In Stock

Bitmain

Bitmain Antminer S23 Hyd 3U (1.16PH)

Model: Antminer S23 Hyd 3U

New

Bitmain's flagship current generation Bitcoin miner at 1.16 PH/s (1,160 TH/s) SHA-256 hashrate in a single 3U rack mount chassis, crossing the petahash barrier per unit. 11,020W power draw at 9.5 J/TH efficiency, matching the S23 Hydro 580TH standalone variant on efficiency while doubling hashrate density through the 3U form factor. Announced mid-2025 with batch shipping from January 2026. Replaces entire racks of previous generation hardware with single units: where S19 era deployments needed 40+ units for petahash capacity, the S23 Hyd 3U achieves this with one. 14 units per 42U rack produce 16.24 PH/s per cabinet at approximately 154 kW. LP34 industrial three phase power connector. 380 to 415V three phase service required. 50 dB chassis noise (external cooling infrastructure adds separate acoustic signature). 900 x 486 x 132 mm at 21.5 kg. Operating temperature 5 to 45 degrees Celsius at 5 to 95 percent humidity. ±3% hashrate and ±5% power tolerance. Ships with PSU, 365 day Bitmain warranty, and free DDP worldwide from MillionMiner.

1160 TH/s 11020W SHA-256 9.5 J/TH

Select Availability

Quantity

Total Price

$32,379.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bank Transfer | BTC | ETH | USDT

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Hashrate

1160 TH/s

Power

11020 W

Efficiency

9.50 J/TH

Noise

50 dB

Estimated Mining Returns

Based on current BTC price & network difficulty. Indicative only.

Period Daily Weekly Monthly
Income
$46.15 $323.05 $1,384.50
Electricity
-$13.22 -$92.54 -$396.60
Profit
$32.93 $230.51 $987.90

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: May 20, 2026. Estimates at $0.08/kWh.

Full Specifications

Hashrate 1160 TH/s
Power Consumption 11020 W
Efficiency 9.50 J/TH
Algorithm SHA-256
Model Antminer S23 Hyd 3U
Release Year Jun 2025
Noise Level 50 dB
Dimensions 900 x 486 x 132mm
Weight 21.5 kg
Voltage 380~415V AC
Interfaces Ethernet
Operating Temp 5 - 45 °C
Humidity 5 - 95 %
Cooling Type Hydro
Rack Format 3U

What's in the Box

Antminer S23 Hyd 3U
Power supply unit (PSU)
Power cables
Quick start guide

Contents may vary by batch. Exact items listed in order confirmation.

Quick Setup

1

Connect PSU to miner and plug into the outlet

2

Connect ethernet cable to your router or switch

3

Find miner IP via router admin or IP scanner tool

4

Open web interface, enter pool URL and wallet — start mining

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
star star star star star

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso made-in-germany trustpilot
google-review

Get a Quote for the Bitmain Antminer S23 Hyd 3U (1.16PH)

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Product Details

Bitmain Antminer S23 Hyd 3U 1.16 PH/s Flagship Industrial Hydro Cooled Petahash Bitcoin Miner: Complete Specifications, Deployment Analysis, and Fleet Economics

