Nessun prodotto trovato per ""
Bitmain
Modello: Antrack V1 (24KW)
Condizione: nuovo
Complete plug and play hydro cooling rack for up to four Bitmain Antminer Hydro miners (S19 Hyd, S21 Hyd, S23 Hyd series). 24 kW maximum load with integrated water pump, plate heat exchanger, eight fans, PDU, hoses, and all cabling built in. No external radiator required. Waste heat recovery ready for underfloor heating, aquaculture, greenhouse, or industrial process heating applications. 380 to 415V three phase at 80 amps. 600 x 2000 x 1000 mm at 300 kg. Ships from MillionMiner with 1 year replacement parts warranty and free DDP delivery worldwide.
Temporarily Unavailable
This product is temporarily unavailable.
Notify Me
Be the first to know when this miner becomes available.
We'll notify you when it's available!
Genuino
Hardware testato
In tutto il mondo
Spedizione globale
Supporto
Esperti di estrazione mineraria
I nostri specialisti minerari possono aiutarti a trovare il miner perfetto per la tua configurazione e il tuo budget.
Pump, heat exchanger, fans, PDU, hoses, and cabling all built in. No external radiator. No DIY assembly.
Houses S19 Hyd, S21 Hyd, or S23 Hyd units. Mix generations freely. Up to 2.32 PH/s per rack.
Redirect 82,000 BTU/hr into underfloor heating, aquaculture, or greenhouses. Mining plus heating revenue.
The Antrack V1 is a complete self contained hydro cooling mining rack, not a miner itself. It ships with every component needed for hydro mining already integrated: a water circulation pump, a plate heat exchanger, eight cooling fans, a PDU for power distribution, all internal hoses, and all cabling. Four rack slots accept Bitmain Antminer Hydro miners. You supply the miners, three phase power, Ethernet, and water. The Antrack provides everything else.
The Antrack V1 supports the full Bitmain Hydro miner lineup: S19 Hyd, T19 Hyd, S19 Pro Hyd, S19 Pro+ Hyd, S21 Hyd, S21 XP Hyd, and S23 Hyd series. Four units fit simultaneously. You can mix different Hydro generations in the same rack without compatibility issues since each slot provides independent power and network connections. When running older S19 generation models, keep ambient temperature below 35 degrees. S21 and S23 units tolerate the full 45 degree range.
No. The Antrack V1 has an integrated heat exchanger and eight cooling fans built in. This is the defining advantage over building a DIY hydro setup from separate components. The internal cooling system manages the full thermal loop. You connect power, slide in your miners, and the rack handles coolant circulation and heat dissipation without any external cooling equipment.
he integrated plate heat exchanger outputs waste heat that can be redirected to practical applications instead of dumping it into the environment. At 24 kW maximum load, the Antrack produces roughly 82,000 BTU per hour of recoverable thermal energy. Documented deployments include underfloor heating for buildings up to 450 square meters, a Japanese aquaculture farm maintaining seawater temperature for abalone production (replacing $104 per day in electric heating), and greenhouse heating during cold months. The waste heat turns mining from a single revenue operation into a dual revenue system.
380 to 415V AC three phase power at up to 80 amps input current. This is industrial electrical infrastructure, not residential power. The Antrack draws power proportional to the miners installed. Four S21 XP Hydro units at 5,676W each total approximately 22.7 kW. Four S23 Hyd units at roughly 6,000W each approach the full 24 kW capacity. Verify your facility's three phase circuit capacity before ordering.
600 mm wide, 2,000 mm tall, and 1,000 mm deep. Net weight is 300 kg before miners are installed. Each Hydro miner adds 13 to 22 kg depending on model. Total loaded weight with four miners runs approximately 355 to 390 kg. The unit needs a solid, level floor and at least 1 meter of clearance in front and behind for airflow circulation. Standard freight delivery and forklift placement for positioning.
Depends on which Hydro miners you install. Four S21 XP Hydro units (473 TH/s each) produce 1,892 TH/s, nearly 1.9 PH/s. Four S23 Hyd units (580 TH/s each) produce 2,320 TH/s, roughly 2.32 PH/s. Four S21 Hyd units (335 TH/s each) produce 1,340 TH/s. The Antrack V1 itself does not add hashrate. It provides the cooling, power distribution, and rack infrastructure for the miners that do.
Water conductivity must remain below 100 microseconds per centimeter. The system ships with conductivity below 20. Monitor conductivity periodically and replace the fluid when it approaches the 100 threshold. Standard deionized or distilled water works for the initial fill. Water flow rate across the four slots runs 32 to 40 liters per minute during normal operation. No dielectric fluid is needed; this is a water based cooling system.
Bitmain provides 1 year replacement parts warranty covering manufacturing defects and component failures under normal operation. The warranty covers the built in pump, heat exchanger, fans, PDU, and internal cabling. It does not cover damage from improper electrical installation, water quality violations, or physical mishandling during transport. MillionMiner routes warranty claims through their support team for faster resolution.
MillionMiner ships the Antrack V1 brand new with free DDP delivery worldwide, handling all customs clearance, import duties, and taxes. At 300 kg and industrial dimensions, the Antrack ships via freight carrier rather than standard parcel service. Contact MillionMiner sales for current pricing, bulk rack configurations, and integration planning for hosting site deployments. Pricing for industrial infrastructure equipment fluctuates with demand and Bitmain batch availability.