Model: Hydro Cooling Rack (182KW)
Professional hydro cooling cabinet housing 28 factory hydro ASIC miners across 7 layers of 4 units each. 182KW total power capacity via dual PDU systems delivering 1,200A combined current. Dedicated hot water out and… cold water in valves per miner with minimum 8 liters per minute flow rate. 346 to 425V three phase input (380 to 480V per some distributor documentation). Compatible with Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro and Whatsminer M33S+, M53, M53S, M63 series. Factory hydro miners only; cannot accommodate waterblock converted units. Requires external CDU and dry cooler or water tower (verify inclusion with MillionMiner). PLC remote monitoring via internet and APP. 100 x 80 x 230 cm. 360 kg cabinet weight. CE certified.
Request Your Custom Rack Quote
Tell us your configuration and where you need delivery. Our specialist replies within 24 hours via email, WhatsApp, or call.
Why this product needs a custom quote
Racks and cabinets are configured to order and shipped as bulky freight. Final pricing depends on your delivery destination, quantity, and on-site requirements. Submit the form below and our specialist will reply within 24 hours with a complete quote including hardware, shipping, customs, and DDP delivery to your site.
Thanks! Our specialist will reply within 24 hours with your custom quote.
How your rack order works
Submit form
Tell us delivery country & configuration
Get your quote
Complete pricing within 24 hours
Review with specialist
Discuss specs, customise setup
DDP delivery
Shipped to your site
Genuine
Tested hardware
Worldwide
Global shipping
Support
Mining experts
Professional hydro cooling cabinet housing 28 factory hydro ASIC miners across 7 layers of 4 units each. 182KW total power capacity via dual PDU systems delivering 1,200A combined current. Dedicated hot water out and… cold water in valves per miner with minimum 8 liters per minute flow rate. 346 to 425V three phase input (380 to 480V per some distributor documentation). Compatible with Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro and Whatsminer M33S+, M53, M53S, M63 series. Factory hydro miners only; cannot accommodate waterblock converted units. Requires external CDU and dry cooler or water tower (verify inclusion with MillionMiner). PLC remote monitoring via internet and APP. 100 x 80 x 230 cm. 360 kg cabinet weight. CE certified.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
The Lianli 28-miner hydro cooling cabinet is purpose built for mining operations scaling beyond standalone radiators into facility grade infrastructure. Housing 28 factory hydro ASIC miners across 7 layers with 4 units per row, this cabinet centralizes power distribution, coolant management, and miner deployment into a single 100 x 80 x 230 cm rack weighing 360 kg. Dual PDU systems deliver 182KW total power capacity at 1,200A combined current through individual aviation plugs rated for up to 6.5KW per miner. Input voltage ranges 346 to 425V three phase (some distributor documentation lists 380 to 480V at 50/60Hz). Each miner slot features dedicated hot water out and cold water in valves… with minimum 8 liters per minute coolant flow rate per unit. Individual valve isolation allows servicing or swapping any single miner without shutting down coolant flow to the remaining 27. Critical limitation: the 28-unit cabinet accommodates factory hydro miners only. Per Lianli's product documentation, this configuration cannot house waterblock converted air cooled units. Operators running converted hardware should look at the 24-unit cabinet, which handles both factory and modified hydro miners. Compatible factory hydro hardware: Bitmain Antminer S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro, S23 Hydro, S23 Hyd 3U, and Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. The cabinet is not a standalone solution. It requires external CDU (Cooling Distribution Unit) and heat rejection infrastructure. Two configurations are documented across distributors: cabinet + CDU + 200KW dry cooler (1,200 kg total system weight, 11 CBM shipping volume) or cabinet + CDU + 30T closed water tower (1,500 kg total, 14 CBM). A single CDU connects up to 10 cabinets for clustered management at facility scale. Verify with MillionMiner whether the listing covers the cabinet only or the full system including CDU and heat rejection. PLC remote monitoring provides internet and APP based access to system parameters and operational status. Operators can monitor coolant temperatures, flow rates, power distribution, and individual miner status without physical facility access. Parameter settings adjust remotely for seasonal optimization or emergency response. Compared to running 28 individual Lianli 12KW radiators (which would cost more, take dramatically more floor space, and create 28 separate coolant loops to maintain), the cabinet centralizes everything into one managed system. The tradeoff is higher upfront infrastructure investment and the three phase industrial electrical requirement that limits deployment to professional mining facilities.
