Lianli
Model: Hydro Cooling Rack (85KW)
Request Your Custom Rack Quote
Tell us your configuration and where you need delivery. Our specialist replies within 24 hours via email, WhatsApp, or call.
Why this product needs a custom quote
Racks and cabinets are configured to order and shipped as bulky freight. Final pricing depends on your delivery destination, quantity, and on-site requirements. Submit the form below and our specialist will reply within 24 hours with a complete quote including hardware, shipping, customs, and DDP delivery to your site.
Thanks! Our specialist will reply within 24 hours with your custom quote.
How your rack order works
Submit form
Tell us delivery country & configuration
Get your quote
Complete pricing within 24 hours
Review with specialist
Discuss specs, customise setup
DDP delivery
Shipped to your site
Genuine
Tested hardware
Worldwide
Global shipping
Support
Mining experts
Compact 85KW hydro cooling rack housing 5 factory hydro ASIC miners. Entry tier of Lianli's cabinet lineup for operators scaling beyond standalone radiators but not yet at the 28-miner industrial cabinet level. 380V three phase power with 225A main switch and triple 100A AC contactors. 16-bit PDU with 16A x 3 distribution. DN40 main water pipe and DN8 single layer cooling lines. 5 integrated protection functions. Monitoring system with online upgrade support. Requires external CDU and dry cooler. 65 x 110 x 235 cm. Compatible with Antminer and Whatsminer hydro series miners.
Deployments of 5 miners or smaller, using hydro-cooled hardware at 85 kW per rack.
Pricing, lead time, and hosting options. Personal advice from our sales team.
Pricing, lead time, and hosting options. Personal advice from our sales team.
The Lianli 85KW hydro cooling rack is the entry tier of Lianli's cabinet lineup, positioned for operators running 3 to 5 factory hydro miners who need more organization than standalone radiators but less infrastructure than the 28-miner industrial cabinet. Five miners in a single managed rack with centralized power, water, monitoring, and protection in a 65 x 110 x 235 cm footprint. The practical scale question this rack answers: when do you stop using individual 12KW radiators and switch to a cabinet? At 1 to 2 hydro miners, standalone radiators make economic sense. At 3 to 5 miners, managing 3 to 5 separate radiators with individual coolant loops, power cables, and monitoring becomes operationally messy. The 85KW rack consolidates everything into one managed system. At 6+ miners, the 28-miner cabinet or larger infrastructure takes over. Power distribution uses industrial grade components throughout. 380V three phase input with 225A main switch and three 100A AC contactors handles the combined load of 5 hydro miners drawing up to 85KW total. Main cable runs 35mm squared copper with 16mm squared branch cables to individual miner positions. The 16-bit PDU provides 16A x 3 distribution across miner slots. These specifications support current gen hydro miners like the S21 XP Hydro (5,676W), S23 Hydro (5,510W), and Whatsminer M53/M63 class hardware without electrical bottlenecks. Water circulation architecture uses DN40 main pipe (40mm diameter) feeding DN8 single layer cooling lines (8mm diameter) per miner slot. The DN40 main provides sufficient flow capacity for all 5 miners simultaneously. Individual DN8 lines to each miner ensure adequate per unit coolant delivery for stable chip temperatures. Five integrated protection functions provide operational safety. Based on Lianli's standard cabinet architecture across their product line, these likely include over temperature protection, over pressure protection, leak detection, over current protection, and flow rate monitoring. The monitoring system supports online upgrades, meaning firmware and software improvements deploy over the network as Lianli releases updates. Like every Lianli cabinet, this rack requires external CDU and heat rejection infrastructure. The CDU manages coolant circulation, temperature control, and pressure regulation. Heat rejection happens through a dry cooler (outdoor air to coolant heat exchange) or water tower. The rack itself handles power distribution and miner mounting. Confirm with MillionMiner sales whether the listing covers the rack only or includes CDU and dry cooler as a complete system. Compatible with factory hydro miners from Bitmain (S19 Hydro series, S21 Hydro, S21 XP Hydro, S23 Hydro) and MicroBT (Whatsminer M33S+, M53, M53S, M63 series). Confirm slot dimensions for S23 Hyd 3U compatibility given its larger chassis format. Currently out of stock at MillionMiner. Free DDP delivery when available.
