Out of Stock

Lianli

Lianli Hydro Cooling Radiator (12 KW)

Model: Hydro Radiator 12KW

New

Lianli Hydro Cooling Radiator (12 KW) is 12KW external water cooling radiator from Lianli, the only model in the lineup rated for factory hydro ASIC miners. Supports Bitmain Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro, S23 Hyd 3U, and Whatsminer M33S+, M53, M53S, M63, M63S series. Also handles two converted air cooled miners simultaneously below 25 degrees ambient. Intelligent temperature control automatically maintains inlet water between 20 to 40 degrees Celsius, preventing cold startup failures on S23 Hydro units. Adjustable 500 to 6,000 RPM fans. Integrated pump with manually adjustable pressure reducing valve. Built in 220V power, one button startup. Universal 90 to 305V. 10mm and 12mm pipe kit variants. ~8L coolant capacity. CE certified. 1 year warranty.

Temporarily Unavailable

This product is temporarily unavailable.

Notify Me

Be the first to know when this miner becomes available.

Get a Quote

Interested in this miner? Contact us for availability and pricing.

Get a Quote

Genuine

Tested hardware

Worldwide

Global shipping

Support

Mining experts

Full Specifications

Model Hydro Radiator 12KW
Voltage 90-305V
Capacity 12KW
Adjustable Fan's speed 500- 4500rpm
CE Certification Support Antminer, Whatsminer, Avalon, Ipollo, Innosilicon
Heating 30-50 degree

Request a Bitcoin Miner Hosting Quote

Free quote, reply in 24h. No sales call.

4.7
star star star star star

4.7 / 5 on Trustpilot

Verified customer reviews

30,000+ miners delivered

Shipped worldwide since 2020

1,200+ customers globally

Trusted in 50+ countries

iso made-in-germany trustpilot
google-review

Get a Quote for the Lianli Hydro Cooling Radiator (12 KW)

Pricing, lead time, and hosting options. Personal advice from our sales team.

Reply within 24h via email, WhatsApp, or call.

Product Details

Lianli 12KW Hydro Cooling Radiator for Antminer S21 Hydro, S23 Hydro, and Whatsminer M53/M63 Factory Hydro Miners: Specifications and Deployment Guide


The Lianli 12KW is the flagship of the three tier radiator lineup and the only model rated for factory hydro ASIC miners. Per Vipera (certified reseller), the 4.5KW and 8KW models are strictly for waterblock retrofit conversions of air cooled ASICs. Any operator running a factory hydro miner from Bitmain or MicroBT needs this 12KW model or a more expensive industrial cabinet solution.
Confirmed compatible hardware spans both major hydro manufacturers. Bitmain: Antminer S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro 319TH through 395TH variants, S23 Hydro 580TH, S23 Hyd 3U 1.16 PH/s. MicroBT: Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. The 12KW also handles two converted air cooled miners simultaneously when ambient temperature stays below 25 degrees Celsius, making it a dual purpose investment for operators running mixed fleets.
Intelligent temperature control is the defining upgrade over the smaller models. The system automatically adjusts fan speed and pump output to maintain inlet water temperature between 20 to 40 degrees Celsius regardless of ambient conditions. This solves a real operational problem: the Bitmain S23 Hydro cannot start when inlet water drops below 20 degrees Celsius. In cold climates, unheated warehouses, or winter months, that startup interlock shuts down mining until water warms up. The 12KW's auto control maintains minimum inlet temperature continuously, preventing downtime without manual monitoring.
Fan speed range runs 500 to 6,000 RPM, a higher ceiling than the 4,500 RPM maximum on the 4.5KW and 8KW models, reflecting the greater thermal load these factory hydro miners produce. Integrated pump with manually adjustable pressure reducing valve provides flow control without external components. Built in 220V power supply enables one button startup with no external PSU required.
Two pipe kit variants are available: 10mm kit for miners with 10mm manifold inlet/outlet, and 12mm kit for 12mm manifold miners. Verify your specific miner's manifold size before ordering. Approximately 8L pure water or coolant capacity. Stainless steel fittings with 3M wall thickness. Lianli recommends fully inserting the inlet pipe into the pump to minimize bubble generation.
Compared to traditional mining cabinets that cost $5,000 to $15,000+ for equivalent cooling capacity, the Lianli 12KW provides a cost efficient alternative for operators running 1 to 2 hydro miners. Cabinets make economic sense at 6+ miner deployments; the Lianli radiator wins at smaller scales.
Universal 90 to 305V input. CE certified. 1 year manufacturer replacement parts warranty. Currently out of stock at MillionMiner. Free DDP delivery when available.

