Out of Stock

MicroBT

MicroBT Whatsminer M78S 472TH

Model: Whatsminer M78S

New

472 TH/s immersion cooled SHA-256 Bitcoin miner at 7,000W and 14.83 J/TH efficiency, the top bin of MicroBT's 7 kW immersion tier in the M70 generation. Alternate efficiency profile runs 472 TH/s at 6,550W and 13.88 J/TH per multiple distributor specifications. Sits between the 14 kW hydro M79 series and the 5.2 kW immersion M76 series, giving operators a middle tier option for immersion facility scaling. 14 M78S units fit per 100 kW electrical panel producing 6,608 TH/s total versus only 7 M79S units producing 6,510 TH/s, delivering similar aggregate hashrate with smaller per unit breakers and thermal loads. 267 x 147 x 401 mm at 22 kg. 380 to 480V three phase industrial power. Currently out of stock. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

472 TH/s 7000W SHA-256 14.83 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Hashrate

472 TH/s

Power

7000 W

Efficiency

14.83 J/TH

Noise

75 dB

Estimated Mining Returns

Based on current BTC price & network difficulty. Indicative only.

Period Daily Weekly Monthly
Income
$18.31 $128.17 $549.30
Electricity
-$8.40 -$58.80 -$252.00
Profit
$9.91 $69.37 $297.30

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 15, 2026. Estimates at $0.08/kWh.

Full Specifications

Hashrate 472 TH/s
Power Consumption 7000 W
Efficiency 14.83 J/TH
Algorithm SHA-256
Model Whatsminer M78S
Release Year Dec 2025
Noise Level 75 dB
Dimensions 267 x 147 x 401mm
Weight 22 kg
Voltage AC 380-480V
Interfaces Ethernet
Operating Temp 5 - 45 °C
Humidity 5 - 95 %
Cooling Type Immersion

What's in the Box

Whatsminer M78S
Power supply unit (PSU)
Power cables
Quick start guide

Contents may vary by batch. Exact items listed in order confirmation.

Quick Setup

1

Connect PSU to miner and plug into the outlet

2

Connect ethernet cable to your router or switch

3

Find miner IP via router admin or IP scanner tool

4

Open web interface, enter pool URL and wallet — start mining

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
star star star star star

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso made-in-germany trustpilot
google-review

Get a Quote for the MicroBT Whatsminer M78S 472TH

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Product Details

MicroBT Whatsminer M78S 472 TH/s Immersion Cooled Bitcoin Miner: Facility Scaling Economics, Specifications, and Deployment Guide

The Whatsminer M78S is the top bin in MicroBT's 7 kW immersion tier of
the M70 generation, built for operators scaling into dielectric fluid immersion cooling without
committing to the aggressive infrastructure demands of 14 kW hardware. 472 TH/s SHA-256
hashrate at 7,000W and 14.83 J/TH efficiency in the rated operating mode. Multiple distributor
specifications including Mining Now and X ON Mining document an alternate operating profile at
6,550W and 13.88 J/TH, roughly 7 percent better efficiency trading slightly less headroom for
lower sustained draw.
Facility scaling economics differentiate the M78S from higher power alternatives. A 100 kW
electrical panel accommodates 14 M78S units producing 6,608 TH/s aggregate hashrate versus
only 7 M79S units producing 6,510 TH/s in the same electrical capacity. Similar total output, but
the M78S fleet uses smaller individual breakers per unit and creates lower thermal load per tank
slot. For facilities building their first immersion deployment or scaling gradually, the smaller per
unit power draw simplifies electrical provisioning, reduces initial fluid volume requirements, and
relaxes heat rejection sizing compared to 14 kW alternatives.
MicroBT's M70 generation spans multiple cooling approaches and power tiers. Air cooled
models (M70, M70S) target small to mid size operations with standard ventilation. Hydro cooled
models (M73 series, M76 series hydro variants, M79, M79S) target industrial farms with closed
loop liquid cooling. Immersion cooled models (M76 at 5.2 kW, M78 at 7 kW and 440 TH/s, M78S
at 7 kW and 472 TH/s top bin) target facilities running dielectric fluid tanks. The M78S shares
tank compatibility with the M78 and M76 series in properly sized tanks, allowing mixed fleet
deployment through the same dielectric fluid infrastructure.
Power infrastructure requires 380 to 480V three phase commercial service. At 415V three
phase the M78S draws approximately 17 amps per phase, comfortably within standard 20 amp
commercial breakers. At 480V: approximately 15 amps per phase. Compare this to the M79S at
48 amps per phase at 415V, and the electrical provisioning advantage becomes clear for
facilities with existing distribution infrastructure sized for mid power tier deployment.
Immersion cooling infrastructure needs differ from hydro loops. Required components: dielectric
fluid tanks sized for the miner count plus thermal margin, filtration and particulate management
systems, external heat rejection through coil or plate heat exchangers, fluid quality monitoring
(viscosity, dielectric strength, particulate content), and sealed enclosures for mixed coolant
vapor management. Dielectric fluid volume scales roughly 50 to 80 liters per M78S unit
depending on tank geometry and safety margin.
Bitcoin mining economics at the M78S power class vary dramatically with electricity rate. At
MillionMiner's $0.08 per kWh onsite calculator: $15.45 daily revenue, $13.44 electricity, $2.01
net profit per day. At $0.07 per kWh industrial rates: approximately $11.76 daily electricity
against similar revenue, netting $3 to $4 daily. At $0.04 per kWh negotiated industrial rates:
$6.72 daily electricity, netting $8 to $9 daily profit per unit. Profitability at residential electricity
above $0.10 per kWh is negative at current network difficulty. Industrial facility deployment with
negotiated power rates is essentially mandatory.
267 x 147 x 401 mm at 22 kg. Ethernet 10/100M management through standard Whatsminer
firmware. Full compatibility with Foreman, Awesome Miner, Hive OS, and other fleet
management platforms. 5 to 45 degrees Celsius operating range at 5 to 95 percent humidity.
PSU ships included. 360 day MicroBT manufacturer warranty on complete machine. Currently
out of stock at MillionMiner. Ships with free DDP delivery worldwide when available.

