Model: Whatsminer M73S+

Nowy

540 TH/s hydro cooled SHA-256 Bitcoin miner at 7,200W and 13.33 J/TH efficiency, the top bin of MicroBT's M73 rack mount hydro tier in the M70 generation. Manufacturer headline specs per Blockspace Media and Hashrate Index document the broader binning range at 540 to 600 TH/s with 12.5 J/TH leading efficiency rating, tying the M73S+ with the M76S+ for best efficiency across the entire M70 generation. Overclock mode scales to 10,000W for higher output. Closed loop water cooling in a 4U rack mount chassis for standard 19 inch server racks, avoiding the specialized dielectric fluid and custom tank infrastructure of immersion approaches. 10 M73S+ units per 42U rack produce 5.4 PH/s at 72 kW. 483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase industrial power. Ships with PSU, 360 day MicroBT warranty, and free DDP worldwide from MillionMiner.

540 TH/s 7200W SHA-256 13.33 J/TH

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Autentyczny

Przetestowane urządzenia

Na cały świat

Globalna wysyłka

Wsparcie

Eksperci ds. górnictwa

Wydajność haszowania

540 TH/s

Moc

7200 W

Wydajność

13.33 J/TH

Hałas

75 dB

Szacowane zyski z wydobycia

Oparte na bieżącej cenie BTC i trudności sieci. Tylko orientacyjnie.

Okres Codziennie Tygodniowy Miesięczny
Dochód
$54.48 $381.36 $1,634.40
Elektryczność
-$13.82 -$96.74 -$414.60
Zysk
$40.66 $284.62 $1,219.80

Using 0.080 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Aktualizowane codziennie. Ostatnia aktualizacja: May 10, 2026. Estimates at $0.08/kWh.

Pełne specyfikacje

Wydajność haszowania 540 TH/s
Zużycie energii 7200 W
Wydajność 13.33 J/TH
Algorytm SHA-256
Model Whatsminer M73S+
Rok wydania Gru 2025
Poziom hałasu 75 dB
Wymiary 483 x 663 x 86mm
Waga 29.5 kg
Napięcie AC 380-480V
Interfejsy Ethernet
Temperatura pracy 5 - 45 °C
Wilgotność 5 - 95 %
Typ chłodzenia Hydro
Format rack 4U

Co jest w pudełku

Whatsminer M73S+
Zasilacz jednostki (PSU)
Przewody zasilające
Szybki przewodnik startowy

Zawartość może się różnić w zależności od partii. Dokładne elementy wymienione są w potwierdzeniu zamówienia.

Szybka konfiguracja

1

Connect PSU to miner and plug into the outlet

2

Podłącz kabel Ethernet do routera lub switcha

3

Znajdź adres IP kopacza za pomocą panelu administracyjnego routera lub narzędzia skanującego IP

4

Otwórz interfejs sieciowy, wpisz adres puli i portfel — rozpocznij kopanie

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Szczegóły produktu

MicroBT Whatsminer M73S+ 540 TH/s Hydro Cooled 4U Rack Mount Bitcoin Miner: Efficiency Leader Specifications and Deployment Guide