The 28-miner cabinet is Lianli's flagship rack for mining operations that have outgrown standalone radiators. Where the 12KW radiator handles 1 to 2 hydro miners, this cabinet houses 28 across 7 layers with 4 miners per row, supported by dual PDU systems delivering 182KW total power at 1,200A combined current. Every miner slot has dedicated hot water out and cold water in valves maintaining minimum 8 liters per minute coolant flow. That per miner isolation means individual units can be serviced or swapped without disrupting the remaining 27.… Each aviation plug supports up to 6.5KW per miner. Important: factory hydro miners only. The 28-unit configuration cannot accommodate waterblock converted air cooled units (the 24-unit cabinet does). Compatible hardware: Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro, Whatsminer M33S+, M53, M53S, M63 series. Requires external CDU (Cooling Distribution Unit) and heat rejection infrastructure (200KW dry cooler or 30T closed water tower). A single CDU connects up to 10 cabinets for clustered fleet management. PLC remote monitoring via internet and APP provides system parameter control and status monitoring without physical facility access. 346 to 425V three phase. 100 x 80 x 230 cm at 360 kg.
Our mining specialists can help you find the perfect miner for your setup and budget.
Industrial hydro cooling cabinet for 28 factory hydro miners across 7 layers of 4 units. 182KW total power via dual PDU at 1,200A combined. Dedicated hot/cold water valves per miner at 8L/min minimum flow. Compatible with Antminer S19/S21/S23 Hydro and Whatsminer M33S+/M53/M63 series. Factory hydro only, not for waterblock conversions. Requires external CDU and heat rejection (dry cooler or water tower). PLC remote monitoring via internet/APP. 346 to 425V three phase. 100 x 80 x 230 cm at 360 kg. Aviation plug per miner supports up to 6.5KW.
7 layers, 4 miners per row. Dedicated hot/cold water valves per miner. Individual isolation for service without fleet disruption.
Each aviation plug supports 6.5KW. 346 to 425V three phase input. Built for S21 Hydro, S23 Hydro, Whatsminer M53/M63 class hardware.
Monitor coolant, power, and miner status remotely. Adjust system parameters without facility access. One CDU connects up to 10 cabinets.
Factory hydro miners only. Antminer S19 Hydro, S19 Pro Hydro, S21 Hydro, S21 XP Hydro, S21+ Hydro, S23 Hydro, S23 Hyd 3U, Whatsminer M33S+, M33S++, M53, M53S, M63, M63S. Cannot accommodate waterblock converted air cooled miners. The 24-unit Lianli cabinet handles both factory and converted; this 28-unit model is factory only.
Varies by configuration. Distributors document two system packages: cabinet + CDU + 200KW dry cooler (1,200 kg total, 11 CBM) or cabinet + CDU + 30T closed water tower (1,500 kg total, 14 CBM). Confirm with MillionMiner sales whether the listing covers the cabinet alone or the complete system.
346 to 425V three phase input (380 to 480V per some distributor documentation). Professional mining facility or industrial site with three phase electrical service rated for 182KW continuous load. This is not deployable on residential or standard commercial electrical service.
7 layers with 4 miners per row, totaling 28 slots. Each slot has dedicated hot water out and cold water in valves. Each aviation plug delivers up to 6.5KW. Dual PDU systems provide 1,200A total current capacity.
8 liters per minute per miner. Individual valve isolation means servicing one unit does not interrupt coolant flow to the other 27. This per miner isolation is a significant operational advantage over shared manifold designs.
: Internet and APP based remote access to system parameters and operational status. Monitor coolant temperatures, flow rates, power distribution, and individual miner status without being at the facility. Adjust parameter settings remotely for seasonal optimization or emergency response. One CDU connects up to 10 cabinets for clustered management.
Physical slot dimensions and coolant connection specifications are designed exclusively for factory hydro miner form factors. Waterblock converted air cooled miners have different chassis dimensions and connection geometries. The 24-unit Lianli cabinet accommodates both factory and converted units with more flexible slot sizing.
The cabinet centralizes power distribution, coolant management, miner deployment, and monitoring into one system. 28 separate radiators would cost more in aggregate, occupy dramatically more floor space, require 28 individual coolant loops to maintain, and offer no centralized monitoring. The cabinet is the correct choice at 10+ miner scale.
Yes. The cabinet accommodates up to 28 but can operate with fewer units. Empty slots simply have their water valves closed. Operators commonly deploy 10 to 15 miners initially and fill remaining slots as hardware arrives or capital becomes available. The dual PDU and cooling systems operate proportionally to actual load.
Coolant quality testing monthly. CDU pump and flow inspection quarterly. Individual miner valve inspection for leaks. Dry cooler or water tower maintenance per manufacturer schedule. PDU connection integrity checks. PLC monitoring system catches most issues remotely before they require physical intervention.