In Stock

Bitmain

Bitmain Antminer L11 Hyd 2U (35GH)

Model: Antminer L11 Hyd 2U

New

35 GH/s hydro cooled Scrypt miner in a 2U rack mount chassis for Litecoin (LTC) and Dogecoin (DOGE) merged mining. Bitmain's highest density Scrypt product, packing 21 units per 42U rack to produce 735 GH/s aggregate hashrate, over three times the per rack output of the 3U L11 HU6 variant. 5,775W at 0.165 J/MH efficiency. Water cooling reduces noise to 50 dB, a 25 dB reduction from air cooled Scrypt miners that matters significantly in multi tenant data centers or facilities where staff work near hardware. 380 to 480V three phase industrial power. Shares 2U format with the older L9 Hyd 2U, allowing mixed rack deployment on shared water manifolds for facilities upgrading gradually. Released December 2025. Mines Scrypt coins including LTC, DOGE, BEL, PEP, DGB. 445 x 88 x 670 mm at 20.5 kg. Ships with PSU, Bitmain factory warranty, and free DDP worldwide from MillionMiner. Price: $10,989.

35 GH/s 5775W Scrypt 165 J/TH

Select Availability

Quantity

Total Price

$10,989.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bank Transfer | BTC | ETH | USDT

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Hashrate

35 GH/s

Power

5775 W

Efficiency

165.00 J/GH

Noise

50 dB

Estimated Mining Returns

Based on current BTC price & network difficulty. Indicative only.

Period Daily Weekly Monthly
Income
$19.72 $138.04 $591.60
Electricity
-$6.93 -$48.51 -$207.90
Profit
$12.79 $89.53 $383.70

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.

Full Specifications

Hashrate 35 GH/s
Power Consumption 5775 W
Efficiency 165.00 J/GH
Algorithm Scrypt
Model Antminer L11 Hyd 2U
Release Year Dec 2025
Noise Level 50 dB
Dimensions 445 x 88 x 670mm
Weight 20 g
Voltage 380 - 480v
Interfaces Ethernet
Operating Temp 5 - 45 °C
Humidity 5 - 95 %
Cooling Type Hydro
Rack Format 2U

What's in the Box

Antminer L11 Hyd 2U
Power supply unit (PSU)
Power cables
Quick start guide

Contents may vary by batch. Exact items listed in order confirmation.

Quick Setup

1

Connect PSU to miner and plug into the outlet

2

Connect ethernet cable to your router or switch

3

Find miner IP via router admin or IP scanner tool

4

Open web interface, enter pool URL and wallet — start mining

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
star star star star star

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso made-in-germany trustpilot
google-review

Get a Quote for the Bitmain Antminer L11 Hyd 2U (35GH)

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Product Details

Bitmain Antminer L11 Hyd 2U 35 GH/s Hydro Cooled Rack Mount Scrypt Miner for Litecoin and Dogecoin: Specifications, Density Economics, and Deployment Guide

