Bitmain
Model: Antminer L9 Hyd 2U
Bitmain's hydro cooled rack mount Scrypt ASIC miner (Bitmain SKU U2L9H) for Litecoin (LTC), Dogecoin (DOGE), and Bellscoin (BELLS) merged mining. 27 GH/s Scrypt at 5,670W and 0.21 J/MH efficiency in a 2U rack chassis. Previous generation to the L11 Hyd 2U (35 GH/s) at lower acquisition cost, same 2U format for mixed rack deployment during fleet transitions. 50 dB liquid to chip cooling versus 75 dB air cooled L9. 380 to 415V three phase industrial input. 445 x 88 x 670 mm chassis. Merged mining delivers LTC, DOGE, and BELLS simultaneously from 27 GH/s, typically 20 to 40 percent higher combined revenue than solo LTC. Ships with PSU, cables, 6 month Bitmain warranty, and free DDP worldwide from MillionMiner.
Select Availability
Quantity
$6,900.00
Buying 10 or more? Get custom bulk pricing
Genuine
Tested hardware
Worldwide
Global shipping
Support
Mining experts
Hashrate
27 GH/s
Power
5670 W
Efficiency
210.00 J/GH
Noise
50 dB
Based on current BTC price & network difficulty. Indicative only.
| Period | Daily | Weekly | Monthly |
|---|---|---|---|
|
Income
|
$9.46 | $66.22 | $283.80 |
|
Electricity
|
-$6.80 | -$47.60 | -$204.00 |
|
Profit
|
$2.66 | $18.62 | $79.80 |
Using 0.050 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: Jun 10, 2026. Estimates at $0.08/kWh.
Industrial-scale hydro deployments where efficiency and density beat upfront cost.
Contents may vary by batch. Exact items listed in order confirmation.
Connect PSU to miner and plug into the outlet
Connect ethernet cable to your router or switch
Find miner IP via router admin or IP scanner tool
Open web interface, enter pool URL and wallet — start mining
Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
The Bitmain Antminer L9 Hyd 2U (Bitmain SKU U2L9H) is a hydro cooled rack mount Scrypt ASIC miner for Litecoin and Dogecoin merged mining. 27 GH/s Scrypt at 5,670W continuous draw and 0.21 J/MH (210 J/GH) efficiency. ±3 percent hashrate tolerance and ±5 percent power tolerance. 2U rack mount chassis at 445 x 88 x 670 mm. 380 to 415V three phase input with approximately 12A maximum current per phase and 50 to 60Hz frequency range. 50 dB liquid to chip cooling. 5 to 45 degrees Celsius operating range. Ethernet 10/100M management through standard Bitmain firmware. Scrypt generational context: L3+ at 504 MH/s, L7 at 9.5 GH/s, L9 at 17 GH/s air cooled, L9 Hyd 2U at 27 GH/s, L11 at 20 to 21 GH/s air cooled, L11 Hyd 2U at 35 GH/s, L11 HU6 at 33 GH/s. The L9 Hyd 2U sits as the hydro cooled variant of the L9 platform, delivering approximately 59 percent more hashrate than the air cooled L9 through hydro cooling's ability to sustain higher chip power density without thermal throttling. Efficiency remains at the L9 family 0.21 J/MH baseline, approximately 18 percent worse per megahash than the newer L11 family at 0.172 to 0.184 J/MH. Fleet transition value distinguishes the L9 Hyd 2U at current generation pricing. The 2U rack mount format matches the newer L11 Hyd 2U exactly, allowing mixed rack deployment during gradual L9 to L11 fleet transitions. Similar water cooling plumbing connections simplify infrastructure conversions. Operations can deploy L9 Hyd 2U units at lower capital cost for immediate hashrate expansion, then migrate selected slots to L11 Hyd 2U as budget cycles and fleet refresh permit. This transition flexibility is specific to rack mount hydro fleet operators and does not apply to operators choosing between air cooled and hydro deployment tiers. Rack density analysis. 