Bitmain Antminer S23E Hyd 2U 865 TH/s SHA-256 Bitcoin Miner

Model: S23E Hyd 2U

865 TH/s 8650W SHA-256 10 J/TH

Select Availability

Quantity

Total Price

$11,699.00

Buying 10 or more? Get custom bulk pricing

Pay with: Bank Transfer | BTC | ETH | USDT

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Hashrate

865 TH/s

Power

8650 W

Efficiency

10.00 J/TH

Noise

50 dB

The Bitmain Antminer S23E Hyd 2U is the density-optimized mid tier of Bitmain's S23 hydro family: 865 TH/s of SHA-256 hashrate at 8,650W and 10 J/TH in a 2U rack chassis, also marketed as the Antminer S23E U2H. It sits between the standalone S23 Hydro 580TH and the S23 Hyd 3U 1,160TH, and it is the 2U miner to buy when rack space is the binding constraint: 21 units per standard 42U rack deliver 18.2 PH/s per cabinet at approximately 182 kW, the highest cabinet density in the S23 family. The unit draws 380 to 415V three-phase power, runs a closed-loop hydro system at a quiet 50 dB, and is built for professional data center deployment. MillionMiner supplies the Antminer S23E Hyd 2U with its integrated PSU, the Bitmain factory warranty, and free DDP worldwide delivery, all customs duties and import taxes paid.

Estimated Mining Returns

Based on current BTC price & network difficulty. Indicative only.

Period Daily Weekly Monthly
Income
$42.38 $296.66 $1,271.40
Electricity
-$10.38 -$72.66 -$311.40
Profit
$32.00 $224.00 $960.00

Using 0.050 $/kWh · Network difficulty as of today. Estimates only.

Adjust rate in the bar above

Updated daily. Last refresh: Aug 09, 2026. Estimates at $0.08/kWh.

At a Glance Live data · August 9, 2026
Best for

Top-efficiency pick — industrial-scale hydro deployments where efficiency and density beat upfront cost.

Your rate · $0.050/kWh
+$32.00 /day
ROI ~12 months
Hosted · $0.040/kWh
+$34.08 /day
ROI ~11 months
Avg US grid · $0.070/kWh
+$27.85 /day
ROI ~14 months
Home power · $0.120/kWh
+$17.47 /day
ROI ~22 months
Breakeven rate Profitable below $0.204/kWh
Efficiency rank #5 of 141 SHA-256 miners in our catalog (10 J/TH)
Availability In stock · ships in 5–7 days · DDP worldwide
Hosting compatibility ✓ Mississippi (hydro) ✓ Missouri (hydro)
Hashrate 865 TH/s
Power 8,650 W
Efficiency 10 J/TH
Noise 50 dB
Weight 17 kg
Cooling Hydro

Full Specifications

Hashrate 865 TH/s
Power Consumption 8650 W
Efficiency 10.00 J/TH
Algorithm SHA-256
Model S23E Hyd 2U
Release Year Apr 2026
Noise Level 50 dB
Dimensions 600 x 483 x 86mm
Weight 17 kg
Operating Temp 5 - 45 °C
Humidity 5 - 95 %
Cooling Type Hydro
Rack Format 2U

What's in the Box

S23E Hyd 2U
Power supply unit (PSU)
Power cables
Quick start guide

Contents may vary by batch. Exact items listed in order confirmation.