The Whatsminer M73S+ is the top bin of MicroBT's M73 rack mount hydro tier and co leader on efficiency across the entire M70 generation. MillionMiner rated spec: 540 TH/s at 7,200W and 13.33 J/TH. Manufacturer headline per Blockspace Media and Hashrate Index documents the broader binning range at 540 to 600 TH/s with 12.5 J/TH leading efficiency rating, tying the M73S+ with the M76S+ immersion variant for best efficiency across the entire generation. Overclock mode scales to 10,000W for approximately 600 TH/s peak output. The cooling architecture distinguishes the M73 series from MicroBT's other hydro options. Unlike immersion variants that submerge chips in dielectric fluid, the M73S+ uses closed loop water cooling. Water flows through internal channels in a sealed 4U rack mount chassis and carries heat to an external cooling loop. Units install in standard 19 inch server racks alongside any other data center equipment. No immersion tanks. No dielectric fluid. No custom tank infrastructure. Just water lines and standard server racking. Rack density works out to 10 M73S+ units per 42U rack (factoring space for cooling manifolds and cable management) producing 5.4 PH/s at 72 kW per rack. Compare this against immersion alternatives: a 100 kW panel with M76S+ units produces 7,410 TH/s in tanks requiring specialized infrastructure, versus a 42U rack with M73S+ units producing 5,400 TH/s in standard server racks requiring only water lines and off the shelf cooling equipment. The infrastructure tradeoff favors hydro for facilities already operating water cooled data center equipment, and favors immersion for dedicated mining facilities purpose built around tanks. Water cooling infrastructure requirements: closed loop water circulation using off the shelf pumps, standard plumbing fittings, and common water glycol coolant. Dry coolers, heat exchangers, and chillers size to the facility's total thermal load. The 7.2 kW per unit thermal output (24,570 BTU per hour) scales proportionally to fleet size. No specialized dielectric fluid at $5+ per liter. No custom tank fabrication. Standard industrial cooling equipment available from any data center supplier. Power infrastructure requires 380 to 480V three phase commercial or industrial service. At 415V three phase the M73S+ draws approximately 17 amps per phase in rated mode, or 24 amps per phase in overclock mode. Fits within standard 20 amp commercial breakers in rated mode. Overclock mode requires upgraded 32 amp breakers for reliable operation. The M73 series lineup covers three bins at different hashrate and efficiency grades. M73 base: 470 TH/s at 14.5 J/TH. M73S mid: 500 TH/s at 13.5 J/TH. M73S+ top: 540 to 600 TH/s at 12.5 J/TH. All three share the 4U chassis, 7,200W rated power envelope, and water cooling architecture. Mix bins in the same rack based on acquisition cost optimization. Bitcoin mining economics: MillionMiner's $0.08 per kWh onsite calculator shows $17.64 daily revenue, $13.82 electricity, $3.81 net profit per day. At $0.04 per kWh industrial rates: $6.91 daily electricity, netting $10 to $11 daily per unit. At upper bin output of 600 TH/s in overclock mode, daily revenue improves meaningfully at the cost of higher electricity draw. Run overclock calculations carefully against your specific electricity rate because the additional 2.8 kW draw must recover through proportional hashrate gains to justify the efficiency tradeoff. 483 x 663 x 86 mm at 29.5 kg. Ethernet 10/100M management through standard Whatsminer firmware with Foreman, Awesome Miner, Hive OS compatibility. 5 to 45 degrees Celsius operating range at 5 to 95 percent humidity. PSU ships included. 360 day MicroBT manufacturer warranty. Free DDP delivery worldwide from MillionMiner.

MicroBT Whatsminer M73S+ 540 TH/s: Rack Mount Hydro at M70 Leading

M73S+ znajduje się na szczycie wydajności generacji M70 firmy MicroBT
obok immersyjnej wersji M76S+. Oba modelu charakteryzują się współczynnikiem efektywności 12,5 J/TH,
potwierdzonym przez Blockspace Media i Hashrate Index podczas premiery Bitcoin MENA 2025.
M73S+ osiąga tę efektywność dzięki chłodzeniu wodnemu zamontowanemu w szafie rack, a nie przez immersion, co
znacząco zmienia historię infrastruktury.
Specyfikacja według MillionMiner: 540 TH/s przy 7200W i 13,33 J/TH. Wiodący opis producenta na podstawie relacji z premiery:
zakres wydajności od 540 do 600 TH/s przy 12,5 J/TH z trybem overclocking do 10,000W, aby uzyskać wyższy
woutput. Operatorzy uruchamiają tryb nominalny dla stabilnej pracy 24/7 lub podkręcają go w trybie overclocking,
jeżeli dostępne są odpowiednie zasilanie i chłodzenie.
Chłodzenie wodne różni się od immersion. M73S+ nie zanurza się w płynie. Woda przepływa przez
wewnętrzne kanały w zamkniętej obudowie 4U i odprowadza ciepło do zewnętrznego obiegu chłodzenia. Jednostki
montuje się w standardowe szafy serwerowe 19 cali obok innego wyposażenia centrum danych. 10 jednostek M73S+
w szafie 42U generuje 5,4 PH/s przy 72 kW. Chłodzenie wodne korzysta z dostępnych pomp, standardowych
rur i chłodziwa na bazie glikolu wodnego. Immersja wymaga specjalistycznego płynu dielektrycznego,
co wiąże się z wyższymi kosztami i niestandardową infrastrukturą zbiornikową. Dla operatorów centrów danych
z doświadczeniem w chłodzonych cieczą serwerach obliczeniowych seria M73 integruje się z znaną infrastrukturą.
Wymiary: 483 x 663 x 86 mm, waga 29,5 kg. Zasilanie trójfazowe 380 do 480V. Dostarczany z 360-dniową
gwarancją MicroBT oraz bezpłatną dostawą DDP na cały świat.

Potrzebujesz pomocy przy wyborze?