The Bitmain Antminer L11 Hyd 2U is the density leader of Scrypt mining
hardware. 35 GH/s of Scrypt hashrate at 5,775W in a 2U rack mount chassis with closed loop
water cooling packs more Scrypt hashrate per rack unit than any alternative on the market in
early 2026. Released December 2025, this represents Bitmain's latest generation Scrypt silicon
at 0.165 J/MH efficiency (equivalently 165 J/GH).
Rack density math: a standard 42U rack holds 21 L11 Hyd 2U units, producing 735 GH/s
aggregate Scrypt hashrate at approximately 121 kW per rack. Compare against the larger 3U
L11 HU6 variant: only 7 units fit per 42U rack, producing 231 GH/s aggregate. The 2U hydro
variant delivers more than three times the Scrypt hashrate per rack of floor space. For facilities
where physical floor space is the binding constraint rather than electrical capacity, this density
advantage is decisive.
The trade off is operational complexity. 21 units per rack means three times more water quick
disconnect fittings to inspect and maintain, three times more power cords to manage, three
times more individual chassis to monitor, and three times more firmware update cycles to
coordinate. For operations optimizing purely for per unit maintenance simplicity, the 3U L11 HU6
with fewer units per rack presents a different optimization target.
Water cooling enables two distinct advantages beyond just thermal management. First: the 2U
form factor would be thermally impossible with air cooling at 5,775W per unit continuous draw.
Air cooling requires more surface area and airflow path than a 2U chassis can provide at this
power density. Hydro cooling makes the density class physically possible. Second: noise drops
to 50 dB, compared to 75 dB typical for air cooled Scrypt miners like the L11 Pro or L9 series.
The 25 dB gap represents roughly half the perceived sound intensity and opens deployment
options unavailable to air cooled hardware. Multi tenant colocation facilities, data centers with
mixed workloads, research facilities, and operations where staff work near hardware regularly all
benefit meaningfully from the noise reduction.
Water cooling infrastructure requirements: closed loop water circulation using off the shelf
pumps, standard plumbing fittings, and common water glycol coolant. Dry coolers, heat
exchangers, and chillers size to the facility's total thermal load. The 5,775W per unit thermal
output (approximately 19,715 BTU per hour per unit) scales proportionally. A fully loaded 42U
rack producing 121 kW thermal output requires approximately 413,300 BTU per hour heat
rejection capacity.
The L11 Hyd 2U shares its 2U form factor exactly with the previous generation L9 Hyd 2U (27
GH/s Scrypt). This allows mixed rack deployment on shared water manifolds for facilities
upgrading gradually from L9 to L11 generation hardware. Existing L9 installations can introduce
L11 units incrementally without tearing out the water cooling infrastructure, replacing individual
units as capital becomes available or as L9 warranty periods expire.
Scrypt merged mining protocol is a key economic feature. One fleet simultaneously mines
multiple Scrypt compatible cryptocurrencies through supporting pools without splitting hashrate
across algorithms. Primary targets: Litecoin (LTC) with the largest Scrypt network, Dogecoin
(DOGE) with strong retail interest and merged mining support. Secondary targets included in
the mining reward stream: Bellscoin (BEL), PepeCoin (PEP), DigiByte Scrypt chain (DGB),
Luckycoin (LKY), Catcoin (CAT), DingoCoin (DINGO), Auroracoin (AUR), and smaller Scrypt
chains. Major pools supporting merged mining include F2Pool (26.7 percent Scrypt network
share), ViaBTC (29.0 percent), AntPool (17.8 percent), EMCD (6.3 percent).
Profitability economics depend heavily on electricity rate. ASIC Miner Value data at AED 0.53
per kWh (approximately $0.144 per kWh residential rates) shows negative daily margins
reflecting current Scrypt market conditions. MillionMiner's $0.08 per kWh onsite calculator
shows $22.79 daily revenue, $11.09 electricity, $11.70 net daily profit per unit. At $0.04 per kWh
negotiated industrial rates: $5.54 daily electricity, netting $17 daily profit per unit. Economic
viability requires industrial electricity below $0.10 per kWh for reliably positive returns. ROI
timelines vary significantly based on LTC and DOGE price trajectory. Model conservatively
against current network difficulty rather than assuming favorable coin price movements.
380 to 480V three phase commercial or industrial power. At 415V three phase: approximately
13.5 amps per phase continuous draw. At 480V three phase: approximately 11.7 amps per
phase. Fits within standard 20 amp commercial breakers. Bitmain APW series hydro PSU
included.
445 x 88 x 670 mm at 20.5 kg per unit. Weight planning matters for fully loaded racks: 21 units
totals approximately 430 kg plus water and infrastructure weight. Verify rack weight capacity and
facility floor loading before deployment. 5 to 45 degrees Celsius operating range at 5 to 95
percent humidity. Ethernet 10/100M management through Antminer firmware. Price at
MillionMiner: $10,989. Ships with PSU, Bitmain factory warranty, and free DDP delivery
worldwide.

