No products found for ""
Bitmain
Model: Antrack V1 (24KW)
The Bitmain Antrack V1 is a complete hydro cooling rack that houses four Antminer Hydro miners and cools them on its own. It stands 2 metres tall on a footprint of 600 by 1000 mm and arrives as one closed cabinet.
Open… the mesh door and everything is already fitted: the water pump, the plate heat exchanger, 8 fans, the PDU and every hose and cable. Each of the 4 slots carries its own power cable and its own network cable, ready for a hydro miner.
You supply 3 phase power at 380 to 415 volts and one Ethernet cable. The pump circulates the coolant through the plate heat exchanger, the fans carry the heat outside, and your miners run. The heat stays yours: send it into underfloor heating, a greenhouse, aquaculture tanks or an industrial process.
Shipped by MillionMiner, DDP worldwide with duties paid, 12 months replacement parts warranty.
The Bitmain Antrack V1 is a complete hydro cooling rack that houses four Antminer Hydro miners and cools them on its own. It stands 2 metres tall on a footprint of 600 by 1000 mm and arrives as one closed cabinet.
Open… the mesh door and everything is already fitted: the water pump, the plate heat exchanger, 8 fans, the PDU and every hose and cable. Each of the 4 slots carries its own power cable and its own network cable, ready for a hydro miner.
You supply 3 phase power at 380 to 415 volts and one Ethernet cable. The pump circulates the coolant through the plate heat exchanger, the fans carry the heat outside, and your miners run. The heat stays yours: send it into underfloor heating, a greenhouse, aquaculture tanks or an industrial process.
Shipped by MillionMiner, DDP worldwide with duties paid, 12 months replacement parts warranty.
Get a quote for the Bitmain Antrack V1
Pricing, lead time, and hosting options. Personal advice from our sales team.
Get a quote for the Bitmain Antrack V1
Pricing, lead time, and hosting options. Personal advice from our sales team.
One rack and a 3 phase connection. The Antrack V1 arrives with the complete cooling loop inside it, so the work that usually falls to the operator has already been done at the factory.
A hydro deployment built from parts means sourcing a pump, a heat exchanger, manifolds, hoses, fittings, a PDU and fans from several suppliers, then assembling and pressure testing the loop on site. Bitmain put all of it into one 600 x 2000 x 1000 mm cabinet weighing 300 kg.
• Four slots: every slot takes an Antminer S19 Hyd, S21 Hyd or S23 Hyd and comes with its power cable and network cable already fitted.
• 24 kW maximum load: the rack carries four miners at full draw on 380 to 415 volts, 3 phase, up to… 80 amps.
• Closed cooling loop: water pump and plate heat exchanger are built in, so the coolant circulates the moment you switch on.
• 8 fans: the heat leaves the exchanger through the fan wall at the top of the cabinet.
• Usable heat: the exchanger hands the heat over in a form you can route onward instead of blowing it into the room.
How do I put the Antrack V1 into service? Slide four hydro miners into the slots, click the fitted power and network cables into place, connect the rack to 3 phase power and to Ethernet, and switch it on. The pump starts, the fans start, and the miners come up on the network.
Which Antminer models fit? The S19 Hyd, S21 Hyd and S23 Hyd series. These are the water cooled models, recognisable by the two coolant ports on the back instead of a fan on each end.
Where does a 24 kW rack belong? On a solid floor with a 3 phase supply and somewhere for the warm air to go. At 300 kg empty it is a fixture, not something you move between rooms.
Can I start with fewer than four miners? Yes. The rack runs with one, two or three slots filled and you add the rest later. The pump and the exchanger are sized for the full 24 kW, so a partly filled rack simply runs with headroom.
How does a 300 kg rack arrive? On a pallet, in its original packing, tested before it leaves us. Have a pallet truck and a level route from the kerb to the final position ready, because the cabinet is moved upright.
What if I have no site for it? Tell us the deployment country and what you want to run. We answer by phone, on WhatsApp or through the contact form, and we can host the rack for you in our own data centre instead.
Put it to work. The plate heat exchanger inside the Antrack V1 hands the heat over to a second water circuit, and that circuit is yours to use.
Four hydro miners at full load turn 24 kW of electricity into 24 kW of heat. In a standard air cooled room that heat is a problem you pay to remove. Behind a plate exchanger it is warm water at a useful temperature.