21 L9 Hyd 2U units fit per standard 42U rack, producing 567 GH/s total Scrypt hashrate at approximately 119 kW continuous power per rack. The newer L11 Hyd 2U at 35 GH/s per unit produces 735 GH/s per rack at similar power density. The L9 Hyd 2U delivers 23 percent less per rack hashrate than the L11 Hyd 2U at lower acquisition cost per unit. For facilities planning staged deployment or operators preferring deeper amortization on mature hardware, the L9 Hyd 2U delivers the rack mount hydro entry tier. Scrypt merged mining produces Litecoin, Dogecoin, and Bellscoin simultaneously from the same 27 GH/s hashrate through configured merged mining pools. Combined revenue typically runs 20 to 40 percent above solo LTC at the same hashrate. Luckycoin, Junkcoin, and Pepecoin also merge mine at varying pool support. Three to six coin simultaneous output from one device is a structural Scrypt advantage that SHA-256 Bitcoin mining and most other algorithms cannot match. Acoustic characteristics: 50 dB liquid to chip cooling versus 75 dB on air cooled L9 units, roughly 75 percent less perceived loudness. In shared data center environments or facilities with on site staff, the 50 dB level means staff can work around deployed hardware without hearing protection. Air cooled 75 dB deployment typically requires hearing protection for extended exposure and creates tenant complaints in multi tenant facilities. Hydro infrastructure requirements. Unlike the L11 HU6 with integrated all in one cooling, the L9 Hyd 2U requires external facility hydro infrastructure: coolant distribution unit (CDU), dry cooler or chiller, heat exchanger, pumps, and plumbing connecting miner cold plates to facility cooling loops. Deployment requires existing hydro infrastructure or facility CapEx to build it. For facilities without existing hydro capacity, the integrated L11 HU6 or air cooled L11 Pro represent alternatives that avoid the facility infrastructure requirement. Power infrastructure. 380 to 415V three phase industrial input at approximately 12A maximum current per phase. Not available in residential or most light commercial settings. Purpose built for professional mining facilities with three phase power distribution, water cooling loops, and 2U rack infrastructure. Ships with PSU, power cables, quick start guide, 6 month Bitmain factory warranty, and free DDP worldwide delivery from MillionMiner.
The Antminer L9 Hyd 2U (Bitmain SKU U2L9H) is Bitmain's hydro cooled rack mount Scrypt ASIC miner. 27 GH/s Scrypt at 5,670W and 0.21 J/MH efficiency in a 2U rack chassis. The previous generation to the L11 Hyd 2U (35 GH/s), offering lower acquisition cost at reduced performance per unit. Fleet transition value sets the L9 Hyd 2U apart. The 2U rack mount format matches the newer L11 Hyd 2U, allowing mixed rack deployment during gradual L9 to L11 fleet transitions. Similar water cooling connections simplify plumbing conversions. Operations can deploy L9 Hyd 2U units today at lower capital cost, then migrate selected slots to L11 Hyd 2U as budget and fleet refresh cycles permit. 21 units per 42U standard rack at 567 GH/s total per rack. L11 Hyd 2U produces 735 GH/s per rack at 23 percent higher density. The L9 Hyd 2U delivers the lower capital entry point into rack mount hydro Scrypt deployment. Scrypt merged mining delivers LTC, DOGE, and BELLS simultaneously from 27 GH/s, typically 20 to 40 percent higher combined revenue than solo LTC. 50 dB liquid to chip cooling versus 75 dB air cooled L9. 380 to 415V three phase industrial input with approximately 12A maximum current per phase. 445 x 88 x 670 mm chassis.
Our mining specialists can help you find the perfect miner for your setup and budget.
Bitmain's hydro cooled rack mount Scrypt ASIC (Bitmain SKU U2L9H). 27 GH/s at 5,670W and 0.21 J/MH efficiency in a 2U rack chassis. Previous generation to the L11 Hyd 2U (35 GH/s) at lower acquisition cost, same 2U format for mixed rack deployment during L9 to L11 fleet transitions. 21 units per 42U rack at 567 GH/s total. 50 dB liquid to chip cooling versus 75 dB air cooled L9. 380 to 415V three phase industrial input. 445 x 88 x 670 mm chassis. Merged mining delivers LTC, DOGE, and BELLS simultaneously from 27 GH/s, typically 20 to 40 percent higher combined revenue than solo LTC. Ships with PSU, cables, 6 month Bitmain warranty, and free DDP worldwide.
