Hydro-cooled miners use closed-loop water cooling instead of fans to remove heat from ASIC chips. The result is lower noise (around 50 dB compared to 75+ dB on air-cooled equivalents), better energy efficiency, higher rack density, and longer hardware lifespan. Hydro-cooled facilities achieve PUE of approximately 1.03, meaning only 3% energy overhead beyond the miners themselves, compared to 20%+ on air-cooled data centers. Hydro miners are designed exclusively for data center and industrial hosting operations. They require 380 to 415V three-phase power, liquid cooling infrastructure, and 8 to 10 L/min coolant flow rates. They are not suitable for home mining and should not be ordered for residential deployment. The MillionMiner catalog covers 68 hydro models including the full Bitmain S23 Hydro lineup (580 TH/s at 9.5 J/TH, 865 TH/s, and 1,160 TH/s on the S23 Hydro 3U), the S21 XP Hyd (473 TH/s at 12 J/TH), and WhatsMiner Hydro variants. The majority mine Bitcoin (SHA-256), with select Scrypt and KHeavyHash hydro options for Dogecoin/Litecoin and Kaspa operations. MillionMiner's US hosting facilities support full hydro infrastructure including plumbing, flow monitoring, and pressure management. For operators building their own setups, Lianli radiators and cooling cabinets are available in the Equipment category.
검증된 장비
Bitmain & Lian Li 공식 공급처
전체 시스템 지원
Miners, coolant, infrastructure & accessories
Crypto Accepted
BTC, ETH, USDT 등으로 결제하세요
Expert Support
냉각 시스템 전문가 대기 중
The era of air-cooled mining farms is giving way to liquid cooling infrastructure. As ASIC power densities exceed what air can efficiently dissipate — flagship Bitcoin miners now drawing 3,500W+ per unit — serious operations are moving to hydro-cooled and immersion-cooled systems that deliver dramatically lower PUE, higher hashrate density per square metre, near-silent operation, and extended hardware lifespan. We stock the full Bitmain Antminer Hydro series, Lian Li mining containers, immersion tanks, CDUs, radiators, pumps, coolant, cables, and every component needed to build a complete liquid cooling infrastructure from the ground up.
PUE 향상
~1.03 PUE
일반 공랭 설비의 경우 1.4–1.6
소음 감소
~45 dB
공기 냉각 ASIC의 경우 75~85 dB와 비교하십시오.
밀도 향상
3–5×
공기 냉각 랙 대비 더 많은 해시레이트 / m²
Hardware Lifespan
+30–50%
확장된 ASIC 수명 대 공랭
모든 채굴 작업은 세 가지 기본 냉각 방식 중 하나를 기반으로 수행됩니다. 비용, 밀도, 효율성 및 작업 복잡성의 차이는 매우 크며 — 규모에 맞지 않는 잘못된 방식을 선택하는 것은 비용이 많이 드는 실수입니다.
The traditional approach: ASICs draw ambient air through the chassis with high-RPM fans, exhausting hot air out the back. Every ASIC you have ever seen ships with this system built in. No external infrastructure required beyond a ventilated space and power.
Zero additional infrastructure cost
간단한 설치, 어떤 장소에서도
Standard warranties and support
75–85 데시벨 — 매우 시끄러움
PUE 1.4–1.6 — 높은 냉각 비용
먼지 섭취는 시간이 지남에 따라 하드웨어를 손상시킵니다
Low density — large floor area required
Best for
Home miners, small farms under 50 units, first-time operators
Hydro miners are purpose-built ASICs where the heat exchanger is water-cooled rather than fan-cooled. The ASIC chip generates heat, which transfers into a closed water loop via an internal cold plate. That heated water circulates to an external radiator (CDU) which dissipates the heat — either to ambient air via a dry cooler or to a cooling tower. The fans are eliminated entirely or dramatically reduced.
40–50 dB — 거의 조용한 작동
PUE ~1.05~1.10 — 매우 효율적
Standard rack-mountable form factor
화학 냉각제 없음 — 일반 물 사용
외부 CDU / 라디에이터 인프라가 필요합니다.
호스, 피팅, 펌프는 설치 비용을 증가시킵니다
Dedicated hydro ASIC hardware required
Best for
Mid-to-large farms, noise-sensitive locations, high-density deployments
침수 냉각은 전체 ASIC 하드웨어 — 보드, 칩, 모두 — 를 밀폐된 탱크 내부의 유전체(엔지니어드 오일) 욕조에 직접 잠수시킵니다. 이 유체는 모든 부품 표면에서 직접 열을 흡수하고 동시에 열 교환기로 순환합니다. 공기는 움직이지 않으며, 팬이 작동하지 않고, 먼지가 들어오지 않습니다. 열역학은 어떤 공기 기반 방법보다 근본적으로 우수합니다.