Quick Setup

1

Connect PSU to miner and plug into the outlet

2

Connect ethernet cable to your router or switch

3

Find miner IP via router admin or IP scanner tool

4

Open web interface, enter pool URL and wallet — start mining

Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.4
star star star star star

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso made-in-germany trustpilot
google-review

Get a Quote for the Bitmain Antminer S23E Hyd 2U 865 TH/s SHA-256 Bitcoin Miner

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Product Details

Bitmain Antminer S23E Hyd 2U Specifications, Rack Density, and Deployment Guide

The Bitmain Antminer S23E Hyd 2U produces 865 TH/s of SHA-256 hashrate at 8,650W wall draw and 10 J/TH efficiency in a 2U rack-mountable hydro-cooled chassis, with plus or minus 3 percent hashrate and 5 percent power tolerance per Bitmain documentation. Also marketed as the Antminer S23E U2H, it is the density-optimized mid tier of Bitmain's S23 hydro family. Positioning within the family. At 865 TH and 8,650W it produces 49 percent more hashrate per chassis than the base S23 Hydro (580 TH at 5,510W) at 57 percent more power. The per terahash trade is modest: 10 J/TH against 9.5 J/TH on the standalone and 3U variants, roughly 5 percent less efficient per terahash, a premium the form factor typically outweighs at scale. 2U rack height fits 21 units per standard 42U rack against 14 units for 3U hardware, delivering 18.2 PH/s per cabinet at approximately 182 kW, the highest cabinet density in the S23 family, which is why the S23E Hyd 2U is the 2U miner to buy when rack space is the binding constraint. The deployment matrix. The standalone S23 Hydro 580TH (9.5 J/TH, 410 x 170 x 209 mm, 13.5 kg) is the smallest unit at the lowest per-unit cost; the S23E Hyd 2U (10 J/TH, 600 x 483 x 86 mm, 17 kg net) captures maximum 2U density; the S23 Hyd 3U 1,160TH (9.5 J/TH, 900 x 486 x 132 mm, 21.5 kg, 1,000 mm plus rack depth) holds maximum per-chassis hashrate. Where rack space carries real infrastructure cost, typical of urban data centers, the 2U wins on per-rack-unit economics; where electricity efficiency is the primary constraint, the standalone and 3U win on per terahash efficiency. Competitive context. The MicroBT WhatsMiner M73S+ at 540 TH and 7,200W delivers 13.33 J/TH, 33 percent less efficient per terahash, and the Bitdeer SealMiner A3 Pro Hydro at 660 TH and 8,250W delivers 12.5 J/TH, 25 percent less efficient. Among current-generation hydro units at this tier the S23E Hyd 2U leads on per terahash efficiency and rack density, and neither MicroBT nor Bitdeer ships a 2U-format hydro unit at this combination. Deployment requirements. Power is 380 to 415V three-phase AC through an industrial three-phase connector, drawing approximately 13.1 amps per phase at 380V and 12.0 at 415V. Cooling is a closed loop through internal cold plates bonded to the hashboards, fed by an external CDU circulating water, deionized water, or water-glycol antifreeze, with heat rejection through a dry cooler or cooling tower sized at 8.5 kW plus per unit (about 29,500 BTU per hour). Mounting is standard 19-inch rack in a 2U slot with quick-disconnect hose fittings; operating range is 5 to 45 degrees Celsius at 5 to 95 percent humidity, with Ethernet 10/100M management and about 50 dB operating noise. Every Antminer S23E Hyd 2U ships from MillionMiner with its integrated PSU, cables, quick-start guide, the Bitmain factory warranty, and free DDP worldwide delivery covering customs clearance, duties, and taxes.