Our customers send it into underfloor heating, into greenhouses, into aquaculture tanks and into industrial process heat. The same kilowatt is earning twice: once as hashrate, once as… heat you would otherwise have bought.
How does that work in practice? The miners heat the coolant in their own sealed circuit. That circuit runs through the plate exchanger, where the heat crosses into your water without the two ever mixing. What leaves the exchanger is clean warm water on your side of the wall, at a temperature a heating circuit can use directly.
The fans are there for the days when you have nowhere to put the heat. They sit at the top of the cabinet and dump it to air, so the rack keeps running through the summer and you take the heat back in the autumn.
That is the difference between a rack with cooling bolted on and a rack designed around the exchanger. A standard rack gives you hot air in a room you then have to ventilate. This one hands you a water circuit.
Tell us what your site can absorb, the building, the process, the hectares of greenhouse, and we will work it through with you before you order.
Our mining specialists can help you find the perfect miner for your setup and budget.
• The Antrack V1 cabinet, 600 x 2000 x 1000 mm, 300 kg, with the mesh door, the 4 rack slots and the fan wall
• The complete cooling loop already installed: water pump, plate heat exchanger, 8 fans, all hoses and all fittings
• The PDU with the power cable and the network cable fitted in every one of the 4 slots
• Documentation, factory tested and in its original packing
Shipped by MillionMiner, DDP worldwide with duties paid, 12 months replacement parts warranty. The miners themselves are ordered separately, so you can match the S19 Hyd, S21 Hyd or S23 Hyd to your own power budget.
The Antrack V1 sits in our equipment range, next to the containers, radiators and cabinets that carry the same hydro miners.
See all equipmentPut your own power rate into the comparison and see the daily figure for the S19 Hyd, S21 Hyd and S23 Hyd side by side.
Open the comparisonWe run the rack in our own data centre and you keep the payout. Power, cooling and monitoring are handled for you.
See hostingThere are no reviews for this product yet.
Be the first one to review it.
Did you purchase this product?
Write a review about this miner and help other buyers decide.
It is a mining rack with the hydro cooling built in. Four Antminer Hydro miners slide into it, and the water pump, plate heat exchanger, 8 fans and PDU that would normally be separate purchases are already inside the cabinet.
The current price stands in the buy box at the top of this page. It is a DDP price: duties are paid and nothing is added on delivery.
The Antminer S19 Hyd, S21 Hyd and S23 Hyd series. These are the water cooled models with two coolant ports on the back.
Four. The cabinet has 4 rack slots, and every slot arrives with its own power cable and network cable already fitted.
Up to 24 kW in total, which is four hydro miners at full draw. The supply is 3 phase at 380 to 415 volts with up to 80 amps.
A 3 phase connection at 380 to 415 volts, 50 or 60 Hz, rated for up to 80 amps. That is an industrial supply, the same class a workshop or a farm building has.
Yes. Pump, plate heat exchanger, fans, hoses and fittings are installed and connected at the factory. You add power, network and the miners.
The water pump, the plate heat exchanger, 8 cooling fans, the PDU for power distribution, and every hose and cable the loop needs.
600 mm wide, 2000 mm high and 1000 mm deep. It is about as tall as a door and needs clear space in front for the mesh door to swing open.
300 kg empty. Plan the delivery to the floor it will stand on, because it is a fixture once it is in place.
Through one Ethernet cable. The rack carries an RJ45 port at 10/100M, and each slot has its own network cable waiting for a miner.
Yes, and that is the point of the plate heat exchanger. Customers run it into underfloor heating, greenhouses, aquaculture tanks and industrial process heat.
Close to everything they draw. At 24 kW of electrical load you have roughly 24 kW of heat leaving the exchanger.
The rack is sold on its own, so you can match the S19 Hyd, S21 Hyd or S23 Hyd to your own power budget. Ask us and we will quote the rack and the miners together.
We list the V1 here. If you are looking for another Bitmain rack or a different capacity, send us the model and we will tell you what we can source.
The rack has no say in that. The pool address is entered in each miner, so four miners in one Antrack can point at four different pools if you want.
Yes. The gallery at the top of this page shows the cabinet from the front and from the side, with the door open and the manifolds, the pump and the PDU in view.
Yes, DDP worldwide with duties paid. Tell us the destination country and we will confirm the route before you order.
12 months replacement parts warranty through MillionMiner. If something in the loop fails inside that period, we send the part.
Please ask your tax advisor, as we are not permitted to give advice on that.