PUE ~1.02–1.03 — 이론상 최대치에 가까움
표준 공랭 ASIC(팬 제거)와 호환됩니다
1㎡당 최대 가능한 해시레이트 밀도
Zero dust, corrosion, or humidity degradation
가장 높은 선행 인프라 투자
Dielectric fluid cost & ongoing management
Maintenance access requires fluid handling
Best for
대규모 산업 운영, 공간이 제한된 부지, 최대 효율성 요구
수냉 ASIC는 특수 제작된 기계로, 기존의 공냉식이 아니며, 개조된 공랭기를 사용하지 않습니다. 비트메인의 Antminer Hydro 시리즈(S19 Hydro, S21 Hydro)는 축 팬이 없으며, 대신 내부에 수냉 블록이 해시 보드 부품에 직접 접착되어 있습니다. 냉각수는 일반적으로 맑은 물이나 부식 방지 성분이 첨가된 물-글리콜 혼합물로, 내부 블록을 통해 흐르면서 칩의 열을 흡수하고, 후면 패널의 빠른 연결 부착구를 통해 외부 냉각 회로로 배출됩니다.
외부 냉각 루프는 펌프(회로를 통해 냉각수를 순환시키는), 분배 매니폴드(흐름을 여러 기계로 분할하는), 퀵 디스커넥트 커플링이 있는 유연한 호스(도구 없이 기계를 교체할 수 있는), 그리고 환경에 열을 방출하는 냉각수 분배 장치(CDU) 또는 라디에이터로 구성됩니다. 추운 기후에서는 드라이 쿨러를 통한 자유 냉각이 전체 냉각 시스템의 전력 소비를 거의 제로에 가깝게 줄일 수 있으며, 겨울철에는 PUE가 1.0에 가까워질 수 있습니다.
The critical operational advantage of hydro over immersion is serviceability: a hydro miner sits in a standard rack, connects to quick-disconnect hose fittings, and can be swapped in under two minutes without fluid handling equipment. Maintenance is nearly identical to air-cooled hardware — you just unplug hoses instead of power cables. For operations that cycle hardware frequently or need rapid fault resolution, hydro cooling offers the best balance of efficiency and operational simplicity.
냉수 공급
CDU or dry cooler delivers cooled water (typically 30–40°C) to the distribution manifold at the head of the rack.
다양체 분포
A supply manifold splits flow across all machines in the rack. Each machine connects via quick-disconnect hose fittings — no tools required for connection or removal.
Internal Cold Plate
Inside each hydro ASIC, water flows through a cold plate bonded directly to the hash board chips. Heat transfers from chip to water. Water exits 10–20°C warmer than it entered.
반환 만인지 컬렉션
모든 기계에서 나온 온수는 회수 배관에 모여 하나의 온난한 흐름으로 CDU로 다시 흐릅니다.
Heat Rejection (CDU / Dry Cooler)
The CDU transfers heat from the closed mining loop to an external rejection loop — either a dry cooler (fan-based outdoor unit) or a cooling tower for large installations. In cold climates, a dry cooler can run with near-zero fan power.
침수 탱크
A sealed stainless steel or fibreglass tank — typically 1,000–3,000L capacity — housing the hardware. Each tank holds 12–48 standard ASICs (fans removed) stacked horizontally in purpose-built frames. The entire interior is filled with dielectric fluid.
Dielectric Fluid
Engineered mineral oil or synthetic dielectric fluid (e.g. Engineered Fluids BitCool, 3M Novec). Electrically non-conductive so safe in contact with live electronics. Thermal conductivity ~4× better than air. Non-flammable. Reusable indefinitely with filtration. Top-up required periodically due to evaporation.
Heat Exchanger Coil
A coil of heat-exchange tubing sits submerged in the warm dielectric bath. Clean water circulates through this coil, absorbing heat from the fluid and carrying it out of the tank. The fluid and water never mix — they exchange heat through the coil wall only.
CDU / External Cooling Loop
탱크 코일의 온수는 최종 대기 방출을 위해 외부 냉각수 분배 장치, 건식 냉각기 또는 냉각 타워로 흐릅니다. 이것은 수냉 냉각 외부 루프와 구조적으로 동일합니다.
여과 및 모니터링
Continuous filtration removes particulate contamination from the dielectric fluid. Sensors monitor fluid temperature, level, and flow rate. Management software tracks per-tank thermal load and flags anomalies.