The Bitmain Antminer S23 Hyd 3U is the flagship of Bitmain's current
Bitcoin mining lineup and the first production hardware to cross the petahash barrier in a single
chassis. 1.16 PH/s (1,160 TH/s) SHA-256 hashrate at 11,020W continuous power draw and 9.5
J/TH efficiency. Announced by Bitmain in mid-2025, with batch shipping beginning January 2026
per OneMiners and BT-Miners distribution documentation. ±3% hashrate tolerance means real
world output ranges 1,125 to 1,195 TH/s. ±5% power tolerance means wall draw can reach
11,571W at peak.
The petahash per unit milestone matters for industrial mining economics. Prior generation
hardware required multi unit deployments to reach petahash aggregate capacity. A single S23
Hyd 3U at 1.16 PH/s replaces approximately 40+ Antminer S19 generation units (each at 100
TH/s), 4.3 Antminer S21 XP 270TH air cooled units, or 2 standalone S23 Hydro 580TH units.
The consolidation reduces per petahash infrastructure overhead: fewer cables, fewer Ethernet
connections, fewer water fittings, fewer management endpoints, lower aggregate failure rate on
cable and connection components. For facilities optimizing aggregate hashrate per rack unit,
per square foot, or per cooling kilowatt, the S23 Hyd 3U redefines the benchmark.
Efficiency at 9.5 J/TH places the S23 Hyd 3U in the elite tier alongside the standalone S23
Hydro 580TH. This is Bitmain's current efficiency floor, substantially improved over prior
generation hardware: S21 XP Hydro 473TH at 12 J/TH, S21+ Hydro 395TH at 15 J/TH, air
cooled S23 at 11 J/TH. The efficiency leadership compounds into meaningful electricity cost
savings at scale. At $0.07 per kWh industrial rates, switching from 12 J/TH hardware to 9.5 J/TH
saves approximately $28 per TH per year in electricity. Across a single S23 Hyd 3U at 1,160
TH/s, this represents $32,000 annual electricity savings versus equivalent hashrate in prior
generation hardware.
Power infrastructure requirements are strictly industrial. 380 to 415V three phase service with
LP34 industrial power connector (specified in Bitmain's product manual). At 415V three phase:
approximately 15 amps per phase continuous, 25 amps per phase at peak draw. At 380V three
phase: approximately 17 amps per phase continuous, 29 amps per phase at peak. Requires
dedicated 32 amp three phase breakers minimum for reliable continuous operation. LP34
connector specification excludes standard commercial single phase deployment entirely. This is
strictly industrial hardware for professional data center and dedicated mining facility deployment.
Cooling infrastructure requirements match the scale of thermal output. Each S23 Hyd 3U
generates approximately 11 kW thermal load (37,520 BTU per hour), requiring substantial
external cooling capacity. Closed loop water cooling system with controlled inlet temperature
management, circulation pumps sized for aggregate fleet flow rate, dry cooler or water to water
heat exchanger capacity matching total thermal load, inline particulate filtration, and automated
flow monitoring. Inlet water temperature must remain above 20 degrees Celsius for miner
startup (hardware protection interlock identical to the S23 Hydro 580TH). Dry cooler
specifications tie maximum facility ambient temperature to outlet water temperature: 35 degrees
outlet equals 30 degrees ambient ceiling, 45 degrees outlet equals 40 degrees ambient ceiling.
Rack density math demonstrates the flagship positioning. A full 42U rack holds 14 S23 Hyd 3U
units at 3U each (after accounting for manifold space and cable management), producing 16.24
PH/s per cabinet at approximately 154 kW total power draw. Compare against alternatives at
the same rack space. 42U of S23 Hydro 580TH standalone: approximately 30 units producing
17.4 PH/s at 165 kW (slightly higher aggregate hashrate but requires individual shelf hardware
rather than 3U rack format). 42U of S21 XP Hydro 473TH: approximately 21 units producing
9.93 PH/s at 119 kW (meaningfully lower aggregate). The S23 Hyd 3U wins on rack format
efficiency and aggregate hashrate per cabinet.
Fleet deployment at 100 kW industrial panel: approximately 9 S23 Hyd 3U units producing
10.44 PH/s. Compare against 100 kW of S23 Hydro 580TH standalone: 18 units producing
10.44 PH/s (identical aggregate at different form factor). 100 kW of S21 XP Hydro 473TH: 17
units producing 8.04 PH/s (23 percent less aggregate). At fleet scale, the S23 Hyd 3U delivers
the same efficiency as the standalone S23 Hydro while consolidating management overhead to
half the unit count.
50 dB chassis noise reflects the absence of high speed cooling fans in the hydro architecture.
External cooling infrastructure adds separate acoustic signature (55 to 70 dB typical) depending
on equipment selection and physical placement. Professional hydro cooled mining facilities
specifically isolate miner deployment space from cooling plant locations to minimize acoustic
impact on mining operations and meet municipal noise requirements.
Physical specifications: 900 x 486 x 132 mm at 21.5 kg. Standard 3U rack mount format
compatible with 19 inch server racks and industrial mining facility cabinets. Verify rack depth
capability before ordering (900 mm chassis depth exceeds standard 1000 mm rack depth with
minimal clearance and may require deeper industrial racks for proper cable management).
Ethernet 10/100M management through standard Bitmain firmware with Foreman, Awesome
Miner, Hive OS, and Braiins OS+ fleet management compatibility. Same firmware codebase as
S23 Hydro standalone and air cooled S23 variants.
Real world profitability in April 2026 varies meaningfully with electricity rate tier. Minerstat April
10, 2026: $37.68 daily Bitcoin revenue at current network conditions. MillionMiner $0.08 per
kWh onsite calculator: $37.79 daily revenue, $21.16 electricity, $16.63 daily net profit. ASIC
Miner Value at $0.10 per kWh: $10.47 daily profit per unit. OneMiners April to August 2025 data
at $0.04 per kWh negotiated industrial hosting: $68 to $95 daily earnings, averaging $81.30.
ROI estimates: 8 to 13 months at $0.04 per kWh hosting per OneMiners, extending to 18 to 36
months at $0.08 per kWh commercial rates depending on BTC price scenarios. At BTC prices
above $160,000, daily profit projections exceed $40 per unit at current electricity assumptions.
Ships with PSU, 365 day Bitmain factory warranty, and free DDP worldwide delivery from
MillionMiner. Market pricing for the S23 Hyd 3U across distributor channels ranges $28,000 to
$32,500 per unit with MillionMiner at the premium end reflecting full warranty routing and free
DDP delivery including customs clearance.

