In Stock

Bitmain

Bitmain Antminer S21e XP Hydro (860Th/s)

Model: Antminer S21e XP Hydro

New

Bitmain's prior generation 3U petahash class hydro cooled Bitcoin miner, delivering 860 TH/s SHA-256 hashrate at 11,180W power draw and 13 J/TH efficiency. Model U3S21EXPH announced September 2024 with shipping from January 2025. Positioned directly below the current generation S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) at significantly lower acquisition cost, making the S21e XP Hyd 3U the strongest per dollar of hashrate value play in the 3U petahash tier. 380 to 415V three phase industrial power with approximately 24 amp maximum current draw. 3U rack mount format in 900 x 486 x 132 mm chassis at approximately 50 kg deployed weight. 50 dB chassis noise (external cooling infrastructure separate). 20 to 50 degrees Celsius operating range. External closed loop hydro cooling with dry cooler or heat exchanger infrastructure rated for 11.2 kW thermal load per unit. ±3% hashrate tolerance means real output 834 to 886 TH/s. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.

860 TH/s 11180W SHA-256 13 J/TH

Select Availability

Quantity

Total Price

$11,649.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bank Transfer | BTC | ETH | USDT

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Hashrate

860 TH/s

Power

11180 W

Efficiency

13.00 J/TH

Noise

50 dB

Estimated Mining Returns

Based on current BTC price & network difficulty. Indicative only.

Period Daily Weekly Monthly
Income
$32.22 $225.54 $966.60
Electricity
-$21.47 -$150.29 -$644.10
Profit
$10.75 $75.25 $322.50

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 08, 2026. Estimates at $0.08/kWh.

Full Specifications

Hashrate 860 TH/s
Power Consumption 11180 W
Efficiency 13.00 J/TH
Algorithm SHA-256
Model Antminer S21e XP Hydro
Release Year Jan 2024
Noise Level 50 dB
Dimensions 900 x 486 x 132mm
Weight 18 kg
Voltage 380-415V
Interfaces Ethernet 10/100M
Operating Temp 20 - 50 °C
Humidity 10 - 90 %
Cooling Type Hydro
Rack Format 3U

What's in the Box

Antminer S21e XP Hydro
Power supply unit (PSU)
Power cables
Quick start guide

Contents may vary by batch. Exact items listed in order confirmation.

Quick Setup

1

Connect PSU to miner and plug into the outlet

2

Connect ethernet cable to your router or switch

3

Find miner IP via router admin or IP scanner tool

4

Open web interface, enter pool URL and wallet — start mining

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Product Details

Bitmain Antminer S21e XP Hydro 860 TH/s 3U Prior Generation Hydro Cooled Bitcoin Miner: Complete Specifications, Value Positioning, and Deployment Analysis