Nasi specjaliści ds. wydobycia pomogą Ci znaleźć idealny kopalnik dopasowany do Twojego zestawu i budżetu.

Whatsminer M73S+ 540 TH/s Hydro 4U Bitcoin Miner

Top bin of MicroBT's rack mount hydro tier and efficiency co leader across
the entire M70 generation at 12.5 J/TH headline rating (tied with M76S+). MillionMiner rated
spec: 540 TH/s at 7,200W and 13.33 J/TH. Manufacturer headline: 540 to 600 TH/s binning
range with overclock mode reaching 10,000W. Closed loop water cooling in a 4U rack mount
chassis for standard 19 inch server racks. Avoids the specialized dielectric fluid and custom tank
infrastructure of immersion approaches. 10 units per 42U rack produce 5.4 PH/s at 72 kW.
Water cooling uses off the shelf pumps, standard plumbing, and common water glycol coolant.
483 x 663 x 86 mm at 29.5 kg. 380 to 480V three phase. Ships from MillionMiner with 360 day
warranty and free DDP worldwide.

540 TH/s at M70 Leading Efficiency

Nagłówek producenta 12,5 J/TH według Blockspace i Hashrate Index. Łączy M76S+ z najlepszą wydajnością w całej generacji M70.

Standard 4U Rack Mount, Water Cooled

Sealed 4U chassis for 19 inch server racks. Water lines, not immersion tanks. Integrates into existing liquid cooled data center infrastructure.

Rated 7,200W, Overclock to 10,000W

Rated mode at 540 TH/s and 7,200W. Overclock mode scales to 10,000W for approximately 600 TH/s peak hashrate at higher power draw.

Request a Bitcoin Miner Hosting Quote

4.7
gwiazda gwiazda gwiazda gwiazda gwiazda

4.7/5 Verified on Trustpilot

  • koperta 30,000+ miners hosted since 2020
  • stoper Trusted by 1,200+ customers globally
iso wyprodukowane w Niemczech trustpilot
recenzja-google

Need a Hosting Offer?

Tell us what you need and our team will send you a customized ASIC miner hosting quote

górnik

Górnik

hosting

Hosting

Najczęściej zadawane pytania

Najczęściej zadawane pytania

M73S+ generuje hashrate SHA-256 na poziomie 540 TH/s przy poborze mocy 7200 W i efektywności 13,33 J/TH w specyfikacji ocenianej przez MillionMiner. Kluczowe dane producenta według dokumentów Blockspace Media i Hashrate Index obejmują szerszy zakres binów od 540 do 600 TH/s z wiodącą efektywnością na poziomie 12,5 J/TH. Tryb podkręcania zwiększa moc do 10 000 W, osiągając ok. 600 TH/s szczytowej wydajności. MicroBT ocenia jednostkę z tolerancją hashrate na poziomie plus lub minus 3 procent. Wartość 12,5 J/TH czyni M73S+ równorzędnym z wariantem zanurzeniowym M76S+ jako liderami pod względem efektywności w całej serii M70.

Hydro cooling uses closed loop water circulation through internal channels in a sealed 4U chassis. The M73S+ does not submerge in fluid. Water absorbs heat inside the chassis and carries it to an external cooling loop through standard plumbing. Units install in 19 inch server racks alongside other data center equipment. Immersion cooling submerges the entire miner in dielectric fluid held in specialized tanks. The M73S+ hydro approach uses off the shelf pumps, standard plumbing, and common water glycol coolant. Immersion requires specialized dielectric fluid at higher cost per liter, custom tank infrastructure, and more complex fluid quality management.

Infrastructure familiarity and integration. Facilities already operating liquid cooled compute servers (data centers, colocation facilities, enterprise IT environments) have water cooling expertise and equipment. Adding M73S+ units extends existing infrastructure rather than building dedicated immersion tank systems. Standard 19 inch server racks and water lines fit into existing facility architecture. Immersion makes more sense for dedicated mining facilities purpose built around tanks, or operations where the density advantage of 19 M76S+ units per 100 kW panel outweighs the custom infrastructure cost.

Trzy zbiorniki na rakiecie M73 do montażu w racku na poziomie hydro. Podstawa M73: 470 TH/s przy 14,5 J/TH. M73S środkowy: 500 TH/s przy 13,5 J/TH. M73S+ górny (ten produkt): od 540 do 600 TH/s przy 12,5 J/TH. Wszystkie trzy mają identyczną obudowę 4U, moc znamionową 7200W, wymagania na trzyfazowe zasilanie 380 do 480V oraz architekturę chłodzenia wodnego. Ranga chipów różni je pod względem jakości. M73S+ oferuje o 15 procent więcej mocy obliczeniowej niż podstawowy model M73 przy o 14 procent lepszej wydajności, co wiąże się z ceną premium za chipy najwyższej klasy.