MicroBT Whatsminer M78S 472 TH/s: Top Bin of the 7 kW Immersion Tier in the

The M78S is MicroBT's top bin in the 7 kW immersion tier of the M70
generation, sitting between the high power 14 kW hydro M79 series and the lighter 5.2 kW
immersion M76 series. 472 TH/s at 7,000W in rated mode delivers 14.83 J/TH efficiency, with
an alternate 6,550W / 13.88 J/TH profile documented by Mining Now, X ON Mining, and
CryptoMinerBros.
Facility scaling math favors the M78S for operators building their first immersion deployment. A
100 kW electrical panel supports 14 M78S units producing 6,608 TH/s aggregate hashrate
versus only 7 M79S units producing 6,510 TH/s. Similar total output, smaller per unit breakers,
lower thermal load per tank slot, and simpler electrical provisioning. The tradeoff is more units
requiring more physical tank slots and management overhead.
Shares immersion tank compatibility with the M78 (440 TH/s) and M76 series (5.2 kW) in
properly sized tanks. All use dielectric fluid cooling on 380 to 480V three phase industrial power.
Infrastructure built for M78S units later accommodates 14 kW M79 series hardware as the
operation scales. 267 x 147 x 401 mm at 22 kg. Currently out of stock at MillionMiner.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Whatsminer M78S 472 TH/s Immersion Bitcoin Miner

The practical middle tier for operators scaling into immersion cooling
without committing to 14 kW M79 series infrastructure. 472 TH/s at 7,000W per unit in dielectric
fluid immersion, with an alternate efficiency profile at 6,550W and 13.88 J/TH documented
across multiple distributor sources. Facility math favors the M78S for gradual scaling: 14 units
per 100 kW electrical panel produces 6,608 TH/s aggregate versus 7 M79S units at 6,510 TH/s
in the same capacity. Smaller per unit breakers, lower thermal load per tank slot, simpler
electrical provisioning, and forward compatibility with 14 kW hardware in future expansion
phases. Shares tank compatibility with M78 (440 TH/s) and M76 series (5.2 kW) for mixed fleet
deployment. 380 to 480V three phase industrial power. Currently out of stock. Ships with 360
day warranty and free DDP from MillionMiner.

472 TH/s at 7 kW in the Immersion Middle Tier

Top bin of MicroBT's 7 kW immersion tier. Half the power of M79 series units. Fits twice as many units per electrical panel.

Dual Profile: 14.83 or 13.88 J/TH

Rated mode at 7,000W and 14.83 J/TH. Alternate efficiency profile documented at 6,550W and 13.88 J/TH across major distributors.

Forward Compatible Immersion Infrastructure

Shares tank compatibility with M78 and M76 series. Infrastructure built for M78S later accommodates 14 kW M79 hardware as the operation scales.

FAQ

Frequently Asked Questions

The M78S produces 472 TH/s of SHA-256 hashrate at 7,000W wall draw and 14.83 J/TH efficiency in the rated operating mode. Multiple distributor specifications document an alternate 6,550W / 13.88 J/TH profile running the same 472 TH/s output at meaningfully better efficiency. MicroBT rates the unit at plus or minus 3 percent hashrate tolerance. Real world output typically falls between 458 and 486 TH/s depending on batch, immersion fluid temperature, and selected operating profile.