The Bitmain Antminer S21e XP Hydro 3U at 860 TH/s is the prior generation petahash class 3U rack mount hydro Bitcoin miner, now occupying the value position in Bitmain's 3U product lineup as the current generation S23 Hyd 3U captures flagship status. Official Bitmain model number U3S21EXPH, announced September 2024 with batch shipping from January 2025. 860 TH/s SHA-256 hashrate at 11,180W continuous power draw and 13 J/TH efficiency. ±3% hashrate tolerance means real world output ranges 834 to 886 TH/s. Built on SEAL02 silicon at Bitmain's efficiency tier preceding the S23 generation chips. Market positioning has shifted meaningfully since launch. Upon September 2024 announcement, the S21e XP Hyd 3U represented Bitmain's highest hashrate single unit Bitcoin miner. The January 2026 launch of the S23 Hyd 3U at 1.16 PH/s and 9.5 J/TH captured the flagship position, repositioning the S21e XP Hyd 3U as the value play in the 3U petahash tier. MillionMiner pricing at $11,649 sits in the mid range of market pricing for this unit, with OneMiners showing $10,899 (53 percent off the $23,230 original MSRP) reflecting the legacy inventory pricing pressure on prior generation hardware. The acquisition cost to efficiency tradeoff defines the purchase decision. Compared to S23 Hyd 3U (1,160 TH/s at 11,020W and 9.5 J/TH): the S23 delivers 35 percent more hashrate and 27 percent better efficiency, typically at 2 to 3 times the acquisition cost. For a 10 unit fleet deployment, the arithmetic depends on electricity rate and deployment horizon. At $0.04 per kWh industrial hosting over 3 years, the S21e XP Hyd 3U savings on acquisition typically outweigh lifetime electricity differential from lower efficiency. At $0.08 per kWh commercial rates over 3 years, the efficiency gap compounds into electricity cost differences that favor the newer hardware despite higher acquisition cost. Per rack deployment math: 14 S21e XP Hyd 3U units per 42U rack produce 12.04 PH/s aggregate at approximately 156 kW total power draw. Same rack format but approximately 4.2 PH/s less aggregate hashrate than 14 S23 Hyd 3U units at the same power budget. Per 100 kW industrial electrical panel: approximately 8 to 9 S21e XP Hyd 3U units producing 6.88 to 7.74 PH/s, versus 9 S23 Hyd 3U units producing 10.44 PH/s at the same power budget. Infrastructure requirements are identical to the current S23 Hyd 3U. 380 to 415V three phase industrial power service through LP34 industrial connector per Bitmain specification. At 415V three phase: approximately 15 amps per phase continuous, 25 amps per phase at peak. At 380V: approximately 17 amps per phase continuous, 29 amps at peak. Maximum current draw per BT-Miners documentation: approximately 24 amps per unit. Requires dedicated 32 amp three phase breakers minimum. LP34 industrial connector requirement excludes single phase or residential deployment. External closed loop water cooling infrastructure matches the S23 Hyd 3U requirements. Each unit generates approximately 11.2 kW thermal load (38,144 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for aggregate thermal load, inline particulate filtration, automated flow monitoring, and temperature management. Multi unit deployments scale cooling infrastructure proportionally through manifold distribution with individual isolation valves for unit level maintenance access without system shutdown. Operating temperature specification: 20 to 50 degrees Celsius ambient operating range at 10 to 90 percent humidity. Inlet water temperature constraints apply per Bitmain's hydro cooled hardware platform specifications. 50 dB chassis noise reflects the absence of cooling fans. External cooling infrastructure adds separate acoustic signature depending on pump, dry cooler, and facility design. Professional hydro cooled mining facilities isolate miner deployment space from cooling plant locations to manage total acoustic footprint. Physical specifications: 900 x 486 x 132 mm 3U rack mount chassis compatible with 19 inch server racks. Verify rack depth capability before ordering (900 mm chassis depth exceeds standard 1000 mm rack depth with minimal clearance, may require deeper industrial racks). Standard Bitmain Ethernet 10/100M management with firmware compatibility across Foreman, Awesome Miner, Hive OS, and Braiins OS+ fleet management tools. Same firmware codebase shares updates with S21 and S23 generation hydro hardware. Profitability analysis in April 2026 reflects the value positioning. Mining Now February 2026 data at $0.07 per kWh: $30.81 daily Bitcoin revenue, $18.78 electricity, $12.03 daily net profit. MillionMiner $0.08 per kWh onsite calculator: $28.02 daily revenue, $21.47 electricity, $6.55 daily net. ASIC Miner Value at $0.10 per kWh: $7.26 daily profit. OneMiners May 2025 data at $0.01 per kWh aggressive hosting rates: $40 to $50 daily earnings, averaging $44. ROI estimates 906 to 1,850 days per Mining Now at $0.07 per kWh, compressed to approximately 12 months at $0.04 per kWh hosting per OneMiners. At BTC prices above $160,000, daily profit projections improve meaningfully. Ships with PSU, 365 day Bitmain factory warranty, and free DDP worldwide delivery from MillionMiner including customs clearance.

Bitmain Antminer S21e XP Hydro 860 TH/s 3U: The Value Play in the Petahash

The S21e XP Hydro 3U is Bitmain's prior generation petahash class 3U
rack mount hydro miner, now positioned as the strongest per dollar of hashrate value play in the
3U tier as the current generation S23 Hyd 3U captures the flagship position. 860 TH/s SHA-256
hashrate at 11,180W power draw and 13 J/TH efficiency. Bitmain model number U3S21EXPH,
announced September 2024 with batch shipping from January 2025.
Positioning math matters for acquisition decisions. Compared to the current generation S23 Hyd
3U (1,160 TH/s at 11,020W and 9.5 J/TH): the S23 Hyd 3U delivers 35 percent more hashrate
and 27 percent better efficiency, but typically commands 2 to 3 times the acquisition price. For
operators with industrial electricity rates below $0.04 per kWh where electricity represents a
smaller share of total operational cost, acquisition cost savings on the S21e XP Hyd 3U
outweigh efficiency penalty over typical deployment horizons. At $0.08 per kWh commercial
rates, the efficiency gap compounds faster and the S23 Hyd 3U typically wins lifetime
economics.
Per rack economics: 14 S21e XP Hyd 3U units per 42U rack produce 12.04 PH/s at 156 kW. 14
S23 Hyd 3U units per 42U rack produce 16.24 PH/s at 154 kW. Same rack space, same power
budget, 35 percent more hashrate on the newer generation hardware. The choice depends
entirely on acquisition cost differential at your supplier pricing.
Infrastructure requirements mirror the S23 Hyd 3U. 380 to 415V three phase through LP34
industrial connector, approximately 24 amp maximum current draw. External closed loop hydro
cooling with dry cooler or heat exchanger infrastructure. 20 to 50 degrees Celsius operating
range (inlet water temperature constraints apply). 50 dB chassis noise (external cooling
infrastructure adds separate signature).
Real world profitability: OneMiners May 2025 data at $0.01 per kWh hosting: $40 to $50 daily,
averaging $44. Mining Now February 2026 at $0.07 per kWh: $30.81 daily revenue, $18.78
electricity, $12.03 daily net. ROI 12 months at $0.04 per kWh hosting per OneMiners.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Bitmain Antminer S21e XP Hydro 860 TH/s 3U Rack Mount Bitcoin Miner