Bitmain Antminer S23 Hyd 3U 1.16 PH/s: The Current Generation Petahash

The S23 Hyd 3U is Bitmain's most powerful current Bitcoin miner,
delivering 1.16 PH/s (1,160 TH/s) SHA-256 hashrate in a single 3U rack mount chassis. This
crosses the petahash barrier per unit, a capability unavailable in any prior generation Bitcoin
mining hardware. 11,020W power draw at 9.5 J/TH efficiency matches the standalone S23
Hydro 580TH on per terahash efficiency while doubling hashrate density through the 3U format.
The infrastructure consolidation math is substantial. A single S23 Hyd 3U replaces
approximately 40+ S19 generation units (each at 100 TH/s) or approximately 3 Antminer S21
XP 270TH air cooled units. Where previous generation petahash capacity required dedicated
rack space for multiple machines, the S23 Hyd 3U achieves this with one 3U unit. A full 42U
rack holds 14 units at 3U each, delivering 16.24 PH/s per cabinet at approximately 154 kW. For
facilities measuring aggregate hashrate per rack or per square foot, the S23 Hyd 3U moves the
benchmark substantially.
Infrastructure requirements are strictly industrial. 380 to 415V three phase power service
through an LP34 industrial connector. No single phase or residential deployment possible.
External water cooling loop with inlet temperature above 20 degrees Celsius for startup. Dry
cooler or heat exchanger infrastructure rated for 11 kW thermal load per unit (37,520 BTU per
hour). Multi unit deployments scale cooling infrastructure proportionally, typically through
manifold distribution with individual unit isolation valves.
Announced mid-2025 with batch shipping starting January 2026. ±3% hashrate tolerance means
real output ranges 1,125 to 1,195 TH/s. ±5% power tolerance means peak draw can reach
11,571W. Standard Bitmain firmware with Ethernet management, Foreman/Awesome
Miner/Braiins OS+ compatibility. Ships with 365 day Bitmain warranty.
Real world profitability per OneMiners April to August 2025 data at $0.04 per kWh hosting: $68
to $95 daily earnings averaging $81.30, with 8 to 13 month ROI. At $0.08 per kWh commercial
rates, MillionMiner calculator shows $16.63 daily net profit.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Bitmain Antminer S23 Hyd 3U 1.16 PH/s Petahash Class Hydro Bitcoin Miner

Bitmain's flagship Bitcoin miner crossing the petahash barrier in a single 3U
rack unit. 1.16 PH/s SHA-256 hashrate at 11,020W and 9.5 J/TH efficiency, matching the S23
Hydro 580TH on efficiency while doubling per unit hashrate through the 3U form factor.
Replaces entire racks of S19 generation hardware with single machines. 14 units per 42U rack
produce 16.24 PH/s per cabinet. LP34 industrial three phase power connector. 380 to 415V
three phase service required. 50 dB chassis operation. 900 x 486 x 132 mm at 21.5 kg. Batch
shipping from January 2026. Real world profitability per OneMiners April to August 2025 data at
$0.04 per kWh hosting: $68 to $95 daily earnings averaging $81.30, with 8 to 13 month ROI
estimates. MillionMiner $0.08 per kWh calculator: $16.63 daily net profit. Ships with 365 day
Bitmain warranty and free DDP worldwide.

1.16 PH/s Crossing the Petahash Barrier

First production Bitcoin miner delivering petahash output per unit. Replaces 40+ S19 era units or 4 S21 XP 270TH machines with single hardware.

9.5 J/TH Efficiency in 3U Rack Format

Matches S23 Hydro 580TH on efficiency while doubling per unit hashrate through 3U rack density. 16.24 PH/s per 42U cabinet at 154 kW.

