to match your specific miner configuration. Contact us for PDU guidance.

Our racks include cable management channels, tie-down points and structured routing paths. Use short patch cables (0.5-1.5m) from miners to rack-mounted switches, and route power cables along dedicated channels. Proper cable management prevents airflow blockage and simplifies maintenance.

Open-frame racks provide unrestricted airflow — ideal for air-cooled and hydro miners. Enclosed cabinets use hot/cold aisle configurations with directed intake and exhaust. Ensure adequate room ventilation to evacuate 2-5 kW of heat per miner. Hydro racks eliminate indoor heat issues entirely.

Yes — enclosed cabinets with foam-lined panels can reduce noise by 5-15 dB compared to open racks. However, air-cooled ASICs at 75-85 dB are still significant. For true quiet operation, consider hydro-cooled miners or professional hosting at our climate-controlled facilities.

Yes — open-frame racks are suitable for home mining with 1-5 miners if you have dedicated 240V circuits, a ventilated space (garage, basement, utility room) and noise tolerance. For larger setups or noise-sensitive environments, professional hosting at $0.07/kWh is more practical.

Yes — all racks and cabinets ship with free worldwide DDP delivery. No customs duties or import taxes. We ship via DHL, FedEx and UPS with full tracking and insurance. In-stock items dispatch within 1-3 business days.

Yes — we offer custom rack configurations tailored to your specific miner fleet, power requirements and space constraints. Contact our team with your specifications. Custom builds typically carry 4-8 week lead times depending on complexity.

Yes — volume B2B pricing is available with dedicated account management for large rack orders. Contact our B2B team with quantities and specifications. We offer combined rack + miner + hosting packages for complete deployments.

Mining racks are designed for self-installation: assemble the frame, mount PDU rails, position miners on shelf/rails, connect power and Ethernet. No specialised tools required. We provide assembly documentation with every order. For large deployments, we can recommend installation partners.

Our racks use heavy-gauge steel (powder-coated for corrosion resistance) or aluminium for lighter-weight options. Steel racks offer maximum durability and vibration dampening. Aluminium racks are easier to move and suitable for smaller deployments. Both materials are rated for continuous ASIC loads.

Our racks are rated for 200-500 kg per shelf level depending on the model. A typical ASIC miner weighs 12-18 kg, so even fully loaded racks operate well within weight limits. Check product specifications for exact ratings. Ensure your floor surface can support the total loaded weight.

For air-cooled miners, the room must evacuate 2-5 kW of heat per miner. For 10+ miners, industrial ventilation or dedicated HVAC is essential. Open-frame racks need unrestricted airflow on intake and exhaust sides. Hydro-cooled setups route heat externally via radiators, eliminating indoor ventilation requirements.

Hot/cold aisle separates miner intake air (cold aisle) from exhaust air (hot aisle) to prevent recirculation and improve cooling efficiency. Enclosed cabinets support this natively. Open-frame racks achieve it by consistent miner orientation and directed room airflow. This becomes important at 10+ miners.

Yes — start with one rack and add more as your fleet grows. Each rack connects independently to power and networking. The typical upgrade path is: shelf (1-3 miners) to rack (4-12) to cabinet (12-30) to container (60+). We offer volume pricing for phased purchases.

Inspect power connections quarterly, clean dust from PDU outlets, verify mounting hardware tightness, and replace any worn cable ties. Enclosed cabinets need air filter checks monthly. Well-maintained racks last 10+ years. See our FAQ for maintenance checklists.

Our team helps you choose the right rack configuration for your miners, space and growth plans. Contact us via WhatsApp, email or phone. Visit our FAQ for instant answers to common infrastructure questions.

Ready to Build Your Mining Rack Setup?

ऊपर हमारे खनन रैक और कैबिनेट की पूरी रेंज ब्राउज़ करें। क्या आप सुनिश्चित नहीं हैं कि आपकी सेटअप के लिए रैक या कैबिनेट सही है, या कि कोई कंटेनर पहले से ही उचित हो सकता है? हमारी टीम आपकी फ़्लीट की साइज, साइट की स्थितियों और विकास योजनाओं के आधार पर सलाह देने में खुशी महसूस करेगी।