Bitmain's prior generation 3U petahash class hydro Bitcoin miner at 860
TH/s, 11,180W, and 13 J/TH efficiency. Model U3S21EXPH announced September 2024,
shipping from January 2025. Now positioned as the value play in the 3U petahash tier at
significantly lower acquisition cost than the current generation S23 Hyd 3U (1.16 PH/s at 9.5
J/TH). For operators with industrial electricity below $0.04 per kWh where efficiency matters less
than acquisition cost, the S21e XP Hyd 3U delivers strong per dollar of hashrate economics.
380 to 415V three phase through LP34 industrial connector, approximately 24 amp maximum
draw. 3U rack format at 900 x 486 x 132 mm. 50 dB chassis noise. 20 to 50 degrees Celsius
operating range. Real world profitability per OneMiners May 2025 at $0.01 per kWh hosting: $40
to $50 daily, averaging $44. Mining Now February 2026 at $0.07 per kWh: $12.03 daily net. ROI
12 months at $0.04 per kWh hosting.

860 TH/s Petahash Class Value Play

Prior generation 3U rack mount at 35 percent lower hashrate than S23 Hyd 3U but typically 50 to 70 percent lower acquisition cost. Value pick for the petahash tier.

13 J/TH in 3U Rack Mount Format

Same 3U chassis format as S23 Hyd 3U. 900 x 486 x 132 mm. 14 units per 42U rack deliver 12.04 PH/s aggregate.

LP34 Three Phase Industrial Only

380 to 415V three phase through LP34 industrial connector. 24 amp maximum current draw. Strictly professional data center deployment.

Request a Bitcoin Miner Hosting Quote

4.7
star star star star star

4.7/5 Verified on Trustpilot

  • envelope 30,000+ miners hosted since 2020
  • timer Trusted by 1,200+ customers globally
iso made-in-germany trustpilot
google-review

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

miner

Miner

hosting

Hosting

FAQ

Frequently Asked Questions

860 TH/s of SHA-256 hashrate at 11,180W continuous power draw and 13 J/TH efficiency. Bitmain's ±3% hashrate tolerance means real world output ranges 834 to 886 TH/s. This is Bitmain's prior generation 3U petahash class hydro miner, positioned below the current S23 Hyd 3U (1.16 PH/s at 9.5 J/TH) but at meaningfully lower acquisition cost reflecting the legacy inventory positioning. Official Bitmain model number U3S21EXPH.

Acquisition cost to deployment economics. The S23 Hyd 3U delivers 35 percent more hashrate and 27 percent better efficiency but typically commands 2 to 3 times the per unit acquisition cost. For operators with industrial electricity rates below $0.04 per kWh where electricity represents a smaller share of total operational cost, the S21e XP Hyd 3U acquisition savings outweigh lifetime efficiency penalty over typical 3 year deployment horizons. Scenarios favoring the S21e XP Hyd 3U: industrial hosting at $0.04 per kWh or lower, shorter deployment horizons (1 to 2 years), hardware budget constraints prioritizing unit count over per unit efficiency, fleet expansion alongside existing S21 series deployments, and speculative positioning where current BTC prices support strong margins even on less efficient hardware.

U3S21EXPH is Bitmain's official product model number for the S21e XP Hyd 3U, confirmed through ASIC Miner Value launch documentation and Kryptex Pool specifications. The "U3" prefix denotes the 3U rack mount form factor. Announced September 2024, began batch shipping from January 2025. MillionMiner's January 2024 release date listing reflects a documentation error (verified against multiple independent distributor sources).