LP34 Three Phase Industrial Only

380 to 415V three phase through LP34 industrial connector. External hydro cooling loop with 20°C minimum inlet. Data center or dedicated facility deployment.

FAQ

Frequently Asked Questions

1.16 PH/s (1,160 TH/s) of SHA-256 hashrate at 11,020W continuous power draw and 9.5 J/TH efficiency. Bitmain's ±3% hashrate tolerance means real world output ranges 1,125 to 1,195 TH/s. ±5% power tolerance means wall draw can reach 11,571W at peak. This matches the standalone S23 Hydro 580TH on per terahash efficiency while doubling per unit hashrate through the 3U form factor. Bitmain's most powerful current Bitcoin miner and the first production hardware to cross the petahash barrier in a single chassis.

Yes, this is near the top of current generation silicon capability. For context: S23 Hyd 3U and S23 Hydro 580TH at 9.5 J/TH represent Bitmain's efficiency leadership. Prior generation comparison: S21 XP Hydro 473TH at 12 J/TH (26 percent less efficient), S21+ Hydro 395TH at 15 J/TH (58 percent less efficient), air cooled S23 at 11 J/TH. At $0.07 per kWh industrial rates, each efficiency point in J/TH translates to approximately $28 per TH per year in electricity costs. Across 1,160 TH/s per S23 Hyd 3U, switching from 12 J/TH hardware saves approximately $32,000 annually per unit in electricity costs.

Form factor and hashrate density. S23 Hyd 3U (this product): 1,160 TH/s at 11,020W in a 3U rack mount chassis (900 x 486 x 132 mm, 21.5 kg). S23 Hydro 580TH: 580 TH/s at 5,510W in a compact standalone chassis (410 x 170 x 209 mm, 13.5 kg). Both deliver identical 9.5 J/TH efficiency. The 3U variant doubles hashrate per unit at double power draw, enabling rack consolidation and management overhead reduction. The standalone variant fits shelf or compact rack deployment at lower per unit cost. Choose based on facility rack infrastructure, aggregate hashrate targets, and management preferences across fleet size.

380 to 415V three phase industrial power service through an LP34 industrial connector (Bitmain's specified connector standard for this hardware). At 415V three phase: approximately 15 amps per phase continuous, 25 amps per phase at peak. At 380V three phase: approximately 17 amps per phase continuous. Requires dedicated 32 amp three phase breakers minimum. LP34 connector excludes standard commercial single phase or residential deployment entirely. This is strictly industrial hardware for professional data center and dedicated mining facility deployment. Facilities without three phase industrial electrical distribution cannot support this unit directly.

External closed loop water cooling system with substantial thermal capacity. Each unit generates approximately 11 kW thermal load (37,520 BTU per hour), requiring circulation pumps sized for fleet flow rate, dry cooler or water to water heat exchanger rated for total thermal load, inline particulate filtration, automated flow monitoring, and temperature management at inlet and outlet points. Critical constraint: inlet water temperature must remain above 20 degrees Celsius for miner startup (hardware protection interlock). Maximum facility ambient temperature scales with outlet water temperature per Bitmain's published curves. Multi unit deployments scale cooling infrastructure proportionally through manifold distribution with individual unit isolation valves for maintenance.

Approximately 40+ Antminer S19 generation units (each at 100 TH/s, totaling 4+ MW combined power). 4.3 Antminer S21 XP 270TH air cooled units. 2 Antminer S23 Hydro 580TH standalone units. 2.5 Antminer S21 XP Hydro 473TH units. The consolidation reduces management overhead meaningfully: fewer Ethernet connections, fewer water fittings, fewer PSU cables, lower aggregate cable failure rate, fewer firmware update endpoints. For facilities managing multi megawatt operations, consolidating petahash capacity to single units per 3U slot dramatically simplifies fleet management compared to maintaining dozens of lower output units.

42U rack holds 14 units at 3U each, producing 16.24 PH/s per cabinet at 154 kW total. 100 kW industrial electrical panel: approximately 9 units producing 10.44 PH/s aggregate. Compare alternatives. 100 kW of S23 Hydro 580TH standalone: 18 units producing 10.44 PH/s (identical aggregate, different form factor and unit count). 100 kW of S21 XP Hydro 473TH: 17 units producing 8.04 PH/s (23 percent less aggregate). 100 kW of S21+ Hydro 395TH: 17 units producing 6.72 PH/s (36 percent less aggregate). Per megawatt industrial panel: approximately 90 S23 Hyd 3U units producing 104 PH/s aggregate at current generation efficiency.