침수 냉각은 냉각 매체와 열원 사이의 열적 경계를 제거하기 때문에 다른 모든 냉각 방법과 근본적으로 다릅니다. 공기 냉각에서는 열이 칩에서 히트스프레더, 히트싱크 방열판, 그리고 움직이는 공기로 전달되어야 하며 — 여러 인터페이스가 각각 열 저항을 더합니다. 침수 냉각에서는 유전 유체가 모든 부품의 모든 표면과 직접 접촉합니다. 그 결과, 동일한 작업 부하를 수행하는 공기 냉각 구성보다 칩 접합 온도가 30–50°C 낮아집니다.
Lower chip temperatures have compounding operational benefits. ASIC failure rates are directly correlated with thermal cycling and sustained high temperatures — immersion-cooled hardware routinely achieves 5–7 year operational lifespans versus 2–3 years for air-cooled machines in hard-running industrial environments. Many operators run immersion ASICs at conservative clock frequencies to maximise longevity, or overclock aggressively knowing the thermal headroom exists. Both strategies are viable in ways they simply are not with air cooling.
또 다른 주요 이점은 하드웨어 유연성입니다: 대부분의 단상 침수 탱크는 표준 공랭 ASIC를 팬이 제거된 상태로 수용할 수 있습니다(팬 헤더가 저항기로 연결됨). 이는 전용 침수 하드웨어를 구입할 필요 없이 기존의 Antminer S21, WhatsMiner M60 또는 KS5를 저렴한 팬 개조와 함께 바로 탱크에 넣을 수 있음을 의미합니다. 이는 전용 수냉형 머신이 필요한 수력 냉각 방식에 비해 중요한 자본 효율성의 이점입니다.
두 가지 모두 공랭에 비해 현저히 우수합니다. 이들 중 선택은 규모, 운영 방식, 자본 배분에 달려 있습니다.
일반적인 규칙: 하드웨어를 자주 교체하고 운영의 복잡성을 최소화하려면 수압이 승리합니다. 만약 고정된 대규모 설치를 구축하며 가장 낮은 PUE와 가장 긴 하드웨어 수명을 원한다면 침수 냉각이 승리합니다. 많은 전문 운영팀은 최신 세대 하드웨어(자주 교체하는 경우가 많은)를 위해 수압 냉각을 사용하고, 오래된 세대 기계(오랜 감가상각 주기를 거치는 기계)는 침수 냉각을 사용합니다.
전체 채굴기부터 모든 파이프, 펌프, 패널까지 완벽한 수냉 또는 몰입 냉각 시스템을 구축하는 데 필요한 모든 것.
목적에 맞게 제작된 수냉 ASIC. 팬 대신 내부 냉판으로 교체됨. 도구 없이 설치할 수 있는 빠른 연결 후면 피팅. 현재 라인업에는 S19 Hydro(158 TH/s), S21 Hydro(335 TH/s), Kaspa용 KS5 Hydro가 포함되어 있습니다. Bitmain 자체 CDU 시스템 또는 타사 냉각 인프라와 직접 통합되도록 설계됨.
턴키 ISO 표준 배송 컨테이너로 수력 또는 침수 채굴에 미리 구성되어 있습니다. 리안리의 채굴 컨테이너는 냉각 인프라, 전력 분배, 네트워크 스위칭, 물리적 보안을 하나의 배포 가능한 유닛으로 통합합니다. 비트맨의 컨테이너 솔루션은 그들의 Hydro ASIC 시리즈를 중심으로 설계되었습니다. 20피트 및 40피트 구성으로 제공되며 — 용량은 컨테이너당 100~400대입니다.
단상 유전체 침지 탱크는 다양한 용량(12단위, 24단위, 48단위 구성)으로 제공됩니다. 스테인리스 스틸 구조, 통합형 열 교환기 코일, 유체 입출구 연결부, 상부 로딩 액세스 커버를 갖추고 있습니다. 24시간 연중무휴 연속 작동으로 설계되었습니다. 표준 공랭식 ASIC(팬 개조)뿐만 아니라 특별 제작된 침지 하드웨어와 호환됩니다.
Coolant Distribution Units (CDUs) and dry-cooler radiators for the external heat rejection loop. Bitmain's own CDU range is designed to integrate directly with the Antminer Hydro series, available in capacities from 50kW to 400kW per unit. Third-party dry coolers and plate heat exchangers available for custom system design and for immersion cooling external loops.
수력 및 침수 1차 루프용 순환 펌프. 소형 싱글랙 펌프(20–50 L/분)부터 대단위 시설 규모의 유닛까지 크기 선택 가능. 6방향, 12방향, 24방향 구성을 갖춘 스테인리스 또는 황동 분배 매니폴드로 냉각수 흐름을 여러 기기 또는 랙에 분산. 정밀한 기기별 흐름 최적화를 위한 밸런싱 밸브와 유량계도 구비되어 있습니다.