Standard 3U rack mount chassis at 900 x 486 x 132 mm. Compatible with 19 inch server racks and industrial mining facility cabinets. The 900 mm chassis depth requires minimum 1000 mm rack depth for proper cable management, and 1200 mm rack depth provides comfortable cable and cooling access. Most dedicated mining facilities and data centers use 1000 mm or 1200 mm racks. Shallower 600 mm or 750 mm racks cannot accommodate this hardware. Verify facility rack inventory before committing to large fleet orders.

380 to 415V three phase industrial power service through LP34 industrial connector. At 415V three phase: approximately 15 amps per phase continuous, 25 amps per phase at peak. At 380V: approximately 17 amps per phase continuous. Maximum current draw per Bitmain documentation: approximately 24 amps. Requires dedicated 32 amp three phase breakers minimum for reliable operation. LP34 industrial connector requirement excludes any single phase commercial or residential deployment. Strictly industrial hardware for professional data center and dedicated mining facility deployment.

External closed loop water cooling system with substantial thermal capacity. Each unit generates approximately 11.2 kW thermal load (38,144 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for total thermal load, inline particulate filtration, automated flow monitoring, and temperature management at inlet and outlet points. Multi unit deployments scale cooling infrastructure proportionally through manifold distribution with individual unit isolation valves for maintenance access. Budget $10,000 to $40,000 per rack for hydro cooling infrastructure depending on fleet size and existing facility capability.

Form factor and density tradeoffs against standalone alternatives. S21e XP Hyd 3U (this product): 860 TH/s at 11,180W and 13 J/TH in 3U rack format. S21 XP Hydro 473TH: 473 TH/s at 5,676W and 12 J/TH in compact standalone. S21+ Hydro 395TH: 395 TH/s at 5,925W and 15 J/TH in compact standalone. For operators wanting petahash class in 3U rack format at prior generation pricing, the S21e XP Hyd 3U wins. For operators wanting current generation efficiency at 3U format, the S23 Hyd 3U wins. For operators needing universal single phase voltage deployment, the S21 XP Hydro 473TH or S21+ Hydro 395TH single phase options are the relevant choice.

Mixed depending on electricity rate. MillionMiner $0.08 per kWh onsite calculator: $28.02 daily revenue, $21.47 electricity, $6.55 daily net profit. Mining Now February 2026 at $0.07 per kWh: $30.81 daily revenue, $18.78 electricity, $12.03 daily net. ASIC Miner Value at $0.10 per kWh: $7.26 daily profit. OneMiners May 2025 data at aggressive $0.01 per kWh hosting rates: $40 to $50 daily earnings, averaging $44. ROI estimates: 906 to 1,850 days at $0.07 per kWh per Mining Now, compressed to approximately 12 months at $0.04 per kWh industrial hosting per OneMiners.

50 dB chassis noise, effectively silent due to the absence of cooling fans. The external cooling infrastructure generates acoustic signature separately: pumps typically run 45 to 55 dB, dry coolers typically 55 to 70 dB depending on airflow requirements. Professional hydro cooled mining facilities isolate miner deployment space from cooling plant locations to minimize acoustic impact. Total deployment noise depends substantially on cooling infrastructure design and placement relative to miner deployment space.

No. The 11,180W power draw requires 380 to 415V three phase industrial electrical service with LP34 industrial power connector, unavailable in residential settings. The 11.2 kW thermal load requires substantial external water cooling infrastructure impractical for residential installation. The 900 mm chassis depth requires industrial grade rack hardware. Strictly industrial hardware for professional mining facilities and commercial data centers. For home deployment seeking hydro cooling, the Antminer S21+ Hydro 395TH with 100 to 240V universal single phase voltage represents the residential ceiling option.

Industrial deployment with three phase power, LP34 connectors, and hydro cooling infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with LP34 industrial connectors and 32 amp three phase breakers minimum. Step two: install and commission external hydro cooling loop with pumps, plumbing, coolant fill, dry cooler infrastructure, and temperature monitoring. Step three: rack mount units in 19 inch server racks verifying 1000+ mm rack depth. Connect water fittings to manifold system with individual isolation valves. Verify zero leaks before energizing. Step four: connect LP34 power cables and Ethernet management. Step five: power on, allow coolant flow to stabilize, find miner IP through DHCP, configure pool URL and Bitcoin wallet through Bitmain web interface, verify hashrate reaches 834+ TH/s within 15 to 20 minutes per unit.