59 percent more hashrate than the air cooled L9 through hydro cooling. 0.21 J/MH efficiency on 5,670W in a 2U rack chassis.
Same 2U rack mount format as the L11 Hyd 2U. Mixed rack deployment during L9 to L11 fleet transitions with similar plumbing connections.
Liquid to chip cooling drops noise to 50 dB versus 75 dB air cooled L9. Staff can work around deployed hardware without hearing protection.
27 GH/s Scrypt at 5,670W continuous draw and 0.21 J/MH (210 J/GH) efficiency. Bitmain's ±3 percent tolerance produces real world output between 26.2 and 27.8 GH/s. 59 percent more hashrate than the air cooled L9 at 17 GH/s through hydro cooling's ability to sustain higher chip power density.
2U rack mount chassis at 445 x 88 x 670 mm per MillionMiner's specification. The 88 mm chassis height corresponds to 2U in standard 19 inch rack measurement. Fits standard server racks without custom mounting hardware. 21 units per 42U rack produces 567 GH/s total.
50 dB from the liquid to chip cooling design, roughly 75 percent less perceived loudness than the 75 dB air cooled L9. Staff can work around deployed hardware without hearing protection. Air cooled L9 deployment typically requires hearing protection for extended exposure.
External facility hydro infrastructure required. Unlike the L11 HU6 with integrated all in one cooling, the L9 Hyd 2U connects to external coolant distribution unit (CDU), dry cooler or chiller, heat exchanger, pumps, and plumbing. Deployment requires existing hydro capacity or facility CapEx to build it. For facilities without existing hydro infrastructure, the L11 HU6 (integrated cooling) or air cooled L11 Pro are alternatives.
380 to 415V three phase industrial input with approximately 12A maximum current per phase and 50 to 60Hz frequency range. Not available in residential or most light commercial settings. Purpose built for professional mining facilities with three phase power distribution.
All Scrypt algorithm cryptocurrencies through merged mining. Primary coins: Litecoin (LTC), Dogecoin (DOGE), Bellscoin (BELLS). Additional Scrypt coins: Luckycoin (LKY), Junkcoin (JKC), Pepecoin (PEP). Combined revenue typically runs 20 to 40 percent above solo LTC at the same hashrate.
21 units per 42U standard rack at 567 GH/s total Scrypt hashrate and approximately 119 kW continuous power per rack. Compared to the newer L11 Hyd 2U at 35 GH/s per unit (735 GH/s per rack, 23 percent higher density), the L9 Hyd 2U delivers the lower capital entry tier into rack mount hydro Scrypt deployment.
Yes. MillionMiner hosting services accept L9 Hyd 2U units at managed facilities with three phase power and existing hydro cooling infrastructure. The 380 to 415V input and 5,670W draw align with industrial hosting standards. Contact MillionMiner for hosting rate tiers and availability.
6 month Bitmain factory warranty on new units. Box contents: Antminer L9 Hyd 2U, PSU, power cables, and quick start guide. Ships from MillionMiner with free DDP worldwide delivery covering all customs clearance, import duties, and taxes.
L9 Hyd 2U at 27 GH/s, 5,670W, and 0.21 J/MH. L11 Hyd 2U at 35 GH/s, 5,676W, and 0.162 J/MH. The L11 Hyd 2U delivers 30 percent more hashrate at essentially flat power (23 percent better efficiency per megahash) in the same 2U chassis format. Same water cooling connections allow mixed rack deployment during L9 to L11 fleet transitions. The L9 Hyd 2U trades hashrate and efficiency for lower acquisition cost per unit.
Air cooled L9 at 17 GH/s, 3,570W, and 0.21 J/MH. L9 Hyd 2U at 27 GH/s, 5,670W, and 0.21 J/MH. Same BM1485 chip architecture and same efficiency per megahash. Hydro cooling enables 59 percent more hashrate per unit through sustained higher chip power density without thermal throttling. Power draw increases proportionally to hashrate gain. The hydro variant trades air cooled deployment simplicity for rack mount density and 50 dB acoustic advantage.