Quick-disconnect push-fit couplings compatible with Bitmain Hydro series rear fittings (G1/4", 3/8", 1/2" options). Reinforced EPDM coolant hoses in various lengths. Dielectric fluid (single-phase engineered mineral oil and synthetic options). Corrosion inhibitor concentrate for water-glycol systems. Filtration cartridges, fluid analysis kits, temperature sensors, flow meters, and monitoring hardware.
Liquid cooling systems reward proper planning and punish improvisation. These are the mistakes that cost operators the most.
미래 확장을 위한 냉각 루프 축소
수력 시스템 설계에서 가장 비싼 실수. 운영자들은 종종 펌프, 매니폴드, 그리고 CDU 용량을 현재 기계 수에 맞춰 정확히 산정한 후 — 유닛을 추가하고 시스템이 열적으로 포화 상태에 도달하는 것을 발견합니다. 처음부터 계획 용량의 150%에 맞게 1차 루프를 설계하십시오. 펌프 업그레이드와 추가 CDU 용량은 가능하지만 복잡하고 방해가 됩니다. 매니폴드 포트와 배관 직경은 루프를 재구축하지 않고는 거의 확장할 수 없습니다.
수처리 없이 수돗물 사용하기 in 수력 시스템
처리되지 않은 수돗물에는 용해된 미네랄, 염소 및 생물학적 물질이 포함되어 있어 냉각판에 스케일이 쌓이고, 피팅에서 부식이 발생하며, 루프 내에서 미생물이 성장하게 됩니다. 항상 혼합 금속 냉각 시스템(알루미늄 냉각판, 구리 피팅, 스테인리스 매니폴드)을 위해 특별히 제조된 부식 억제제 혼합물이 포함된 탈이온수(Deionised water)를 사용하십시오. 루프 화학 성분은 분기별로 테스트하십시오. 스케일 축적으로 인해 막힌 냉각판은 고장난 팬만큼이나 ASIC을 죽입니다.
Removing Fans From ASICs Before Confirming Immersion Compatibility
모든 ASIC이 안전하게 침수될 수 있는 것은 아닙니다. 일부 기계는 열전도 페이스트의 조성이나 커패시터 유형이 절연액 내에서 성능 저하를 일으키기도 합니다. 일부 펌웨어는 팬 고장으로 인한 셧다운이 발생하며, 이를 비활성화할 수 없습니다. 구매 전에 특정 하드웨어 모델과 펌웨어 버전의 침수 적합성을 확인하세요. Bitmain은 침수 적합성 목록을 공개하며, 참고하시기 바랍니다. 표준 S21 Pro는 침수 호환이 확인되었으며, 기타 모델은 별도의 검증이 필요합니다.
수력 시스템에서 기계별 냉각수 흐름 속도 무시하기
각 Antminer Hydro 기계에는 지정된 최소 냉각수 유량(일반적으로 1대당 4~8리터/분)이 있습니다. 기계를 과소유량하면 대량의 물 온도가 양호하게 보여도 냉각판이 국소적으로 과열될 수 있습니다. 이는 집단 온도 센서상 열적으로 건강해 보여도 수력 배치에서 흔히 발생하는 해시 보드 고장의 원인입니다. 분배관에 유량계를 설치하고 시운전 시 기계별 유량을 균형 있게 조절하세요.
몰입 탱크는 유지보수 부담이 없다고 가정할 경우
Immersion tanks are low-maintenance but not zero-maintenance. Dielectric fluid absorbs water vapour and particulate contamination over time — fluid viscosity and dielectric constant degrade. Most manufacturers recommend fluid testing every 6–12 months and full fluid replacement every 2–3 years depending on operating conditions. Neglecting this leads to reduced thermal performance, potential corrosion, and in extreme cases fluid becoming slightly conductive. Budget for ongoing fluid management from day one.
현장 수자원 확보 없이 수력 인프라 구매
Hydro cooling systems require a reliable source of make-up water to compensate for evaporation losses at the dry cooler. Large installations can lose hundreds of litres per day to evaporation in hot weather. Verify your site has adequate water supply, appropriate water quality, and permission to discharge blowdown water (if using evaporative cooling towers). This is a site planning issue that has killed hydro projects after infrastructure was already installed.
운영자가 액체 냉각으로 전환하기 전에 가장 자주 받는 질문에 대한 답변.
위의 모든 하이드로 마이너, 침지 탱크, 컨테이너, CDU 및 액세서리의 전체 제품군을 둘러보세요. 새로운 하이드로나 침지 시스템 배치를 계획 중이고 시스템 크기 조정을 위한 도움이 필요하시면 저희 팀에 문의하세요 — 완전한 설치를 위한 시스템 설계 무료 상담을 제공합니다.