S23E Hyd 2U: The Density-Optimized Mid Tier of the S23 Hydro Family

Choosing within the S23 hydro family comes down to which constraint binds first. The S23E Hyd 2U at 865 TH/s and 10 J/TH exists for operations where rack space is that constraint: 21 units per 42U cabinet deliver 18.2 PH/s at approximately 182 kW, against 16.24 PH for 3U hardware and roughly 9.7 PH for standalone Hydro stacking, so the 2U captures the highest hashrate per cabinet in the family at acquisition pricing between the standalone and the 3U. Where electricity efficiency is the primary constraint instead, typical of rural facilities with cheap power, the standalone S23 Hydro 580TH and S23 Hyd 3U win at 9.5 J/TH. The 2U also slots naturally into existing Bitmain hydro fleets: it uses the same plumbing standards as S19 Pro+ Hyd, S21 Hydro, and S23 Hydro deployments, so an S23E refresh reuses the CDU, manifold, and heat-rejection infrastructure already in place. Profitability follows the same three variables as every SHA-256 miner: the Bitcoin price, network difficulty, and your electricity rate. At 8,650W, power cost is the dominant lever, and the 10 J/TH efficiency holds margin better than previous-generation hardware as difficulty rises; model your own rate on the live calculator before ordering. This is professional data center hardware: 380 to 415V three-phase service, hydro cooling infrastructure, and industrial heat rejection are requirements, not options, and single-phase deployment is not possible at this power level. For operators without their own hydro facility, ask about MillionMiner US hosting built for hydro hardware.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Antminer S23E Hyd 2U 865 TH/s Hydro Rack Miner

The density play of the S23 hydro family: 865 TH/s of SHA-256 at 8,650W and 10 J/TH in a 2U rack chassis, 600 x 483 x 86 mm at 17 kg net. It sits between the standalone S23 Hydro 580TH and the S23 Hyd 3U 1,160TH, packing 21 units and 18.2 PH/s into a 42U cabinet at roughly 182 kW. Power is 380 to 415V three-phase, cooling is a closed hydro loop at about 50 dB, and management is Ethernet 10/100M. The Antminer S23E Hyd 2U for sale at MillionMiner ships with its integrated PSU, the Bitmain factory warranty, and free DDP worldwide, and operators set on buying a rack mount Bitcoin miner at maximum cabinet density start here. For the current Antminer S23E Hyd 2U price, check the live listing and model your power rate on the calculator before you commit.

Maximum 2U Rack Density

21 units per standard 42U rack deliver 18.2 PH/s per cabinet at about 182 kW, 50 percent more units per cabinet than 3U hardware and the highest cabinet density in the S23 family.

Mid Tier of the Hydro Family

49 percent more hashrate per chassis than the base S23 Hydro at 57 percent more power, with acquisition cost between the standalone and the S23 Hyd 3U and the same 9.5 J/TH-class silicon behind it.

Built for Hydro Facilities

380 to 415V three-phase power, an external CDU with dry cooler heat rejection, and quick-disconnect 2U servicing. No hydro facility of your own? MillionMiner US hosting runs it for you.

FAQ

Frequently Asked Questions

865 TH/s SHA-256 at 8,650W and 10 J/TH efficiency on Bitmain's April 2026 generation S23E Hyd 2U chassis (also marketed as Antminer S23E U2H). ±3 percent hashrate and ±5 percent power tolerance per Bitmain documentation. The mid-tier density variant of the S23 hydro family, delivering 49 percent more hashrate per chassis than the base S23 Hydro (580 TH) and 75 percent of the S23 Hyd 3U hashrate (1,160 TH) in a more compact 2U rack format.

49 percent more hashrate at 57 percent more power, with slightly less efficient per terahash economics. Standalone S23 Hydro at 580 TH and 5,510W (9.5 J/TH) versus S23E Hyd 2U at 865 TH and 8,650W (10 J/TH): the 2U variant delivers 49 percent more hashrate per chassis, but at 5 percent less per terahash efficiency. The 2U variant wins on rack density (21 units per 42U cabinet versus standalone hydro stacking constrained by chassis depth) and on per-chassis hashrate consolidation. The standalone wins on per terahash efficiency and on per-unit acquisition cost. For density-constrained deployments, the 2U variant captures better total economics.

Lower acquisition cost per chassis with marginally less efficient per terahash economics, but higher rack density per cabinet. S23E Hyd 2U at 865 TH and 8,650W (10 J/TH) versus S23 Hyd 3U at 1,160 TH and 11,020W (9.5 J/TH): the 3U variant delivers 34 percent more hashrate per chassis at 27 percent more power consumption with 5 percent better per terahash efficiency. The 2U variant wins on rack density (21 units per 42U cabinet versus 14 for 3U, a 50 percent density advantage) and on lower acquisition cost per unit. The 3U variant wins on per-chassis hashrate and on per terahash efficiency. For maximum cabinet hashrate at fixed rack space, the 2U variant captures more total hashrate per 42U cabinet (18.2 PH versus 16.24 PH for 3U).