Bitmain Antminer L11 Hyd 2U 35 GH/s: The Density Leader in Scrypt Mining

The L11 Hyd 2U redefines Scrypt mining density. 35 GH/s of Scrypt
hashrate in a 2U rack mount chassis allows 21 units per 42U rack, producing 735 GH/s
aggregate. Compare against the larger 3U L11 HU6 which fits only 7 units per 42U rack at 231
GH/s aggregate. The 2U variant delivers more than three times the Scrypt hashrate per rack of
floor space. The trade off is three times more water connections, power connections, and
individual units to manage per rack.
Water cooling enables two specific advantages. First: the 2U form factor would be thermally
impossible with air cooling at 5,775W per unit, so density at this level requires hydro. Second:
noise drops to 50 dB, compared to 75 dB typical for air cooled Scrypt hardware. The 25 dB gap
represents roughly half the perceived sound intensity, which matters in multi tenant colocation
facilities, data centers with mixed workloads, and operations where staff work near mining
hardware regularly.
Released December 2025, the L11 Hyd 2U is the latest generation Bitmain Scrypt silicon at
0.165 J/MH efficiency (165 J/GH). Scrypt merged mining protocol means one fleet
simultaneously mines Litecoin (LTC), Dogecoin (DOGE), and other Scrypt compatible coins
through supporting pools without splitting hashrate across algorithms. Current ASIC Miner Value
profitability data at AED 0.53 per kWh (approximately $0.144 per kWh) shows negative daily
margins, reflecting Scrypt market conditions in early 2026 at consumer residential electricity
rates. At MillionMiner's $0.08 per kWh onsite calculator: $22.79 daily revenue, $11.09 electricity,
$11.70 net daily profit. Economic viability requires industrial electricity below $0.10 per kWh for
positive returns.
380 to 480V three phase. 445 x 88 x 670 mm at 20.5 kg. Price at MillionMiner: $10,989.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Antminer L11 Hyd 2U 35 GH/s Scrypt Miner LTC DOGE

Bitmain's highest density Scrypt miner. 35 GH/s in a 2U rack mount
chassis, packing 21 units per 42U rack to produce 735 GH/s aggregate, over three times the per
rack output of the 3U L11 HU6 variant (231 GH/s per rack). Water cooled at 50 dB, a 25 dB
reduction versus air cooled Scrypt hardware that matters in multi tenant data centers. 5,775W at
0.165 J/MH (165 J/GH) efficiency on 380 to 480V three phase. Mines Scrypt coins through
merged mining protocol: Litecoin (LTC) and Dogecoin (DOGE) simultaneously on one fleet, with
Bellscoin, PepeCoin, DigiByte Scrypt chain, and other Scrypt coins also compatible. Same 2U
format as the L9 Hyd 2U for mixed rack deployment during gradual fleet upgrades. 445 x 88 x
670 mm at 20.5 kg. 5 to 45 degrees Celsius operating range.

35 GH/s Scrypt Density Leader

21 units per 42U rack produce 735 GH/s aggregate, over three times the per rack output of the 3U L11 HU6 variant. Highest Scrypt density available.

50 dB Hydro Noise Advantage

25 dB quieter than air cooled Scrypt miners. Opens deployment in multi tenant data centers and facilities where staff work near hardware.

Merged Mining LTC and DOGE

Scrypt protocol mines Litecoin and Dogecoin simultaneously on one fleet plus BEL, PEP, DGB, and other Scrypt chains through supporting pools.

FAQ

Frequently Asked Questions

The L11 Hyd 2U produces 35 GH/s of Scrypt hashrate at 5,775W continuous power draw and 0.165 J/MH efficiency (equivalently 165 J/GH). Released December 2025 as Bitmain's latest generation hydro cooled Scrypt silicon in the compact 2U form factor. The 35 GH/s figure represents the highest Scrypt hashrate per rack unit currently available from any manufacturer, making the L11 Hyd 2U the density leader for Scrypt mining in early 2026.

Same generation silicon, different chassis form factor. L11 Hyd 2U: 35 GH/s per unit at 5,775W in 2U. L11 HU6 (3U): similar per unit performance but in 3U rack mount. Critical difference is rack density. A 42U rack holds 21 L11 Hyd 2U units producing 735 GH/s aggregate, versus 7 L11 HU6 units producing roughly 231 GH/s aggregate. The 2U variant delivers more than three times the Scrypt hashrate per rack of floor space. Trade off: three times more water connections, power cords, and individual units to maintain per rack. Optimize for density with 2U, or for per unit simplicity with 3U.

Two scenarios favor high density hardware. First: facilities with limited physical floor space where every square meter of real estate carries meaningful cost, common in urban colocation facilities or data centers operating under space constraints. Second: facilities scaling Scrypt operations within existing electrical capacity ceilings where adding more racks means repurposing existing space rather than building new facility. The L11 Hyd 2U extracts maximum Scrypt hashrate from available floor space. For operations with unlimited floor space and unlimited electrical capacity, density advantages matter less.