The M78S is top bin in the 7 kW immersion tier of the M70 generation. Compared against the M78 standard variant at 440 TH/s and 7 kW: the M78S delivers 7 percent more hashrate at identical power draw. Compared against the M76 immersion at 5.2 kW: the M78S offers 35 percent more power per unit for correspondingly higher hashrate output. Compared against the 14 kW M79S hydro flagship: the M78S runs half the power per unit, fitting twice as many units per electrical panel. The M78S is the right choice for facilities scaling immersion incrementally rather than committing to 14 kW hardware immediately.

A 100 kW electrical panel supports 14 M78S units producing 6,608 TH/s aggregate hashrate. The same 100 kW panel supports only 7 M79S units producing 6,510 TH/s. Similar total output but the M78S fleet uses smaller individual breakers (20 amp versus 60 amp at 415V) and creates lower thermal load per tank slot (7 kW versus 20 kW per unit). Smaller per unit power draw means less aggressive cooling per tank slot, smaller initial fluid volume investment, simpler electrical provisioning, and easier incremental scaling. For facilities building their first immersion deployment, the M78S is often the correct starting point before committing to higher power tier hardware.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 17 amps per phase, fitting within standard 20 amp commercial breakers. At 480V three phase: approximately 15 amps per phase. Standard residential and small commercial electrical systems cannot handle the 7,000W continuous load. European, Middle Eastern, and industrial Asian facilities running three phase power have direct deployment paths. North American operators need commercial 480V three phase service or step down transformers. PSU ships included but power cord must match your three phase outlet.

Dielectric fluid immersion tanks sized for the miner count plus thermal margin. Required components: immersion tanks with appropriate fluid capacity (typically 50 to 80 liters per M78S unit depending on tank geometry), external heat exchangers (coil or plate type) sized for total facility thermal load, fluid circulation pumps, filtration and particulate management, fluid quality monitoring equipment, and sealed enclosures for vapor management. Compatible dielectric fluids include single phase oils (mineral oil, synthetic esters) and engineered two phase fluids. The M78S shares tank compatibility with the M78 and M76 series, allowing mixed fleet deployment in the same tanks.

At MillionMiner's $0.08 per kWh onsite calculator: $15.45 daily revenue, $13.44 electricity, $2.01 net profit per day. At $0.07 per kWh industrial rates: approximately $11.76 daily electricity, netting $3 to $4 daily. At $0.04 per kWh negotiated industrial rates: $6.72 daily electricity, netting $8 to $9 daily profit per unit. Residential electricity above $0.10 per kWh makes the M78S unprofitable at current difficulty. This is industrial hardware strictly for operators with negotiated industrial power rates. Mining Now March 2026 data confirms similar economics at the alternate efficiency profile.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target and largest SHA-256 network. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), and DigiByte (DGB SHA-256 chain). Mining Now confirms BTC, BCH, and Fractal Bitcoin as mineable targets for the M78S specifically. Merged mining BTC alongside BCH and BSV through supporting pools like ViaBTC and F2Pool adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

On the network and management side, yes without configuration changes. Both use standard Stratum protocol over Ethernet and identical Whatsminer firmware. The infrastructure constraint is cooling type: M78S units are immersion cooled (dielectric fluid tanks) while M79 series units are hydro cooled (closed liquid loops). These are different cooling approaches requiring separate infrastructure. Facilities running both need dedicated zones for immersion versus hydro deployment. For fleets standardizing on immersion, stay within the M76 / M78 / M78S range. For fleets standardizing on hydro, use the M73 / M76 hydro / M79 / M79S range.

Multiple distributors including Mining Now, X ON Mining, and CryptoMinerBros document an alternate M78S operating profile at 6,550W and 13.88 J/TH efficiency at the same 472 TH/s output. This represents roughly 7 percent better efficiency at 6 percent lower power draw. Use this profile when electricity costs make the 7 kW rated mode marginal, when facility thermal capacity is constrained, or when operating conditions support the tighter power envelope. Whether your specific M78S unit supports the alternate profile depends on batch and firmware version. Verify stable operation before deploying full fleet on the efficiency mode.

No. The M78S requires 380 to 480V three phase industrial power unavailable in residential settings, immersion tank infrastructure with dielectric fluid management, and professional installation for both electrical service and fluid systems. Home mining hardware caps at around 3,500W per unit running on standard 240V 20A circuits. For operators wanting high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling. The M78S is strictly industrial hardware for professional mining facilities.