The S23E Hyd 2U wins decisively on per terahash efficiency. MicroBT WhatsMiner M73S+ at 540 TH and 7,200W delivers 13.33 J/TH (33 percent less efficient per terahash). Bitdeer SealMiner A3 Pro Hydro at 660 TH and 8,250W delivers 12.5 J/TH (25 percent less efficient). The S23E Hyd 2U also wins on absolute hashrate per chassis at this tier. Among current generation hydro flagships across all manufacturers, the S23E Hyd 2U leads on per terahash efficiency at this hashrate level and on rack density per 2U slot. No competing 2U format hydro Bitcoin miner from other manufacturers matches the S23E Hyd 2U's combination of efficiency, density, and per-chassis hashrate as of April 2026.

Yes across all realistic industrial deployment scenarios. At $0.08 per kWh: +$17.14 daily profit, +$514 monthly, +$6,256 annually. At $0.05 per kWh industrial rate: approximately +$23.37 daily, +$8,530 annually. At $0.04 per kWh: approximately +$25.45 daily, +$9,289 annually. At $0.07 per kWh per Mining Now February 2026 data: +$18.95 daily, +$6,917 annually. At $0.10 per kWh higher commercial rate: approximately +$12.99 daily profit, +$4,742 annually. Break even electricity rate at current Bitcoin network conditions is approximately $0.163 per kWh. ROI windows approximately 17 to 22 months at industrial hosting electricity rates depending on BTC price trajectory.

380 to 415V three-phase AC input via industrial three-phase connector. Standard industrial three-phase service required for deployment. At 380V three-phase draws approximately 13.1 amps per phase; at 415V approximately 12.0 amps per phase. Compatible with European and Asian three-phase commercial service, US 480V three-phase service (with appropriate transformer to 415V), and industrial mining facility service. Single-phase deployment is not supported and not possible at this power consumption level. The electrical infrastructure requirement makes the S23E Hyd 2U exclusively suitable for data center, industrial mining facility, or large commercial deployment with three-phase electrical service.

Closed-loop hydro cooling with internal cold plates bonded directly to hash board chips. External CDU (Coolant Distribution Unit) circulating water, deionized water, or water-glycol antifreeze. External heat rejection via dry cooler or cooling tower sized at 8.5+ kW per unit thermal load (29,500 BTU per hour). Standard 19-inch rack mounting in 2U slots with quick-disconnect hose fittings for serviceability. Coolant chemistry monitoring quarterly. Compatible with existing Bitmain hydro infrastructure (S19 Pro+ Hyd, S21 Hydro, S23 Hydro deployments) using the same plumbing standards. MillionMiner Equipment category includes Lianli radiators and CDU systems compatible with S23E Hyd 2U deployment.

50 dB hydro-cooled operation, comparable to a quiet office or normal conversation level. Substantially quieter than air-cooled equivalents at 75 dB. Hydro cooling eliminates the high-RPM exhaust fans that produce most ASIC noise. The remaining 50 dB noise comes from coolant pumps and minimal internal airflow components. Suitable for shared data center spaces and indoor mining facilities without specialized acoustic isolation requirements. Multi-unit deployment in standard data center configurations does not produce additive noise beyond comfortable industrial workspace levels.

600 x 483 x 86 mm in standard 2U rack format at 17 kg net weight per MillionMiner specification (some distributors including Mining Now list 19.1 kg, possibly accounting for full coolant or different measurement methodology). The 600 mm depth fits within standard 600 mm rack depth. Standard 19-inch rack mounting compatible with existing data center rack infrastructure. Single-person installation possible with appropriate lifting technique. Lighter than the S23 Hyd 3U (21.5 kg) and slightly heavier than the standalone S23 Hydro (13.5 kg).