All Scrypt proof of work cryptocurrencies. Primary targets through merged mining: Litecoin (LTC) with the largest Scrypt network, and Dogecoin (DOGE) with strong retail interest. Merged mining means one fleet simultaneously contributes hashrate to both networks without splitting output. Secondary Scrypt coins supported through major pools: Bellscoin (BEL), PepeCoin (PEP), DigiByte Scrypt chain (DGB), Luckycoin (LKY), Catcoin (CAT), DingoCoin (DINGO), Auroracoin (AUR), GoldCoin (GLC), Junkcoin (JKC), and smaller forks. Revenue from all simultaneously mined chains streams into the same wallet addresses. Quai (QUAI) at 722 QUAI daily per current ASIC Miner Value data represents emerging Scrypt compatible chain activity.

Merged mining allows identical hashing work to qualify for block rewards on multiple compatible networks simultaneously. For Scrypt, this means a single fleet submitting hashes to a merged mining pool earns LTC, DOGE, BEL, and other Scrypt rewards without splitting computational effort. Economic effect: Dogecoin rewards are effectively free additional revenue on top of Litecoin mining, because the same work qualifies for both. Most operators running Scrypt hardware treat DOGE rewards as bonus yield on primary LTC mining operations. Pool configuration automatically handles the merged mining protocol through supporting pools like F2Pool, ViaBTC, AntPool, and EMCD.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 13.5 amps per phase continuous draw at 5,775W. At 480V three phase: approximately 11.7 amps per phase. Fits within standard 20 amp commercial breakers with headroom. Not suitable for standard residential or small commercial electrical systems. European, Middle Eastern, and industrial Asian facilities at 380 to 415V three phase have direct deployment paths. North American industrial facilities at 480V three phase also deploy directly.

Closed loop water circulation with standard industrial components. Required: circulation pumps sized for total fleet flow rate, standard plumbing fittings, water glycol coolant mixture, external heat rejection through dry coolers or water to water heat exchangers, and inline filtration. Coolant volume scales roughly 2 to 4 liters per unit plus system reservoir capacity. Each L11 Hyd 2U adds approximately 19,715 BTU per hour of thermal load. A fully loaded 42U rack producing 121 kW thermal output requires roughly 413,300 BTU per hour heat rejection capacity. Uses standard data center cooling equipment from any industrial supplier.

Yes. The 2U form factor is identical between generations, with same water connector geometry, same chassis dimensions, same rack mounting hardware, and same water manifold compatibility. Mixed rack deployment allows facilities to upgrade gradually from L9 (27 GH/s) to L11 (35 GH/s) generation hardware as capital becomes available or as L9 warranty periods expire. No infrastructure changes required when introducing L11 units into existing L9 hydro installations. Fleet management through standard Antminer firmware handles mixed generation deployment transparently.

Highly electricity rate dependent. MillionMiner's $0.08 per kWh onsite calculator shows $22.79 daily revenue, $11.09 electricity, $11.70 net daily profit per unit. ASIC Miner Value data at AED 0.53 per kWh (approximately $0.144 per kWh residential rates) shows negative daily margins reflecting current Scrypt market conditions at consumer electricity pricing. At $0.04 per kWh negotiated industrial rates: $5.54 daily electricity, netting roughly $17 daily profit per unit. At $0.07 per kWh typical industrial rates: $9.71 daily electricity, netting roughly $13 daily. Economic viability requires industrial electricity below $0.10 per kWh for reliably positive returns. Scrypt profitability varies significantly with LTC and DOGE price movements.

50 dB for the L11 Hyd 2U versus 75 dB typical for air cooled Scrypt miners. The 25 dB gap represents roughly half the perceived sound intensity to human ears. Practical implications: multi tenant colocation facilities can deploy L11 Hyd 2U hardware without disrupting neighboring tenant operations, data centers with mixed workloads avoid acoustic interference with staff areas, research facilities and test environments can operate mining hardware alongside sensitive equipment, and operations where staff work near hardware for extended periods reduce occupational noise exposure significantly.

Not practically. Despite the quieter 50 dB acoustic profile, the L11 Hyd 2U requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure with pumps and heat rejection capacity, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V single phase circuits. For residential Scrypt mining, air cooled models like smaller Antminer L series units or the L9 are more appropriate product matches. The L11 Hyd 2U is strictly industrial hardware for professional mining facilities.