Lianli 12KW Hydro Radiator: The Only Model Rated for S21 Hydro, S23 Hydro, and Factory Hydro ASICs

The 4.5KW and 8KW handle converted air cooled miners. The 12KW is the tier that handles factory hydro ASICs, which is what most buyers searching for hydro cooling radiators actually need.
Confirmed compatible factory hydro miners: Bitmain Antminer S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro, S23 Hydro, S23 Hyd 3U, and Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. Also handles two converted air cooled miners simultaneously when ambient stays below 25 degrees Celsius.
The intelligent temperature control is the standout feature versus the smaller models. It automatically adjusts fan speed and pump output to maintain inlet water temperature between 20 to 40 degrees Celsius year round. This directly solves the S23 Hydro cold startup problem: that miner cannot boot when inlet water drops below 20 degrees. In cold climates or winter months, the 12KW's auto control prevents startup failures without manual intervention.
Adjustable 500 to 6,000 RPM (higher ceiling than the 4,500 RPM on smaller models). Integrated pump with manually adjustable pressure reducing valve. ~8L coolant capacity. 10mm and 12mm pipe kit variants match different miner manifold sizes. Universal 90 to 305V. CE certified. 1 year warranty.

Need Help Choosing?

Our mining specialists can help you find the perfect miner for your setup and budget.

Lianli 12KW Hydro Cooling Radiator for Factory Hydro ASIC Miners

The only Lianli radiator rated for factory hydro miners. 12KW thermal capacity supports Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro, Whatsminer M33S+, M53, M53S, M63, M63S, and two converted air cooled miners below 25 degrees ambient. Intelligent temperature control keeps inlet water between 20 to 40 degrees Celsius automatically, solving the S23 Hydro cold startup problem. Adjustable 500 to 6,000 RPM. Integrated pump with pressure reducing valve. Built in 220V power, one button startup. Universal 90 to 305V. 10mm and 12mm pipe kit options. CE certified. 1 year warranty.

The Only Model for Factory Hydro ASICs

12KW capacity for S21 Hydro, S23 Hydro, Whatsminer M53/M63 series. The 4.5KW and 8KW cannot cool factory hydro miners.

Intelligent 20 to 40 Degree Inlet Control

Auto maintains inlet water temperature year round. Solves S23 Hydro cold startup failures in winter without manual monitoring.

500 to 6,000 RPM, Integrated Pump

Higher fan ceiling than smaller models. Built in pump with pressure valve. One button 220V startup. 10mm and 12mm pipe kits.

FAQ

Frequently Asked Questions

Bitmain: S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro (all variants), S23 Hydro 580TH, S23 Hyd 3U 1.16 PH/s. MicroBT: Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. This is the only Lianli radiator rated for these factory hydro units.

Factory hydro miners draw 5,000W+ thermal load with higher coolant flow requirements than converted air cooled miners. The 4.5KW (3,500W max) and 8KW (7,000W max) lack the thermal capacity, pump flow rate, and pressure management factory hydro ASICs require. Using undersized radiators causes thermal throttling, hashrate drops, and potential hardware damage.

Automatic fan and pump adjustment to maintain inlet water between 20 to 40 degrees Celsius year round. Critical for S23 Hydro owners: that miner cannot boot when inlet water drops below 20 degrees. In cold climates or unheated facilities, the 12KW keeps inlet temperature above the startup threshold continuously without manual monitoring.

Yes, under conditions. Per Zeus Mining: supports two factory hydro miners OR two converted air cooled miners when ambient temperature stays below 25 degrees Celsius. Above 25 degrees ambient, capacity reduces and single miner operation is recommended for reliable thermal management.

Refers to the miner's manifold inlet/outlet diameter. Some hydro miners use 10mm ports, others use 12mm. Order the kit matching your specific miner's port size. Zeus Mining lists both variants. Check your miner's documentation or measure the port before purchasing.

Mining cabinets cost $5,000 to $15,000+ for equivalent cooling and accommodate 6+ miners in an integrated enclosure. The Lianli 12KW costs a fraction of that for 1 to 2 miner setups. Cabinets win on scale; the Lianli radiator wins on cost efficiency for small deployments. Operators running 1 to 4 hydro miners typically find the Lianli approach more economical.

Universal 90 to 305V via C14 socket. Built in 220V power supply enables one button startup. No external power supply or voltage conversion needed. Works on all standard residential and commercial electrical service worldwide.

Approximately 8L pure water or coolant. Use distilled water for mild climates. Water glycol mixture for cold climates where standstill freezing is possible. Avoid tap water.

500 to 6,000 RPM, higher than the 4,500 RPM ceiling on the 4.5KW and 8KW models. The higher range handles the greater thermal load factory hydro miners produce at sustained full power operation.

Yes, and this is one of its strongest use cases. Factory hydro miners are quieter than air cooled (50 dB chassis versus 75 dB), but still need external heat rejection. The 12KW radiator placed in a garage, basement, or near a window provides that heat rejection at home scale without a $10,000+ cabinet investment.

Get a Quote