MicroBT
Model: WhatsMiner M63S++
Temporarily Unavailable
This product is temporarily unavailable.
Notify Me
Be the first to know when this miner becomes available.
We'll notify you when it's available!
Genuine
Tested hardware
Worldwide
Global shipping
Support
Mining experts
Hashrate
478 TH/s
Power
10000 W
Efficiency
20.92 J/TH
Noise
50 dB
478 TH/s hydro cooled SHA-256 miner at 10,000W. 20.9 J/TH, 100 to 240V. MicroBT's highest hashrate M63S hydro rack unit. Ships from MillionMiner.
Based on current BTC price & network difficulty. Indicative only.
| Period | Daily | Weekly | Monthly |
|---|---|---|---|
|
Income
|
$23.45 | $164.15 | $703.50 |
|
Electricity
|
-$12.00 | -$84.00 | -$360.00 |
|
Profit
|
$11.45 | $80.15 | $343.50 |
Using 0.050 $/kWh · Network difficulty as of today. Estimates only.
Adjust rate in the bar aboveUpdated daily. Last refresh: Aug 09, 2026. Estimates at $0.08/kWh.
Industrial-scale hydro deployments where efficiency and density beat upfront cost.
Contents may vary by batch. Exact items listed in order confirmation.
Connect PSU to miner and plug into the outlet
Connect ethernet cable to your router or switch
Find miner IP via router admin or IP scanner tool
Open web interface, enter pool URL and wallet — start mining
Hydro-cooled miners require 380-415V three-phase power and a hydro cooling loop. Standard household outlets are not compatible. Contact our team for hosting options or setup guidance.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
The MicroBT Whatsminer M63S++ produces 478 TH/s at 10,000W in a 4U hydro cooled rack chassis. Top bin in the M63S series within MicroBT's M60 generation. Universal 100 to 240V input. 4U rack mount format at 483 x 663 x 86mm. Standard 19 inch rack compatible. 10 units per 42U rack at 4.78 PH/s and 100 kW. Water or water glycol closed loop cooling. Universal voltage on a 4U hydro rack miner is a specific advantage. The newer M73 hydro series (M70 generation) requires 380 to 480V three phase. Facilities with rack infrastructure and water cooling but only single phase power can deploy the M63S++ where the M73 cannot. 50 dB water cooled. 29.5 kg. Ethernet connectivity. 5 to 45 degrees Celsius. Bitcoin, Bitcoin Cash, all SHA 256. MicroBT firmware. The M63S+ (424 TH/s, 7,208W) and base M63 (334 TH/s, 6,646W) share the same 4U chassis at lower bins. Mix bins in the same rack and cooling loop. As M60 generation, the M63S++ is below the M73 series (M70 generation) in efficiency but offers the universal voltage advantage the newer generation dropped. Bitcoin mining with liquid cooling offers several operational advantages over air cooled alternatives: more consistent chip temperatures extend component life, elimination of fan noise reduces acoustic impact, and higher thermal headroom allows sustained peak performance without throttling. The infrastructure investment in cooling systems (water lines, pumps, heat exchangers or immersion tanks) is offset by longer hardware lifespan and higher uptime percentages across the fleet. For operators evaluating total cost of ownership across a 3 to 5 year deployment horizon, the reduced maintenance, lower failure rates, and sustained hashrate consistency of liquid cooled hardware can outperform air cooled alternatives despite higher initial infrastructure cost.
MicroBT M63S++. 478 TH/s hydro 4U at 10,000W on universal 100 to 240V. Top bin M63S. Standard rack mount. M60 generation. 10 units per 42U rack at 4.78 PH/s and 100 kW. Universal voltage on a 4U hydro rack miner. M73 series (M70 gen) requires 380V+. The M63S++ serves single phase rack facilities. 50 dB at 29.5 kg. 483 x 663 x 86mm. MicroBT firmware. M63S+ (424 TH/s) and M63 (334 TH/s) share the chassis. Ethernet. 5 to 45 degrees. Bitcoin, Bitcoin Cash, all SHA 256. Liquid cooling extends component life through more consistent thermal management. Reduced fan count means fewer mechanical failure points per unit. Sustained peak performance without thermal throttling. Higher total uptime percentage across fleet deployments compared to air cooled equivalents. Liquid cooled hardware requires infrastructure planning: water lines, pumps, heat exchangers or tanks. The investment pays back through higher uptime, longer component life, and sustained hashrate consistency. Budget for both hardware acquisition and cooling infrastructure in total cost of ownership calculations.
Our mining specialists can help you find the perfect miner for your setup and budget.
Moderate noise SHA-256 at 478 TH/s from MicroBT. 478 TH/s SHA 256 hydro 4U at 10,000W on 100 to 240V universal. Top bin M63S. 50 dB. 29.5 kg at 483 x 663 x 86mm. Standard 19 inch rack. 10 per rack at 4.78 PH/s. Single phase hydro rack. MicroBT firmware. Ethernet. Liquid cooling for extended component life, reduced maintenance, and sustained peak hashrate without thermal throttling. MicroBT manufacturer. Ethernet connectivity for pool configuration. Compare current pricing with competing models for best fleet value.
Nearly half a petahash from one unit. MicroBT's highest output rack mount hydro for maximum density deployments.
Standard single phase power support for global deployment flexibility in a hydro cooled rack unit.
Ships from MillionMiner with MicroBT warranty and free DDP delivery.
478 TH/s SHA-256 at 10000.00W. Bitcoin miner from MicroBT.
All SHA-256 cryptocurrencies: Bitcoin (BTC), Bitcoin Cash (BCH), BSV, eCash (XEC).
Yes. Free worldwide DDP shipping to 50+ countries. Genuine hardware with warranty.
Yes. Professional Bitcoin miner hosting from $0.055/kWh with 99.9% uptime and 24/7 monitoring.