Industrial deployment with three phase power and water cooling infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission water cooling loop including pumps, plumbing, dry coolers, and initial coolant fill. Step three: rack mount L11 Hyd 2U units in standard 19 inch racks and connect water inlet/outlet fittings to your manifold system. Verify zero leaks before energizing. Step four: connect PSU power and Ethernet management. Step five: power on, allow coolant flow to stabilize, find each miner IP through DHCP, configure Scrypt merged mining pool URL and LTC/DOGE wallet addresses through Antminer web interface, verify hashrate reaches 34 to 35 GH/s within 10 to 15 minutes per unit.

Major Scrypt merged mining pools include F2Pool (26.7 percent Scrypt network share), ViaBTC (29.0 percent with merged mining support), AntPool (17.8 percent), and EMCD (6.3 percent). All support simultaneous LTC and DOGE mining plus secondary Scrypt chain rewards. Pool fee comparison: F2Pool PPLNS at 4 percent or PPS at 4 percent, ViaBTC PPLNS at 2 percent, AntPool PPS at 3 percent, EMCD PPLNS at 1.5 percent (with 10 percent discount via AMV10 code per ASIC Miner Value listing). For fleet deployments above 1 PH/s Scrypt (equivalent to 28+ L11 Hyd 2U units), negotiated pool fees below standard rates typically become available.

Water cooling maintenance. Weekly visual inspection of all fittings for leaks or corrosion. Monthly coolant quality testing (pH within spec, particulate levels minimal). Every 12 to 24 months full coolant replacement depending on fluid chemistry. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Higher unit count per rack (21 units versus 7 in the 3U variant) increases cumulative maintenance cycles per rack but individual unit failures have smaller fleet impact. Budget 3 to 5 percent of acquisition cost annually per unit for coolant, filtration, and spare parts.

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 5.775 kW: electricity at $4,047 at $0.08 per kWh, $3,540 at $0.07 per kWh industrial rates, or $2,023 at $0.04 per kWh negotiated industrial rates. Coolant maintenance: $100 to $300 per unit annually. Spare parts: $200 to $400 annually per unit. 3 year TCO per unit at $0.07 per kWh: approximately $13,000 hardware and infrastructure plus $10,620 electricity.

Yes. MillionMiner operates managed hosting facilities with three phase industrial power and water cooling infrastructure capable of supporting L11 Hyd 2U deployments. Hosted deployment eliminates facility infrastructure CapEx. Professional hosting at negotiated industrial rates often beats self hosting for Scrypt miners without access to industrial electricity below $0.08 per kWh, because Scrypt profitability margins are tight at standard commercial rates. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

Bitmain's factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document coolant testing schedule and maintenance logs to protect warranty coverage. MillionMiner routes claims through direct Bitmain channels for faster resolution than secondary market purchases provide.

Standard Antminer firmware provides the same web interface, pool configuration format, and management API as other Bitmain miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover L11 Hyd 2U units automatically through network scanning. Additional monitoring metrics for hydro operation (coolant flow rate, inlet/outlet temperatures) appear in hydro specific dashboards. Mixed brand and cooling type fleets handle through unified dashboards, with Scrypt specific metrics tracked alongside SHA-256 or Equihash operations if running multi algorithm mining facilities.

Depends on electricity rate and LTC/DOGE price outlook. Current economics per MillionMiner onsite calculator show $11.70 net daily profit at $0.08 per kWh, so industrial facilities with rates below $0.10 per kWh maintain healthy margins. ASIC Miner Value data at consumer residential rates shows negative margins, indicating Scrypt mining at residential electricity is not economically viable at current LTC/DOGE prices. Dogecoin retail interest and Litecoin network effects continue to support Scrypt mining economics but margins have compressed over multiple years as network difficulty has grown faster than coin prices. Model conservatively against current network conditions rather than assuming favorable future price movements.

Within Scrypt: the previous generation L9 Hyd 2U at 27 GH/s (same 2U chassis, compatible with shared water manifolds), air cooled L11 Pro for facilities without hydro infrastructure, and older L7 series hardware at budget tier pricing. Cross algorithm diversification options: Antminer S21 XP at 270 TH/s or Whatsminer M70S+ at 244 TH/s for SHA-256 Bitcoin mining, Antminer KS7 at 45 TH/s for KHeavyHash Kaspa mining, Antminer Z15 at 420 kSol/s for Equihash Zcash mining, Goldshell HS5 series for Handshake (HNS) mining. For multi algorithm fleet diversification, the L11 Hyd 2U represents the Scrypt component of a balanced portfolio. MillionMiner's ASIC hosting service accepts L11 Hyd 2U units at negotiated industrial electricity rates.

Get a Quote