Industrial hydro cooling maintenance. Weekly visual inspection of water fittings for leaks or corrosion. Monthly coolant quality testing. Every 12 to 24 months full coolant replacement. Quarterly pump and dry cooler inspection including flow rate verification. Inline filter replacement when pressure differential exceeds specification. LP34 connector inspection quarterly. Hashboard failure rates on hydro units run meaningfully lower than air cooled equivalents. As 2025 era legacy hardware, anticipate higher spare parts needs than current generation S23 equivalents. Budget 5 percent of acquisition cost annually for maintenance reserves on prior generation hardware.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

42U rack holds 14 units producing 12.04 PH/s aggregate at approximately 156 kW total power. 100 kW industrial electrical panel: approximately 8 to 9 units producing 6.88 to 7.74 PH/s aggregate. Compare alternatives at the same power budget. 100 kW of S23 Hyd 3U: 9 units producing 10.44 PH/s (35 percent more aggregate at newer generation efficiency). 100 kW of S21 XP Hydro 473TH standalone: 17 units producing 8.04 PH/s (4 percent more aggregate at universal voltage compatibility). The S21e XP Hyd 3U positions between these options on aggregate hashrate per kilowatt.

Bitmain 365 day factory warranty on the complete machine covering manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. Document coolant testing schedule and maintenance records to protect warranty coverage. MillionMiner routes warranty claims through direct Bitmain channels. As 2025 era hardware shipping from distributor inventory, verify current warranty start date with purchase batch.

Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power, LP34 industrial connectors, and hydro cooling infrastructure capable of supporting S21e XP Hyd 3U deployments. Hosted deployment eliminates facility infrastructure CapEx and leverages negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At $0.04 per kWh hosting rates, OneMiners documents approximately 12 month ROI per unit. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record. AntPool is the native Bitmain ecosystem pool. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives. For fleet deployments above 10 PH/s (equivalent to 12+ units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

CapEx beyond miner acquisition: three phase electrical service with LP34 connectors ($10,000 to $30,000 per facility), hydro cooling infrastructure ($10,000 to $40,000 per rack), industrial rack hardware ($2,000 to $5,000 per rack). Annual OpEx per unit at 11,180W continuous: electricity at $7,835 at $0.08 per kWh, $6,855 at $0.07 per kWh, $3,917 at $0.04 per kWh industrial hosting rates. Water glycol coolant maintenance and spare parts reserves. 3 year TCO per unit at $0.07 per kWh self hosted: approximately $11,649 hardware plus $20,565 electricity plus $2,000 maintenance equals $34,214 total. 3 year gross revenue at $0.07 per kWh profitability: approximately $13,200 to $17,600 depending on BTC price scenarios.

Run the math with supplier specific pricing. Illustrative scenario: if S23 Hyd 3U costs $30,000 and S21e XP Hyd 3U costs $12,000 per unit, the $18,000 price differential on the newer hardware must be recovered through efficiency savings. At 1,160 TH/s versus 860 TH/s (300 TH/s more on newer hardware) and 9.5 J/TH versus 13 J/TH efficiency gap, per year electricity savings on the newer hardware run approximately $2,600 at $0.07 per kWh. The $18,000 price differential would take 7 years to recover through pure efficiency, but the newer hardware also delivers higher revenue through 35 percent more hashrate. Factoring both efficiency savings and additional revenue, price differential recovers in approximately 18 to 30 months depending on BTC price scenarios. At deployment horizons beyond 2 years with current BTC price levels, S23 Hyd 3U typically wins. Below 18 months or at deeply discounted S21e XP pricing, the value play works.

Within Bitmain S23 generation (newer, higher efficiency): S23 Hyd 3U at 1.16 PH/s for flagship petahash, S23 Hydro 580TH standalone for single unit compact deployment, S23 Air 318TH for air cooled, S23 Immersion 442TH for tank deployment. Within Bitmain S21 generation (same era, universal voltage): S21 XP Hydro 473TH for single phase standalone, S21+ Hydro 395TH for universal voltage deployment without three phase, S21e XP Hyd 430TH for lower tier 3U alternative. For operators diversifying across manufacturers at the petahash hydro tier: Whatsminer M79S 1.35 PH/s represents MicroBT's equivalent high power hydro tier, Whatsminer M73S+ 540TH provides lower tier hydro rack mount. Cross algorithm fleet diversification: Antminer KS7 for Kaspa, Antminer L11 for Litecoin and Dogecoin merged mining, IceRiver AE3 for Aleo, Antminer Z15 for Zcash. For operations building modular long lifespan infrastructure: Proto Rig at 819 TH/s provides Block's modular 10+ year chassis alternative. MillionMiner's ASIC hosting service accepts S21e XP Hyd 3U units at negotiated industrial electricity rates.

Get a Quote