Industrial deployment with three phase power and immersion infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission immersion cooling infrastructure including tanks, heat exchangers, pumps, filtration, and fluid. Step three: submerge M78S units in immersion tank slots with proper fluid contact and drain pathways. Step four: connect PSU power and Ethernet management. Step five: power on, allow fluid circulation to stabilize, find each miner IP through DHCP, configure pool URL and Bitcoin wallet through the Whatsminer web interface, verify hashrate reaches 458+ TH/s within 15 to 20 minutes.

Immersion maintenance differs from hydro or air cooled hardware. Monthly fluid quality testing (viscosity, dielectric strength, particulate content). Quarterly fluid filter inspection and replacement. Every 18 to 36 months full fluid replacement depending on fluid type and filtration quality. Heat exchanger cleaning every 6 to 12 months. Hashboard failure rates on immersion hardware are lower than air cooled because chips run at consistent temperatures without thermal cycling, but fluid management adds operational overhead. Budget 3 to 5 percent of acquisition cost annually for fluid replacement, filtration media, and maintenance parts.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share with competitive FPPS payouts. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets despite the manufacturer difference. ViaBTC offers accumulation mode payouts reducing daily variance. For fleet deployments above 4.7 PH/s (equivalent to 10+ M78S units), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates.

Yes. MillionMiner operates managed hosting facilities with immersion cooling infrastructure capable of supporting M78S deployments. Hosted deployment eliminates the substantial capital cost of building your own three phase electrical service, immersion tanks, and fluid management systems, which typically runs $30,000 to $150,000+ for meaningful fleet capacity. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

MicroBT's 360 day factory warranty on the complete machine covers manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from fluid quality neglect, contamination from improper immersion handling, physical damage during tank maintenance, power surge damage from inadequate electrical protection, and operation outside the 5 to 45 degree Celsius range. Document fluid quality testing schedule and maintenance logs to protect warranty coverage. MillionMiner routes claims through direct MicroBT channels for faster resolution than secondary market purchases.

Bitmain does not currently ship a direct immersion equivalent to the M78S in its Antminer S23 family. The closest Bitmain alternatives are the Antminer S21+ Immersion variants at around 325 TH/s and 5,800W, which run lower hashrate and power per unit. For operators comparing the immersion category, the M78S leads on hashrate per unit at 7 kW. The Antminer S23 Hyd 3U at 1.16 PH/s and 11 kW hydro is a different cooling architecture entirely. MicroBT currently has the stronger immersion product portfolio for facilities committed to dielectric fluid infrastructure.

Currently out of stock. Use the Notify Me button on the MillionMiner product page for email alerts when new inventory arrives. Use the Get a Quote button to contact MillionMiner sales directly for estimated restock timing and priority reservation on incoming batches. Industrial immersion hardware moves quickly when batches arrive because the deployment market is concentrated among facility operators with standing orders.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M78S units automatically through network scanning. Additional monitoring metrics for immersion operation (fluid temperature, pump flow rate) appear in immersion specific dashboards when supported. Mixed brand and cooling type fleets handle through unified dashboards with immersion specific alerts for fluid temperature excursions.

CapEx additions beyond miner acquisition: three phase electrical service installation ($3,000 to $15,000 per facility), immersion tank infrastructure ($8,000 to $25,000 per rack depending on capacity and fluid type), fluid fill volumes ($2,000 to $6,000 per tank depending on fluid chemistry), heat exchanger and pump systems ($5,000 to $20,000 per rack), racks and cabling. Annual OpEx per unit: electricity at 7 kW ($4,912 at $0.08 per kWh, $2,453 at $0.04 per kWh), fluid maintenance ($200 to $800 per unit annually), spare parts. MillionMiner hosting eliminates CapEx and simplifies monthly OpEx tracking.

A MicroBT immersziós kínálatán belül: a Whatsminer M78 440 TH/s-sel biztosítja az M78S szabványos változatát, és az M76S / M76 sorozat 5,2 kW-os fogyasztással lefedi az alacsonyabb teljesítményű immersziós telepítéseket. A MicroBT családon belül: a hidro változatú M79 és M79S alternatív folyékony hűtési megoldást kínál, míg a levegőhűtésű M70 és M70S azoknak a létesítményeknek a zónáit kezelik, amelyek nem rendelkeznek immersziós infrastruktúrával. Márkák közötti lehetőségek: az Antminer S21+ 235 TH/s-sel és az Antminer S21 XP 270 TH/s-sel lefedik az levegős hűtéssel működő kevert hűtési létesítmények zónáit. Az olyan operátorok számára, akik diverzifikált algoritmus flottákat üzemeltetnek, az Antminer KS7 45 TH/s-sel lefedi a Kaspa bányászatát. A MillionMiner ASIC hosting szolgáltatása elfogadja az M78S egységeket egyeztetett ipari elektromos áramdíjak mellett.

Get a Quote