The 85KW rack fills the gap between running a few standalone 12KW radiators and committing to the 182KW 28-miner industrial cabinet. Five hydro miners in a single managed rack with centralized power distribution, water circulation, monitoring, and protection systems. Power infrastructure is serious for its size: 380V three phase with a 225A main switch, three 100A AC contactors, 35mm squared main cable and 16mm squared branch cable. The 16-bit PDU provides 16A x 3 distribution. These are not consumer grade electrical components. This is industrial mining rack infrastructure sized for 5 miners instead of 28. Water circulation runs through DN40 main pipe splitting to DN8 single layer lines per miner. Five integrated protection functions cover operational safety (likely over temperature, over pressure, leak detection, over current, and flow monitoring based on Lianli's standard cabinet architecture). Monitoring system supports online upgrades for firmware and parameter improvements over time. Like the larger 182KW cabinet, this rack requires external CDU (Cooling Distribution Unit) and heat rejection infrastructure (dry cooler or water tower). The rack manages power distribution and miner mounting; the CDU manages coolant circulation and temperature control. Confirm system configuration with MillionMiner sales. 65 x 110 x 235 cm.
Our mining specialists can help you find the perfect miner for your setup and budget.
Compact cabinet for 5 hydro miners at 85KW total capacity. The step between standalone 12KW radiators and the 28-miner industrial cabinet. 380V three phase with 225A main switch, triple 100A AC contactors, and 16-bit PDU at 16A x 3. DN40 main water pipe feeds DN8 single layer cooling lines per miner. 5 integrated protection functions and monitoring with online upgrade support. Requires external CDU and dry cooler for heat rejection. 65 x 110 x 235 cm. Compatible with Antminer and Whatsminer hydro series.
The step between standalone radiators and the 28-miner industrial cabinet. Centralized power, water, monitoring, and protection.
380V three phase, 225A main switch, triple 100A contactors. 35mm squared main cable. 16-bit PDU at 16A x 3. Built for 85KW total.
Integrated safety systems plus monitoring with online upgrade support. DN40 main pipe to DN8 per miner cooling lines.
Factory hydro ASIC miners from Bitmain and MicroBT. Compatible models based on Lianli's broader cabinet documentation: Antminer S19 Hydro, S21 Hydro, S21 XP Hydro, S23 Hydro, and Whatsminer M33S+, M53, M53S, M63 series. Confirm S23 Hyd 3U slot compatibility with MillionMiner given its different chassis format. Five miner slots total.
t 3 to 5 hydro miners. Managing 3+ separate radiators with individual coolant loops, power cables, and monitoring gets messy fast. The 85KW rack consolidates power distribution, water circulation, monitoring, and protection into one system. At 1 to 2 miners, radiators are simpler and cheaper. At 6+ miners, the 28-miner cabinet scales better.
Unclear from the MillionMiner listing. Like all Lianli cabinets, this rack requires external CDU and heat rejection (dry cooler or water tower) to function. The rack manages power and miner mounting; the CDU manages coolant. Contact MillionMiner through Get a Quote to confirm whether the listing covers the rack only or the complete system.
380V three phase industrial service. 225A main switch with three 100A AC contactors. 35mm squared main cable and 16mm squared branch cables. Professional electrical installation by qualified technician required. Not compatible with residential or standard commercial electrical service.
MillionMiner does not specify them individually. Based on Lianli's standard cabinet architecture across their product line, these likely include over temperature protection, over pressure protection, leak detection, over current protection, and coolant flow rate monitoring. Confirm specifics with MillionMiner sales.
DN40 is the main water pipe at approximately 40mm diameter, carrying total coolant flow for all 5 miners. DN8 is the single layer pipe at approximately 8mm diameter, delivering coolant to individual miner slots. The larger main pipe ensures adequate flow capacity; the smaller per miner lines maintain appropriate velocity and pressure per unit.
85KW rack: 5 miners, 65 x 110 x 235 cm, entry tier infrastructure, lower capital investment. 182KW cabinet: 28 miners across 7 layers, 100 x 80 x 230 cm, dual PDU at 1,200A, PLC remote monitoring via internet/APP, factory hydro only. The 85KW is the right choice for small to mid scale operations running 3 to 5 hydro miners. The 182KW is for industrial scale with 10+ miners.
Yes. The rack operates with 1 to 5 miners. Empty slots remain unused with their coolant lines closed. Operators commonly start with 2 to 3 miners and add units as capital allows. Power and cooling systems scale proportionally to actual load.
Only if you have three phase 380V electrical service, which most homes do not. The physical footprint (65 x 110 x 235 cm) fits in a garage or basement, but the electrical requirement limits home deployment to rare residential installations with industrial power service. Most operators deploy this rack in commercial mining facilities.
Different scale and architecture. The Bitmain Antrack V1 is a 24KW single to dual miner rack from Bitmain's own ecosystem. The Lianli 85KW handles 5 miners at higher total capacity with more robust power distribution. The Antrack fits tighter home or small facility deployments; the Lianli 85KW serves mid scale operations wanting a managed multi miner rack.