380 to 480V three phase commercial or industrial power. At 415V three phase: approximately 17 amps per phase in rated 7,200W mode, or 24 amps per phase in overclock 10,000W mode. At 480V three phase: approximately 15 amps in rated mode, 21 amps in overclock mode. Rated mode fits standard 20 amp commercial breakers. Overclock mode requires 32 amp breakers for reliable operation. Not suitable for standard residential or small commercial electrical systems. European, Middle Eastern, and industrial Asian facilities at 380 to 415V three phase have direct deployment paths.

Zamknięty obieg wody z użyciem dostępnych na rynku komponentów. Wymagane: pompy obiegowe o rozmiarze dostosowanym do łącznego przepływu floty, standardowe elementy hydrauliczne (bez specjalistycznych złączek do immersji), mieszanka chłodziwa wodno-glikolowego, zewnętrzna redukcja ciepła za pomocą chłodni suchych lub wymienników ciepła wody na wodę, oraz filtracja liniowa. Pojemność chłodziwa w przybliżeniu od 2 do 4 litrów na jednostkę plus pojemność zbiornika systemowego. Każdy M73S+ generuje około 24 570 BTU na godzinę ciepła do odprowadzenia. W przypadku wdrożenia na skalę rack z wieloma jednostkami, odprowadzanie ciepła rośnie proporcjonalnie i korzysta ze standardowego sprzętu chłodniczego dostępnego u dowolnego dostawcy przemysłowego.

A standard 42U rack holds 10 M73S+ units (factoring space for cooling manifolds and cable management) producing 5.4 PH/s at 72 kW per rack. Compare against the M76S+ immersion option (19 units in tanks per 100 kW producing 7,410 TH/s) or M79S hydro 3U option (7 units per 100 kW producing 6,510 TH/s). The M73S+ rack mount approach wins on infrastructure familiarity and standard server rack integration. Immersion wins on aggregate hashrate per kilowatt of electrical capacity.

At MillionMiner's $0.08 per kWh onsite calculator: $17.64 daily revenue, $13.82 electricity, $3.81 net profit per day. At $0.07 per kWh industrial rates: approximately $12.10 daily electricity against similar revenue, netting $5 to $6 daily. At $0.04 per kWh negotiated industrial rates: $6.91 daily electricity, netting $10 to $11 daily profit per unit. At upper bin 600 TH/s output, daily revenue improves 11 percent over the 540 TH/s floor. Run overclock mode calculations against your electricity rate because the 2.8 kW additional draw must recover through proportional revenue gains.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), and DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools like ViaBTC and F2Pool adds marginal secondary revenue.

Industrial deployment with three phase power and water cooling infrastructure. Step one: install three phase 380 to 480V electrical service. Step two: install and commission water cooling loop including pumps, plumbing, dry coolers, and initial coolant fill. Step three: rack mount M73S+ units in standard 19 inch racks and connect water inlet/outlet fittings to your manifold system. Verify zero leaks before energizing. Step four: connect PSU power and Ethernet management. Step five: power on, allow coolant flow to stabilize, find each miner IP through DHCP, configure pool URL and Bitcoin wallet through the Whatsminer web interface, verify hashrate reaches 524+ TH/s within 15 to 20 minutes per unit.

Yes, with appropriate infrastructure provisioning. Overclock mode scales the M73S+ to 10,000W and approximately 600 TH/s output. Requirements for stable overclock operation: electrical circuits sized for 32 amp per phase draw rather than 20 amp, water cooling loop with additional thermal margin (25 to 30 percent above rated mode capacity), and electricity pricing that makes the additional draw economically worthwhile. The 2.8 kW additional power in overclock mode must generate proportional hashrate gains to justify the electricity cost. At $0.04 per kWh industrial rates, overclock typically wins daily margin. At $0.08 per kWh or above, rated mode often delivers better net profit.