L9 Hyd 2U at 27 GH/s, 5,670W, 0.21 J/MH in a 2U chassis requiring external facility hydro. L11 HU6 at 33 GH/s, 5,676W, 0.172 J/MH with integrated all in one cooling eliminating external facility infrastructure. The L11 HU6 delivers 22 percent more hashrate at 18 percent better efficiency and removes the facility hydro CapEx barrier. The L9 Hyd 2U offers 2U rack density advantage (21 units per 42U rack vs 7 units) for facilities with existing hydro capacity.
445 x 88 x 670 mm chassis at 20 kg per MillionMiner's specification. Alternative distributor documentation (Mining Now, CryptoMinerBros) lists 509 x 481 x 87 mm at 19.1 kg. The slight dimensional and weight discrepancy may reflect shipping packaging versus bare chassis. Verify with MillionMiner for logistics planning.
No. The 380 to 415V three phase input is not available in residential settings. 5,670W continuous draw requires industrial electrical service with three phase distribution. The 2U rack mount chassis requires 19 inch rack infrastructure. External hydro cooling loop requires facility infrastructure. For quiet home Scrypt mining, Fluminer L3 at 9.5 GH/s and 45 dB or Fluminer L1 Pro at 6 GH/s and 45 dB are appropriate options.
5 to 45 degrees Celsius at 5 to 95 percent humidity per MillionMiner's specification. Alternative distributor documentation (CryptoMinerBros) specifies 20 to 50 degrees Celsius reflecting hydro cooling's need for coolant to stay above condensation dew points. For cold climate deployments with facility temperatures below 20 degrees Celsius, verify coolant specification with Bitmain documentation.
Four step setup. Verify 380 to 415V three phase service capable of 5,670W continuous. Connect PSU to miner. Connect water cooling inlet and outlet to facility CDU or cooling loop. Connect Ethernet. Find miner IP, open Bitmain web interface, configure Scrypt merged mining pool URL and LTC/DOGE/BELLS wallet addresses, change default credentials. Verify hashrate reaches 26+ GH/s within 10 minutes.
Major Scrypt merged mining pools accept L9 Hyd 2U hashrate including F2Pool, Poolin, ViaBTC, Prohashing, Litecoinpool. Pool fees typically 0.5 to 2 percent. Verify Bellscoin support before deployment since not all Scrypt pools have added BELLS.
Third party Scrypt firmware support is less mature than SHA-256. Most L9 Hyd 2U operators run stock Bitmain firmware. Some BraiinsOS style tuning has targeted earlier Scrypt hardware but L9 Hyd 2U specific deployment is limited. Plan for stock Bitmain firmware operation.
Pro factors: lower acquisition cost than current generation L11 hydro, 2U rack format matches L11 Hyd 2U for fleet transition flexibility, 50 dB acoustic advantage over air cooled, mature Bitmain firmware ecosystem, 21 units per 42U rack density. Con factors: L11 family delivers 18 to 23 percent better efficiency per megahash, requires external facility hydro infrastructure (L11 HU6 eliminates this), 380 to 415V three phase excludes non industrial facilities. For facilities with existing rack mount hydro infrastructure prioritizing capital efficiency over latest generation performance, the L9 Hyd 2U delivers competitive fleet expansion economics.
For Scrypt family upgrades: L11 Hyd 2U (35 GH/s) drops into the same rack slots with better efficiency, L11 HU6 (33 GH/s) offers integrated all in one cooling eliminating facility hydro infrastructure, air cooled L11 Pro (21 GH/s) and L11 base (20 GH/s) for facility zones without hydro. For algorithm diversification: Antminer S21 XP (270 TH/s), S23 (318 TH/s), or S23E Hyd 2U (865 TH/s) cover SHA-256 Bitcoin with similar three phase hydro deployment. Antminer KS7 (45 TH/s) covers Kaspa KHeavyHash. For quiet Scrypt on separate infrastructure: Fluminer L3 (9.5 GH/s, 45 dB) or Fluminer L1 Pro (6 GH/s, 45 dB). Bitdeer SEALMINER DL1 Air (25 GH/s) provides air cooled vendor diversification. MillionMiner's ASIC hosting service covers turnkey L9 Hyd 2U deployment without facility CapEx.