5 to 45 degrees Celsius operating range per MillionMiner specification. The hydro variants typically require 20°C minimum inlet water temperature to prevent thermal cycling damage to chip cold plates. For external dry cooler deployment with controlled outlet temperatures, the S23E Hyd 2U follows the same Bitmain hydro family operating envelope: maximum ambient temperature approximately 30°C with 35°C coolant outlet, 40°C ambient with 45°C coolant outlet, 45°C ambient with 50°C coolant outlet. Storage temperature -20 to +70°C. Humidity tolerance 5 to 95 percent. The hydro cooling system tolerates wider ambient temperature range than air-cooled equivalents because heat rejection is decoupled from intake air temperature.

Bitcoin (BTC) is the primary target on the SHA-256 algorithm. Also mineable: Bitcoin Cash (BCH), Bitcoin SV (BSV), Fractal Bitcoin (FB), eCash (XEC), DigiByte (DGB) on SHA-256d, and any other SHA-256 derivative chain. Cannot mine Litecoin (Scrypt), Kaspa (KHeavyHash), Ethereum Classic (EtcHash), Aleo (zkSNARK), Alephium (Blake3), or any algorithm outside SHA-256. Most operators mine BTC directly at major pools (Foundry, AntPool, F2Pool, ViaBTC, Luxor, Braiins Pool) for maximum revenue stability.

Yes. The S23E Hyd 2U ships with an integrated PSU sized for the 8,650W rated load, along with power cables and quick start guide. Box contents per MillionMiner: Antminer S23E Hyd 2U unit, PSU, power cables, and quick start guide. Contents may vary by batch with exact items in order confirmation. The included PSU eliminates external power brick sourcing decisions and connector compatibility concerns. The PSU uses industrial three-phase connector standard for Bitmain hydro hardware.

Industrial data center deployment with hydro cooling infrastructure. Step one: verify three-phase 380-415V electrical circuit availability with appropriate breaker capacity (13 amps per phase at 380V). Step two: install in standard 19-inch rack with appropriate 2U slot dimensions. Step three: connect hydro cooling supply and return hoses via quick-disconnect fittings to facility CDU manifold. Step four: connect three-phase power cable to industrial connector. Step five: connect Ethernet cable to data center network switch. Step six: find miner IP through Bitmain IP Reporter or DHCP table, open Antminer web interface, login with default root/root credentials (change immediately for security), configure BTC pool URL and BTC wallet address. Step seven: verify hashrate stabilizes at approximately 865 TH/s within 15 to 20 minutes of startup.

Yes. MillionMiner hosting accepts S23E Hyd 2U units at managed hydro-cooled industrial facilities. At $0.05 per kWh industrial hosting rates: approximately +$23.37 daily profit per unit, +$8,530 annually. At $0.04 per kWh: approximately +$25.45 daily profit per unit, +$9,289 annually. Hosting eliminates facility CapEx, three-phase electrical infrastructure investment, hydro cooling system construction, industrial CDU and dry cooler installation, day-to-day operational overhead, and specialized hydro mining facility expertise requirements. For institutional and industrial buyers without existing hydro mining facility infrastructure, hosting through MillionMiner is the practical path to deploying the S23E Hyd 2U at scale. Contact MillionMiner for current hosting rates and facility availability.

360-day Bitmain factory warranty per BT-Miners distributor documentation (some sources cite 365 days). Some distributors offer extended 2-year coverage. Covers manufacturing defects and hardware failures under normal operating conditions. Tampering with warranty seal, use of incompatible PSU, exceeding rated voltage input, improper coolant chemistry, deployment outside rated operating temperature range, or physical damage from shipping voids coverage. Warranty claims processed through MillionMiner support with direct Bitmain channel escalation as needed.