Water cooling maintenance. Weekly visual inspection of all fittings for leaks or corrosion. Monthly coolant quality testing (pH within spec, particulate levels minimal). Every 12 to 24 months full coolant replacement depending on fluid chemistry. Quarterly pump and dry cooler inspection. Inline filter replacement when pressure differential exceeds specification. Hashboard failure rates on hydro units run lower than air cooled because chips operate at consistent temperatures. Water cooling maintenance is simpler than immersion fluid management because water glycol is cheaper and more widely available than dielectric fluid.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network share. F2Pool has the longest operational track record and supports merged mining. AntPool remains popular across MicroBT fleets. ViaBTC offers accumulation mode payouts. For fleet deployments above 5 PH/s (equivalent to 10+ M73S+ units), direct negotiated agreements with major pools typically secure reduced fees below standard rates.

Different deployment scales. M73S+: 540 to 600 TH/s at 7,200 to 10,000W and 12.5 J/TH headline in 4U chassis. Antminer S23 Hyd 3U: 1,160 TH/s at 11,020W and 9.5 J/TH in 3U chassis. Bitmain's S23 Hyd 3U leads on absolute hashrate per unit and efficiency per terahash. The M73S+ fits facilities wanting hydro mining at mid power tier with broader bin flexibility. For operations building dedicated petahash class deployment, the S23 Hyd 3U is the more aggressive choice. For operations integrating hydro mining into existing data center infrastructure at comfortable per unit scale, the M73S+ fits better.

Gwarancja fabryczna MicroBT na 360 dni obejmuje całą maszynę i chroni przed wadami produkcyjnymi oraz awariami sprzętu podczas normalnej eksploatacji w określonych zakresach środowiskowych. Wyłączenia gwarancyjne obejmują uszkodzenia spowodowane zaniedbaniem jakości płynu chłodzącego, wycieki powodowane nieprawidłowym montażem elementów, uszkodzenia mechaniczne podczas konserwacji układu chłodzenia, uszkodzenia spowodowane przepięciami z powodu niewystarczającej ochrony elektrycznej oraz eksploatację poza zakresem temperatur od 5 do 45 stopni Celsjusza. Dokumentuj harmonogram testów płynu chłodzącego oraz dzienniki konserwacji, aby zabezpieczyć pokrycie gwarancją.

Yes. MillionMiner operates managed hosting facilities with three phase industrial power and water cooling infrastructure capable of supporting M73S+ deployments. Hosted deployment eliminates facility infrastructure CapEx. Professional hosting at negotiated industrial rates often beats self hosting when full infrastructure costs are included. Contact MillionMiner sales through the Get a Quote button for hosting pricing, capacity availability, and deployment timelines.

Standard Whatsminer firmware provides the same web interface, pool configuration format, and management API as other MicroBT miners. Fleet management tools including Foreman, Awesome Miner, Hive OS, and Braiins OS+ discover M73S+ units automatically through network scanning. Additional monitoring metrics for hydro operation (coolant flow rate, inlet/outlet temperatures) appear in hydro specific dashboards. Mixed brand and cooling type fleets handle through unified dashboards.

CapEx additions beyond miner acquisition: three phase electrical service installation ($5,000 to $20,000 per facility), water cooling loop and pumps ($5,000 to $20,000 per rack depending on capacity), racks and cabling ($1,500 to $4,000 per rack). Annual OpEx per unit at 7.2 kW rated: electricity at $5,045 at $0.08 per kWh, $2,522 at $0.04 per kWh industrial rates, water glycol coolant maintenance ($100 to $300 per unit annually), spare parts and maintenance. Water cooling infrastructure CapEx runs meaningfully lower than immersion tank systems, which is the primary economic argument for rack mount hydro over immersion deployment.

No. The M73S+ requires 380 to 480V three phase industrial power unavailable in residential settings, water cooling loop infrastructure, and professional installation for both electrical service and plumbing. Home mining hardware caps at around 3,500W per unit on standard 240V 20A circuits. For high hashrate home deployment, the Antminer S21 XP at 270 TH/s represents the realistic ceiling. The M73S+ is strictly industrial hardware for professional mining facilities and data centers.

Within the M73 rack mount hydro tier: the Whatsminer M73S at 500 TH/s and M73 at 470 TH/s provide lower bin alternatives in the same chassis. Cross cooling at MicroBT: immersion variants M76 and M78 series cover alternative liquid cooling for facilities with tank infrastructure, M79 and M79S cover high power hydro tier (14 kW and 20 kW per unit). Cross brand hydro: the Bitmain Antminer S23 Hyd 3U at 1.16 PH/s provides vendor diversification at higher power tier. For algorithm diversification, the Antminer KS7 at 45 TH/s covers Kaspa mining. MillionMiner's ASIC hosting service accepts M73S+ units at negotiated industrial electricity rates.