Any SHA-256 proof of work cryptocurrency. Bitcoin (BTC) is the primary target. Other compatible coins include Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), Namecoin (NMC), DigiByte (DGB SHA-256 chain). Merged mining BTC alongside BCH and BSV through supporting pools (ViaBTC, F2Pool) adds marginal secondary revenue without reducing Bitcoin hashrate contribution.

No. The 11,020W power draw requires 380 to 415V three phase industrial electrical service with LP34 industrial power connector, unavailable in residential settings. The 11 kW thermal load requires substantial external water cooling infrastructure impractical for residential installation. The 21.5 kg chassis weight and 900 mm depth require industrial grade rack hardware. This is strictly industrial hardware for professional mining facilities, commercial data centers, and dedicated hosting operations. For home deployment seeking hydro cooling, the Antminer S21+ Hydro 395TH with 100 to 240V universal single phase voltage represents the residential ceiling for hydro deployment.

Strong across electricity rate tiers. Minerstat April 10, 2026: $37.68 daily Bitcoin revenue. MillionMiner $0.08 per kWh calculator: $37.79 daily revenue, $21.16 electricity, $16.63 daily net profit. ASIC Miner Value at $0.10 per kWh: $10.47 daily profit. OneMiners April to August 2025 data at $0.04 per kWh industrial hosting: $68 to $95 daily earnings, averaging $81.30 per unit. ROI estimates: 8 to 13 months at $0.04 per kWh hosting per OneMiners, 18 to 36 months at $0.08 per kWh commercial rates depending on BTC price scenarios. Monthly net profit at $0.04 per kWh hosting: approximately $2,400 to $2,850 per unit.

50 dB chassis noise, which is effectively silent due to the absence of high speed cooling fans. The external cooling infrastructure generates acoustic signature separately: pumps typically run 45 to 55 dB, dry coolers and circulation plants typically run 55 to 70 dB depending on airflow requirements and physical design. Professional hydro cooled mining facilities specifically isolate miner deployment space from cooling plant locations to minimize acoustic impact. Total deployment noise depends on cooling infrastructure design rather than miner chassis. For industrial facilities with dedicated cooling plant rooms separated from mining deployment, operating noise in the miner room typically runs below 60 dB.

Industrial deployment with three phase power, LP34 connectors, and hydro cooling infrastructure. Step one: install dedicated 380 to 415V three phase electrical service with LP34 industrial connectors and 32 amp three phase breakers minimum. Step two: install and commission external hydro cooling loop with pumps, plumbing, coolant fill, dry cooler or heat exchanger rated for total thermal load, and temperature monitoring. Verify inlet water temperature capability above 20°C year round. Step three: rack mount S23 Hyd 3U units in 19 inch server racks (verify rack depth accommodates 900 mm chassis). Connect water inlet/outlet fittings to manifold system with individual isolation valves. Verify zero leaks before energizing. Step four: connect LP34 power cables and Ethernet management. Step five: power on, allow coolant flow to stabilize with inlet above 20°C, find miner IP through DHCP, configure pool URL and Bitcoin wallet through Bitmain web interface, verify hashrate reaches 1,125+ TH/s within 15 to 20 minutes per unit.

Industrial hydro cooling maintenance with emphasis on temperature management and water quality. Weekly visual inspection of water fittings for leaks. Monthly coolant quality testing. Every 12 to 24 months full coolant replacement. Quarterly pump and dry cooler inspection including flow rate verification. Inline filter replacement when pressure differential exceeds specification. Hashboard failure rates on hydro units run meaningfully lower than air cooled equivalents because chips operate at consistent temperatures. Temperature sensor calibration checks semi annually to ensure the 20°C inlet constraint operates correctly. LP34 connector inspection quarterly for corrosion or damage. Budget 3 to 5 percent of acquisition cost annually for maintenance reserves.

Bitmain 365 day factory warranty on the complete machine covering manufacturing defects and hardware failures under normal operation within specified environmental ranges. Warranty exclusions include damage from coolant quality neglect, leaks caused by improper fitting installation, physical damage during cooling loop maintenance, power surge damage from inadequate electrical protection, operation outside specified environmental ranges, and unauthorized firmware modifications. Document coolant testing schedule, inlet temperature logs, and maintenance records to protect warranty coverage. MillionMiner routes warranty claims through direct Bitmain channels.

