Lianli
Model: Hydro Radiator 12KW
Lianli Hydro Cooling Radiator (12 KW) is 12KW external water cooling radiator from Lianli, the only model in the lineup rated for factory hydro ASIC miners. Supports Bitmain Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro, S23 Hyd 3U, and Whatsminer M33S+, M53, M53S, M63, M63S series. Also handles two converted air cooled miners simultaneously below 25 degrees ambient. Intelligent temperature control automatically maintains inlet water between 20 to 40 degrees Celsius, preventing cold startup failures on S23 Hydro units. Adjustable 500 to 6,000 RPM fans. Integrated pump with manually adjustable pressure reducing valve. Built in 220V power, one button startup. Universal 90 to 305V. 10mm and 12mm pipe kit variants. ~8L coolant capacity. CE certified. 1 year warranty.
Temporarily Unavailable
This product is temporarily unavailable.
Notify Me
Be the first to know when this miner becomes available.
We'll notify you when it's available!
Genuine
Tested hardware
Worldwide
Global shipping
Support
Mining experts
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Our mining specialists can help you find the perfect miner for your setup and budget.
12KW capacity for S21 Hydro, S23 Hydro, Whatsminer M53/M63 series. The 4.5KW and 8KW cannot cool factory hydro miners.
Auto maintains inlet water temperature year round. Solves S23 Hydro cold startup failures in winter without manual monitoring.
Higher fan ceiling than smaller models. Built in pump with pressure valve. One button 220V startup. 10mm and 12mm pipe kits.
Bitmain: S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro (all variants), S23 Hydro 580TH, S23 Hyd 3U 1.16 PH/s. MicroBT: Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. This is the only Lianli radiator rated for these factory hydro units.
Factory hydro miners draw 5,000W+ thermal load with higher coolant flow requirements than converted air cooled miners. The 4.5KW (3,500W max) and 8KW (7,000W max) lack the thermal capacity, pump flow rate, and pressure management factory hydro ASICs require. Using undersized radiators causes thermal throttling, hashrate drops, and potential hardware damage.
Automatic fan and pump adjustment to maintain inlet water between 20 to 40 degrees Celsius year round. Critical for S23 Hydro owners: that miner cannot boot when inlet water drops below 20 degrees. In cold climates or unheated facilities, the 12KW keeps inlet temperature above the startup threshold continuously without manual monitoring.
Yes, under conditions. Per Zeus Mining: supports two factory hydro miners OR two converted air cooled miners when ambient temperature stays below 25 degrees Celsius. Above 25 degrees ambient, capacity reduces and single miner operation is recommended for reliable thermal management.
Refers to the miner's manifold inlet/outlet diameter. Some hydro miners use 10mm ports, others use 12mm. Order the kit matching your specific miner's port size. Zeus Mining lists both variants. Check your miner's documentation or measure the port before purchasing.
Mining cabinets cost $5,000 to $15,000+ for equivalent cooling and accommodate 6+ miners in an integrated enclosure. The Lianli 12KW costs a fraction of that for 1 to 2 miner setups. Cabinets win on scale; the Lianli radiator wins on cost efficiency for small deployments. Operators running 1 to 4 hydro miners typically find the Lianli approach more economical.
Universal 90 to 305V via C14 socket. Built in 220V power supply enables one button startup. No external power supply or voltage conversion needed. Works on all standard residential and commercial electrical service worldwide.
Approximately 8L pure water or coolant. Use distilled water for mild climates. Water glycol mixture for cold climates where standstill freezing is possible. Avoid tap water.
500 to 6,000 RPM, higher than the 4,500 RPM ceiling on the 4.5KW and 8KW models. The higher range handles the greater thermal load factory hydro miners produce at sustained full power operation.
Yes, and this is one of its strongest use cases. Factory hydro miners are quieter than air cooled (50 dB chassis versus 75 dB), but still need external heat rejection. The 12KW radiator placed in a garage, basement, or near a window provides that heat rejection at home scale without a $10,000+ cabinet investment.