Industrial hydro miner maintenance protocols. Quarterly coolant chemistry inspection (pH, conductivity, biological growth markers). Semi-annual coolant replacement or filtration based on system size and chemistry stability. Annual hash board inspection for chip-level performance variance. Continuous hashrate monitoring through Antminer web interface or BraiinsOS+ dashboard with alerting on temperature, hashrate, and power deviations. Quarterly hose fitting inspection for leakage or wear. The S23E Hyd 2U platform has limited field reliability data as of April 2026 (less than 1 month in market) but inherits the mature Bitmain hydro hardware design lineage from the S19 Pro+ Hyd through S21 Hydro and S23 Hydro generations with no expected reliability issues.

BraiinsOS+ supports the Antminer S23 series for autotuning optimization and is expected to support the S23E Hyd 2U variant from launch. The firmware provides per-chip performance data, advanced pool management, and comprehensive monitoring beyond Bitmain's stock firmware. Operators using BraiinsOS+ on S23 hardware typically achieve 2 to 5 percent additional efficiency improvements over stock firmware, equivalent to approximately $130 to $325 annually per S23E Hyd 2U unit at $0.08 per kWh electricity. Vnish firmware is another third-party option. Note that installing third-party firmware may affect manufacturer warranty coverage.

Choose the S23E Hyd 2U when rack density is the binding constraint. The 2U format delivers maximum hashrate per rack unit (18.2 PH per 42U cabinet versus 9.7 PH for standalone Hydro deployment or 16.24 PH for 3U) at acquisition pricing between the standalone and 3U variants. Choose the standalone S23 Hydro for lowest per-unit acquisition cost or for deployment in mixed S19/S21 hydro fleet integration. Choose the S23 Hyd 3U for maximum hashrate per chassis (1.16 PH single management endpoint) or when 3U rack slots are abundant. The 2U variant captures the rack density sweet spot for typical urban data center deployments where floor area carries real cost.

Buy the S23E Hyd 2U if you operate or are constructing an industrial data center with three-phase electrical service and hydro cooling infrastructure where rack density is the binding constraint, you want maximum hashrate per 42U cabinet across the S23 family, you are positioned for long term Bitcoin price growth, you have access to industrial hosting electricity rates for maximum profitability, you are running existing Bitmain S19 Pro+ Hyd or S21 Hydro fleets where S23 integration provides natural refresh, or you want a balance between per-unit acquisition cost and per-chassis hashrate. Consider the standalone S23 Hydro at 580 TH if you want lowest per-unit acquisition cost. Consider the S23 Hyd 3U at 1.16 PH/s if you operate at maximum density scale. Avoid the S23E Hyd 2U if you do not have data center scale hydro infrastructure or three-phase electrical service.

Within the S23 hydro family: standalone S23 Hydro at 580 TH for lower-cost per-unit deployment, S23 Hyd 3U at 1,160 TH for maximum per-chassis hashrate, S23 Immersion at 442 TH for immersion deployment infrastructure, S23 air-cooled at 318 TH for non-hydro deployment. For lower acquisition cost: S21 XP+ Hyd at 500 TH ($9,500), S21 XP HYDRO at 473 TH ($6,899), S21e XP Hydro at 860 TH ($11,649). Competing manufacturer hydro: MicroBT WhatsMiner M73S+ at 540 TH for higher hashrate alternative, Bitdeer SealMiner A3 Pro Hydro at 660 TH for Bitdeer ecosystem alternative. For complete data center infrastructure: MillionMiner Equipment category includes Lianli hydro radiators and CDU systems, Mining Containers for portable industrial deployment, Racks & Cabinets for proper rack mounting. For algorithm diversification beyond Bitcoin: Bitmain Antminer KS7 for Kaspa, Bitmain Antminer L11 for Litecoin and Dogecoin, Bitmain Antminer E11 for Ethereum Classic. For operators wanting hosting rather than self deployment, MillionMiner ASIC hosting services accept S23E Hyd 2U units. (1,072 characters)