Yes. MillionMiner operates managed hosting facilities with 380 to 415V three phase industrial power, LP34 industrial connectors, and hydro cooling infrastructure capable of supporting S23 Hyd 3U deployments. Hosted deployment eliminates facility infrastructure CapEx (three phase electrical service, LP34 industrial connectors, hydro cooling loop installation, dry cooler infrastructure) and leverages MillionMiner's negotiated industrial electricity rates typically $0.04 to $0.06 per kWh. At these hosted rates, OneMiners documents $68 to $95 daily earnings per unit during April to August 2025 operational data. Contact MillionMiner sales through the Get a Quote button for hosting pricing and deployment timelines.

Any Stratum compatible Bitcoin pool. Foundry USA leads by network hashrate share. F2Pool has the longest operational track record. AntPool is the native Bitmain ecosystem pool with deep firmware integration. ViaBTC offers accumulation mode payouts. Luxor supports hashrate derivatives products. For fleet deployments above 10 PH/s (equivalent to 9+ units or a single 100 kW panel), direct negotiated agreements with major pools typically secure reduced fees below standard 1 to 2 percent rates. At fleet scale above 50 PH/s, private pool arrangements become viable.

CapEx beyond miner acquisition: three phase electrical service with LP34 connectors ($10,000 to $30,000 per facility installation), hydro cooling loop with dry cooler infrastructure ($10,000 to $40,000 per rack depending on capacity), industrial rack hardware ($2,000 to $5,000 per rack), temperature monitoring systems. Annual OpEx per unit at 11,020W continuous: electricity at $7,725 at $0.08 per kWh, $6,759 at $0.07 per kWh, $3,862 at $0.04 per kWh industrial hosting rates. Water glycol coolant maintenance ($200 to $500 annually per unit at scale). Spare parts reserves (3 to 5 percent of acquisition annually). 3 year TCO per unit at $0.07 per kWh self hosted: approximately $32,379 hardware plus $20,277 electricity plus $1,500 maintenance equals $54,156 total. 3 year gross revenue at $0.07 per kWh profitability: $27,000 to $40,000.

Yes, verify before ordering. Standard 19 inch server racks come in multiple depth variants: 600 mm, 750 mm, 900 mm, 1000 mm, and 1200 mm commonly. The S23 Hyd 3U at 900 mm chassis depth requires minimum 1000 mm rack depth for proper cable management clearance, and 1200 mm rack depth provides comfortable cable and cooling management access. Most data center and dedicated mining facilities use 1000 mm or 1200 mm racks. Smaller 600 mm or 750 mm racks cannot accommodate this hardware. Check facility rack inventory and specifications before committing to large fleet orders.

Bitmain announced the S23 Hyd 3U in mid-2025 with batch shipping starting January 2026 per OneMiners and BT-Miners documentation. Subsequent batches continue through 2026 (January, March, April, September batches documented at OneMiners). MillionMiner inventory reflects current shipping batches with factory shipment within 5 to 10 business days for standard orders. Bulk deployments coordinate with Bitmain production schedules for delivery timelines. Pricing across distributor channels ranges $28,000 to $32,500 per unit with variation reflecting batch timing, warranty terms, and included services (DDP customs handling, hosting bundle availability).

Within Bitmain S23 generation: S23 Hydro 580TH standalone for lower per unit cost at same efficiency, S23 Air 318TH for air cooled deployment, S23 Immersion 442TH for tank deployment, S23E Hyd 2U 865TH for tier alternative. Within Bitmain S21 generation hydro: S21 XP Hydro 473TH and S21+ Hydro 395TH for single phase universal voltage alternatives when three phase infrastructure is unavailable, S21e XP Hydro 860TH for prior generation petahash tier. For operators diversifying across manufacturers at the petahash tier: Whatsminer M79S 1.35 PH/s represents MicroBT's equivalent high power hydro tier. Cross algorithm fleet diversification: Antminer KS7 for Kaspa, Antminer L11 for Litecoin and Dogecoin merged mining, IceRiver AE3 for Aleo. For operations building modular long lifespan infrastructure: Proto Rig at 819 TH/s provides Block's modular 10+ year chassis alternative to traditional sealed ASIC architecture. MillionMiner's ASIC hosting service accepts S23 Hyd 3U units at negotiated industrial electricity rates with full LP34 three phase and hydro cooling infrastructure included.

Get a Quote